background image

00333639 - 2

nd 

edition - 04/2011

ISTRUCTIONS FOR
INSTALLER, USER
AND SERVICE MAN

IDRONIK  TS 13

Instantaneous gas
water heater, type C.

88

Содержание IDRONIK TS 13

Страница 1: ...00333639 2nd edition 04 2011 ISTRUCTIONS FOR INSTALLER USER AND SERVICE MAN IDRONIK TS 13 Instantaneousgas water heater type C 88...

Страница 2: ...over to the user 3 1 5 Safety warnings 4 1 6 Data badge 5 1 7 General warnings 6 2 TECHNICAL FEATURES AND DIMENSIONS 7 2 1 Technical features 7 2 2 Dimensions 7 2 3 Main components 8 2 4 Operational d...

Страница 3: ...it is recommended to adjust the domestic hot water temperature as near as possible to the one you really require We recommend you to check the state of cleanliness of the heat exchanger at the end of...

Страница 4: ...loosening the screw pipe connections use only adequate fork spanners The improper use and or the use of inadequate equipment can cause damages for example water or gas leakages WARNING Indications fo...

Страница 5: ...ss A Features of the D H W circuit 7 Pn Nominal Output 8 Qmax Nominal max input 9 PW Max D H W Working Pressure 10 T max Max D H W Working Temperature B Electrical Data 11 Electrical supply 12 Electri...

Страница 6: ...or by means of the appropriate shutdown devices Do not obstruct the intake outlet terminal ducts In the event of failure and or faulty functioning of the appliance switch off the appliance Do not atte...

Страница 7: ...2009 142 EC ElectroMagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC 2 TECHNICAL FEATURES AND DIMENSIONS 2 2 DIMENSIONS COMPONENTS DESCRIPTION Two section burner Ultraflat...

Страница 8: ...imum Input Nominal Output Pn Minimum Output Efficiency at nominal load Efficiency at partl load Gas type Category Nominal gas feeding pressure Burner nozzle N Off Burner nozzle Smoke evacuation type k...

Страница 9: ...onstrictions and that no other appliance s flue outlets have been fitted unless the chimney is serving more than one heating appliance according to the specific standards and regulations in force The...

Страница 10: ...al duct Kit 60 100 for air intake and smoke eva cuation is packaged separate cardboard DO NOT DISPERS IN THE ENVIRONMENT A 430 mm B 755 mm C 230 mm 3 2 STANDARD CODES FOR INSTALLA TION IDRONIK TS is o...

Страница 11: ...hich could reach the water exchanger and affect the proper running of the water heater b Check that the appliance has been preset for operating with the gas type available This is verifiable via the i...

Страница 12: ...ce by device Check with the gas cock turned off that there are no gas leaks During the 2nd quarter of the hour from the start of the test no pressure reduction should be detected by the pressure gauge...

Страница 13: ...l the supplier s contractual or extra contractual responsibilities 3 8 ROOM VENTILATION The appliance has to be installed in a convenient room in conformity with the rules inforce and particularly bec...

Страница 14: ...allow to the outside the possible condensate Example 1 LATERAL AIR INTAKE SMOKE EVACUATION Example 2 REAR AIR INTAKE SMOKE EVACUATION pendenza 2 00262980 Coaxial kit 60 100 supplied as standard made o...

Страница 15: ...n correctly earthed in compliance with the regulations in force The gas and water feeding pipes cannot be used as ground plates Ensure that the above safety electrical requirements subsist in case of...

Страница 16: ...ure is 35 C the maximum settable temperature is 60 C adjustable 1 by 1 C Normally the outlet temperature of hot water is for a shower of about 40 C Adjust the hot water flow rate C up to the necessary...

Страница 17: ...ature through the button B according to your own needs It is good to get familiar with the appliance commands by repeating several times the ignition procedure after the installation or the first use...

Страница 18: ...ervice works have been done perform always the following operations Open the cold water inlet cock if previously closed Open the gas gate valve Switch on the electrical supply to the appliance and tur...

Страница 19: ...ulty gas valve Actions Check gas valve and its connec tions Effect STOP 6 ERROR CODES Maximum temperature ptotection Actions Control the circulation Effect STOP E3 E3 E3 E3 E3 Obstructed discharging s...

Страница 20: ...g info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold ne...