administration.fm
A31003-C1000-M101-1-76A9, 03/2016
OpenScape Desk Phone CP200/400/600, Administrator Documentation
235
Administration
Password
3.18.3
Audio Settings
The usage of microphone and speaker for speakerphone mode can be controlled by the ad-
ministrator.
Both microphone and loudspeaker can be switched on or off separately. By default, both micro-
phone and loudspeaker are switched on.
Administration via WBM
Speech > Audio Settings
Administration via Local Phone
The
DTMF playback
feature aims at the capability to play DTMF digits received using
coding (i.e. Rtp events) in the current active audio device (headset / loudspeaker /
handset).
3.19
Password
The passwords for user and administrator can be set here. They have to be confirmed after
entering. The default factory setting for the administrator password is "123456"; it should be
changed after the first login (see Change Admin and User password). The factory setting for
the user password is "not set", i. e. no password.
Usable characters are 0-9 A-Z a-z ."*#,?!’+-()@/:_
Default Passwords
•
Admin menu: 123456
•
User menu: no password
•
Factory Reset: 124816
•
Soft Restart: Press keys 1-4-7 simultaneously and enter Admin password.
•
Factory Reset: Press keys 2-8-9 simultaneously and enter Reset password.
|
--- Admin
|
--- Speech
|
--- Audio Settings
|
---
Disable microphone
|
---
Disable loudspeech
|
---
DTMF playback
Audio settings
Submit
Reset
Microphone ON-Loudspeaker ON
Mute Settings
DTMF playback
;