FORCE 50
REV. 2.2 2021-02-04
7-13
UNIFIRE FORCE 50 Robotic Nozzle
Installation and setup manual
SOFTWARE & CALIBRATION
Set the nozzle minimum (Motor 6), just before mechanical stop.
This is effectively selecting the max spray angle, and here you can limit the maximum spray allowed.
Set nozzle maximum (Motor 6), just before mechanical stop.
This is effectively selecting the straight stream.
Here you can block the straight stream by setting the
Maximum to - say - 10 ° spray, and thereby avoid a straight steam.
This is useful when the required reach is short, and you want to avoid a hard-hitting straight steam all together.
17) Calibrate Motor 6 (jet/spray nozzle) as Motor 4 and Motor 5