 UM220-IV M0 User Manual 

 
 

Antenna gain 

15

30dB 

Physical Characters 
Dimension 

10.1*9.7*2.2mm 

Environment 
Operating Temperature 

 -40

 ~ +85

 

Storage Temperature 

-45

 ~ +90

 

RoHS 

Accord 

Input/output Data Interface 
UART 

1 UART, LVTTL. Baud rate 4800

115200bps 

GNSS Performance 
Frequency 

BDS B1: 

1561.098MHz

 

GPS L1 : 

1575.42MHz

 

TTFF 

Cold Start: 28s 
Hot Start: 1s 
Reacquisition: 1s 
AGNSS

1

: 4s 

Positioning accuracy 

2.0m CEP (dual-system horizontal, open sky) 
3.5m CEP (dual-system vertical, open sky) 

Velocity accuracy (RMS) 

 

0.1m/s (dual-system, Open sky) 

Sensitivity 

 

 

GPS 

Tracking 

-161dBm 

-161dBm 

Acquisition 

-146dBm 

-147dBm 

Hot start 

-154dBm 

-155dBm 

Reacquisition 

-157dBm 

-158dBm 

 

1PPS accuracy (RMS) 

20ns 

Data updating rate 

1Hz  

Data output 

NMEA 0183, Unicore Protocol 

 

1.3

 

Interface 

GNSS IC

SAW

TCXO

Battery

RTC

Crystal

RESET_N

UART

PPS

UM

2

2

0

-I

V

 

M
0

LNA

 

Figure 1-2 Structure Chart 

                                                      

1

 Assist date input 

BDS

Содержание UM220-IV M0

Страница 1: ...WWW UNICORECOMM COM INSTALLATION AND OPERATION USER MANUAL Data subject to change without notice Copyright 2009 2020 Unicore Communications Inc GNSS Positioning Module UM220 IV M0...

Страница 2: ...ces and does not represent a commitment on the part of Unicore Communication Inc No part of this manual may be reproduced or transmitted in any form or by any means electronic or mechanical including...

Страница 3: ...ers Structure of the Document This document includes the following Introduction Briefly explaining the functions performances and installing of the product Installation Contains the list of the produc...

Страница 4: ...ECHNICAL SPECIFICATIONS 5 3 1 ELECTRICAL SPECIFICATIONS 5 3 2 OPERATION CONDITION 5 3 3 DIMENSIONS 5 3 4 PIN DEFINITION TOP VIEW 6 4 HARDWARE DESIGN 7 4 1 DESIGN IN CONSIDERATIONS 7 4 2 AVOID POWER CO...

Страница 5: ...d used SMT pads to support fully automatic integration of standard discharge and reflow soldering especially suitable for low cost and low power consumption fields The radio equipment is in compliance...

Страница 6: ...ot Start 1s Reacquisition 1s AGNSS1 4s Positioning accuracy 2 0m CEP dual system horizontal open sky 3 5m CEP dual system vertical open sky Velocity accuracy RMS 0 1m s dual system Open sky Sensitivit...

Страница 7: ...ctrostatic discharge ESD may cause damage to the device All operations mentioned in this chapter shall be carried out in an antistatic workbench using both wearing an antistatic wrist strap and a cond...

Страница 8: ...e follow the steps below to install Step 1 Make sure to make full anti static measures such as anti static wrist strap grounding the workbench Step 2 Open the UM220 IV M0 evaluation kit Step 3 Select...

Страница 9: ...Vcc 2 8 3 3 3 6 V Peak current Iccp 37 mA Vcc 3 0 V Tracking average current IACQ 19 20 21 mA Vcc 3 0V Low level input voltage Vin_low 0 7 V High level input voltage Vin_high 1 2 V Low level output v...

Страница 10: ...View GND NC VCC_RF NC NC RXD TIMEPULSE GND TXD GND nRESET NC NC RF_IN NC V_BCKP VCC_IO VCC Top View 1 2 3 4 5 6 7 8 9 18 17 16 15 14 13 12 11 10 Figure 3 2 UM220 IV M0 No Name I O Electrical level De...

Страница 11: ...CC power off and then on the power off time must be more than 10ms Recommended in serial concatenated RX place 1K resistance TX concatenated 33 or 1 K resistance other need PIO concatenated 4 7K resis...

Страница 12: ...sensitive device dramatic changes in temperature will result in reduced performance keep it as far away from the high power high temperature air and heating devices as possible 4 2 Avoid Power Connec...

Страница 13: ...2 UM220 IV M0 Active Antenna Other than 3v Solution If UM220 IV M0 uses passive antenna the antenna is directly connected to RF_IN pin while VCC_RF can be suspended It should be noted that the use of...

Страница 14: ...UM220 IV M0 User Manual 10 UM220 IV M0 PC RS232 UART1 RS232 1 Figure 4 4 Connect COM to PC...

Страница 15: ...M0 module is packaged in vacuum sealed aluminum foil anti static bag with desiccant and moisture proof agent When using reflow welding process to weld modules please strictly comply with IPC standard...

Страница 16: ...m Carrier tape Space between 20mm Check the humidity indicator card before soldering The 30 indication is blue for normal conditions as shown in figure 6 2 Bake modules firstly before soldering if the...

Страница 17: ...the shielding shell causing mildew and other problems 8 Reflow Soldering In order to avoid device falling off the module should be placed on the top of the main board during welding Reflow soldering t...

Страница 18: ...UM220 IV M0 User Manual 14...

Страница 19: ...www unicorecomm com Unicore Communications Inc www unicorecomm com Phone 86 10 69939800 Fax 86 10 69939888 info unicorecomm com 7 F3 No 7 Fengxian East Road Haidian Beijing P R China 100094...

Отзывы: