Installation
The SUPERVISOR I module is shipped in a NEMA 4X fiberglass enclosure. Wall mounting kits are available
in three different sizes complete with 4 M4x0.7x8mm machine screws. It is recommended to use one of
the available mounting kits to prevent damage to the enclosure.
Figure 1 - Dimensions
Mounting Kit
#-########
Small Brackets
#-########
Medium Brackets
#-########
Large Brackets
Unless requested at the point of ordering, the module shall not come pre-drilled for field connections.
The end-user should drill or punch entries as required in the sides, bottom or top of the enclosure and
use cable glands or conduit connections that meet the requirements of the appliance area classification.
INFORMATION
Zone 2 Area classifications require the use of cable glands
that meet the flameproof Ex ‘d’
requirements of IEC 60079-0.