HP-OWER

 

6

 

4.4

 

REFRIGERANT SAFETY DATA SHEET 

Name: 

R410A (50% Difluoromethane (R32); 50% Pentafluoroethane (R125). 

RISKS INDICATIONS 

Major risks: 

Asphyxia 

Specific risks: 

The rapid evaporation may cause freezing. 

FIRST AID 

General information: 

Never give anything by mouth to an unconscious person. 

Inhalation: 

Move to fresh air. 

 

Oxygen or artificial respiration if necessary. 

 

Do not administer adrenaline or similar drugs. 

Eyes contact: 

Rinse carefully with water for at least 15 minutes and consult a doctor. 

Contact with skin: 

Wash immediately with plenty of water. 

 

Take off immediately the contaminated clothing. 

FIRE PREVENTION 

Extinguishing Media: 

Whatever. 

Specific risks: 

Increase in pressure. 

Specific methods:  

Use water spray to cool containers 

ACCIDENTAL RELEASE ACTIONS 

Personal precautions: 

Evacuate personnel to safe areas. 

 

Provide adequate ventilation. 

 

Use personal protective equipment. 

Environmental precautions: 

Evaporate. 

Cleaning method: 

Evaporate. 

HANDLING AND STORAGE 

Manipulation 

 

Action/technical precautions: 

Provide sufficient air exchange and/or suction in work places. 

Recommendations for safe use: 

Do not breathe vapors or aerosol. 

Storage: 

Close tightly and store in a cool, dry and well ventilated place. 

 

Store in original container. Incompatible products: explosive, flammable materials, Organic peroxide 

EXPOSURE CONTROL / PERSONAL PROTECTION 

Control parameters: 

AEL (8-h e 12-h TWA) = 1000ml/m³ for each of the two components. 

Respiratory protection: 

For rescue and maintenance operation in storage tanks use self-contained respirator apparatus. 

 

The vapors are heavier than air and can cause suffocation by reducing oxygen available for breathing. 

Eyes protection: 

Safety glasses. 

Protection of hands: 

Rubber gloves. 

Hygiene measures: 

Do not smoke. 

PHYSICAL AND CHEMICAL PROPERTIES 

Colour: 

Colourless. 

Odor: 

Light. 

Boiling point: 

-52.8°C at atmospheric pressure. 

Lighting point: 

It does not ignite. 

Density: 

1.08kg/l at 25°C. 

Solubility in water: 

Negligible. 

STABILITY AND REACTIVITY 

Stability: 

No reactivity when used with the appropriate instructions. 

Materials to avoid: 

Highly oxidizing materials. Incompatible with magnesium, zinc, sodium, potassium and aluminum. 

 

The  incompatibility  is  more  serious  if  the  metal  is  present  in  powdered  form  or  if  the  surfaces  were,  recently, 
unprotected. 

Decomposition products 

These products are halogenated compounds, hydrogen fluoride, carbon oxides (CO, CO2), carbonyl halides. 

Risks: 

 

TOXICOLOGICAL INFORMATION 

Acute toxicity: 

(R32) LC50/ inhalation /4 hours/on rat >760 ml/l 

 

(R125) LC50/ inhalation /4 hours/on rat >3480 mg/l 

Local effects: 

Concentrations substantially above the TLV may cause narcotic effects. 

 

Inhalation of decomposed products of high concentrations may cause respiratory failure (pulmonary edema). 

Long term toxicity: 

Did not show carcinogenic, teratogenic or mutagenic effects in animal experiments. 

ECOLOGICAL INFORMATION 

Global warming potential 

1730 

GWP (R11=1): 

 

Potential depletion 

Ozone ODP (R11=1): 

 

Disposal considerations: 

usable with reconditioning. 

 

Содержание HP OWER 60

Страница 1: ...User s and Installer s Manual 60 90 120 150...

Страница 2: ...L CONNECTIONS 11 5 7 1 Wiring terminal block 11 5 7 2 Removal of protective carter for models 120 and 150 12 6 START UP 13 7 SHUTDOWNS FOR LONG PERIODS 13 8 MAINTENANCE AND PERIODICAL CONTROLS 13 9 TE...

Страница 3: ...HP_OWER 3...

Страница 4: ...the manufacturer as an attachment to this manual The company is available to give any detailed information about this manual and to give information regarding the use and the maintenance of its own u...

Страница 5: ...86 CEE 2009 104 CE 86 188 CEE and 77 576 CEE directives Every employer shall implement such provisions and ensure that their workers to respect them We observe therefore that Do not tamper with or rep...

Страница 6: ...ml m for each of the two components Respiratory protection For rescue and maintenance operation in storage tanks use self contained respirator apparatus The vapors are heavier than air and can cause s...

Страница 7: ...t only by QUALIFIED PERSONNEL Before any operation on the unit make sure the power supply is disconnected WARNING MOVING PARTS RISK OF DEATH Disconnect the power supply and ensure that the fan is stop...

Страница 8: ...o not exceed the maximum head loss on the plant side please see the technical data given in the table of Paragraph 12 available pressure head WARNING Connect the pipes to the attacks by using always k...

Страница 9: ...WARNING The water on the charging topping up pipe must be suitably pre filtered from any impurities and suspended particles Make sure that you have installed a cartridge filter removable WARNING Befo...

Страница 10: ...ALVE FO INVERTING CYCLE LR LIQUID RECEIVER EEV ELECTRONIC EXPANSION VALVE FL FILTER M AXIAL FAN SE OUTDOOR AIR TEMPERATURE P CIRCULATOR ON BOARD UNIT IN WATER INLET TEMPERATURE OUT WATER OUTLET TEMPER...

Страница 11: ...witch connections altered or not properly made the guarantee will be invalidated WARNING The remote control panel is connected to the water chiller by means of no 4 wires having a 1 5 mm 2 section The...

Страница 12: ...eutral output of auxiliary electric heater for plant water 230V 50Hz 5A AEH Digital output DO3 230 Vac Phase output of auxiliary electric heater for plant water 230V 50Hz 5A SAN Analogue ST9 digital D...

Страница 13: ...terminate immediately WARNING The summer winter operating mode have to be selected at the beginning of the related season Frequent and sudden changes of this seasonal operating mode have to be avoided...

Страница 14: ...d discharge piping of the compressor are usually high Be careful when working near condensing coils The aluminum fins are very sharp and can cause serious injuries After the maintenance operations clo...

Страница 15: ...R410A R410A R410A Refrigerant quantity kg 1 55 2 10 3 65 3 90 Design pressure high low MPa 4 2 2 7 4 2 2 7 4 2 2 7 4 2 2 7 Hydraulic circuit Water flow rate 3 m3 h 0 99 0 99 1 56 1 56 2 13 2 13 2 44 2...

Страница 16: ...allation and maintenance Read precautions for installation and maintenance at specific chapters on user s and installation s manual PRODUCT FICHE HP_OWER for medium temperature application Tout 55 C S...

Страница 17: ...Tj bivalent temperature Pdh 4 2 kW Tj bivalent temperature COPd 2 73 Tj operation limit temperature Pdh 3 8 kW Tj operation limit temperature COPd 2 35 For air to water heat pumps Tj 15 C if TOL 20 C...

Страница 18: ...Tj bivalent temperature Pdh 7 2 kW Tj bivalent temperature COPd 2 73 Tj operation limit temperature Pdh 6 9 kW Tj operation limit temperature COPd 2 48 For air to water heat pumps Tj 15 C if TOL 20 C...

Страница 19: ...j bivalent temperature Pdh 9 2 kW Tj bivalent temperature COPd 2 69 Tj operation limit temperature Pdh 8 1 kW Tj operation limit temperature COPd 2 29 For air to water heat pumps Tj 15 C if TOL 20 C P...

Страница 20: ...Tj bivalent temperature Pdh 10 2 kW Tj bivalent temperature COPd 2 58 Tj operation limit temperature Pdh 9 4 kW Tj operation limit temperature COPd 2 21 For air to water heat pumps Tj 15 C if TOL 20...

Страница 21: ...Pd 3 50 Tj bivalent temperature Pdh 4 0 kW Tj bivalent temperature COPd 2 21 Tj operation limit temperature Pdh 3 6 kW Tj operation limit temperature COPd 2 00 For air to water heat pumps Tj 15 C if T...

Страница 22: ...Pd 3 26 Tj bivalent temperature Pdh 7 1 kW Tj bivalent temperature COPd 2 10 Tj operation limit temperature Pdh 6 8 kW Tj operation limit temperature COPd 1 99 For air to water heat pumps Tj 15 C if T...

Страница 23: ...OPd 3 56 Tj bivalent temperature Pdh 8 3 kW Tj bivalent temperature COPd 1 93 Tj operation limit temperature Pdh 7 4 kW Tj operation limit temperature COPd 1 69 For air to water heat pumps Tj 15 C if...

Страница 24: ...OPd 3 37 Tj bivalent temperature Pdh 9 3 kW Tj bivalent temperature COPd 1 78 Tj operation limit temperature Pdh 8 5 kW Tj operation limit temperature COPd 1 55 For air to water heat pumps Tj 15 C if...

Страница 25: ...cessary to refer always to the technical data label stuck on right side panel of the unit 12 HEAT PUMPS AVAILABLE HEAD PRESSURE Below the characteristic curves corresponding to Head pressure Water flo...

Страница 26: ...HP OWER 26 13 WATER PUMP CURVES 13 1 MODELS HP_OWER 60 90 13 2 MODELS HP_OWER 120 150...

Страница 27: ...lure in the case of insufficient water flow but it does not ensure the minimum flow rate required in order the unit can work properly Models HP_OWER 60 90 120 150 Cooling capacity for reference kW 5 3...

Страница 28: ...WFCF Water flow rate correction factor PDCF Pressure drops correction factor The water flow rate and pressure drop correction factors are to be applied directly to the values given for operation with...

Страница 29: ...HP_OWER 29 16 DIMENSIONS 16 1 MODELS HP_OWER 60 IN OUT 1 M 16 2 MODELS HP_OWER 90 IN OUT 1 M...

Страница 30: ...HP OWER 30 16 3 MODELS HP_OWER 120 150 IN OUT 1 M...

Страница 31: ...HP_OWER 31 17 WIRING DIAGRAMS 17 1 MODELS HP_OWER 60 90 Temp Sensor Heat Sink...

Страница 32: ...HP OWER 32 17 2 MODEL HP_OWER 120 Temp Sensor Heat Sink...

Страница 33: ...HP_OWER 33 17 3 MODEL HP_OWER 150 Temp Sensor Heat Sink CN604 CN607 DC DC1 DC2 DC DC1 DC2 20A 5mH Reactor...

Страница 34: ...perature sensors for the environment thermohygrometer analysis and manage the double set point for the radiant floor panel that use a dehumidification system The intuitive interface simplifies the use...

Страница 35: ......

Страница 36: ...s It also reserves the right to modify its products as deemed necessary or useful without jeopardising their essential features 46033 casteldario mantova italia tel 39 0376 57001 fax 39 0376 660556 in...

Отзывы: