18
Debug Support
UC-08-M34 EN R1.0
7
Debug Support
As mentioned above, TP1 and TP10 can be used to connect an external power to
supply VCCIN and V_BCKP and to measure the supply voltage and current.
TP2, TP4, TP5, TP6 and TP8 are used for internal debugging, of which TP6 and TP8
can be used to debug I
2
C.
J1 is used for MMCX connection. After soldering the MMCX connector, it can be
used to measure the PPS signals.
J2, J3, J6 and J7 are debug ports. Connect the signal that needs to be tested to the
square hole and test the round hole, or connect the round hole to a measuring
instrument. Using these debug ports can avoid damage to the PCB pads and traces,
which is convenient for debugging.
Debug1
Debug2
Debug3
Debug4
J1
NC
Figure 7-1 Debug Ports