background image

Override dA “drawer absent” error message:

Manual drawer mode:

Press all 3 bottom row buttons at the same time for 10 seconds.

Buttons flash 3 times to confirm.

Drawer icon flashes red.

EMPTY DRAWER WARNING IS DISABLED

Drawer MUST be emptied manually.

8 6

p e

Override PE “pod error” message:

Manual drink mode:

Press all 3 top row buttons at the same time for 10 seconds.

Buttons flash 3 times to confirm.

Screen shows 2 lines blinking. 

All drink buttons are lighted.

All drink buttons will work with or withpout a pod inserted. 

8 a

!

Emergency settings to allow operation if pod or drawer sensors are not working

--

Switch OFF to reset 

the machine to normal 

opation

Call for Service as soon as 

possible after making these 

changes!

Troubleshooting

Troubleshooting

Содержание Pony 2

Страница 1: ...Brew Espresso Steam Milk Empty Waste Drawer Daily Coffee Cleaning Steam Wand Cleaning Programming Messages Troubleshooting www unic usa com 2018 UNIC USA 2 4 E S E 7 gram pods v2 16 EN 11 18 ...

Страница 2: ...tart Brewing Empty Waste Drawer when full Start Steam Adjust Foam Setting OFF Power Switch ON no heat ON with heat 2 4 Start Water Tap Cup tray can be mounted in 3 positions Up Down Attached to drawer Hot Water Tap ...

Страница 3: ... 2 slots on top Place pod halfway in slot before releasing Double Shot See Next Page Open packet Take care not to tear the pod Select Short or Long pour Do not use misshapen or torn pods Place cup under spout on same side as pod Do not drop pod in from above the slot Do not force pod Brew Espresso Brew Espresso ...

Страница 4: ... pods so they are not crushed or damaged Open packets Take care not to tear the pods Do not use misshapen or torn pods Insert 1 pod into both slots on top Place pods halfway in slot before releasing Place cup s under spouts Do not drop pods in from above the slot Do not force pods Brew Espresso ...

Страница 5: ... Turn the adjusting collar to vary the amount of air in the milk More air Less air Remove the pitcher and wipe the wand and tip with a clean damp towel Press the Steam or the SteamAir Button ON then OFF to purge The SteamAir wand MUST be wiped and purged after each use to prevent milk build up Steam or Water leaking from the top of the wand No Foam in milk See Cleaning Section Steam Milk Steam Mil...

Страница 6: ...Steam Milk ...

Страница 7: ...creen displays dA drawer absent when drawer is removed Icon turns green when counter resets Replace drawer Drawer holds 45 spent pods Drawer icon turns red when full Screen also flashes dF Empty Waste Drawer Drawer Level Alerts Empty waste drawer when full Empty Waste Drawer Empty Waste Drawer ...

Страница 8: ...ach cycle No drinks can be made when the drawer is full Empty Waste Drawer Follow instructions on previous page 00 06 Drinks can still be made when the drawer icon is orange The drawer may be emptied at any time even before the full message appears The drawer counter re sets to green every time the drawer is removed for 8 seconds 1 Drawer Level Alert Empty Waste Drawer ...

Страница 9: ...out Install Funnel Insert one cleaning tablet into each holder Stretch the silicone around the edge of the tablet Properly attached tablet Attach Tablets Before Starting the Automatic Cleaning Cycle 1 Install the Spout Funnel 2 Load Tablets into the Cleaning Tablet Holders See next page to start the automatic cleaning cycle Daily Coffee Cleaning Daily Coffee Cleaning ...

Страница 10: ... and hold the cleaning button until cL appears on the screen The cleaning button starts flashing blue Carefully insert one cleaning holder with tab let into each pod slot Start Cycle Before starting cleaning see previ ous page for set up instructions See next page for final cleaning steps The full cycle takes 3 minutes Daily Coffee Cleaning Daily Coffee Cleani ng ...

Страница 11: ...hed the dF drawer full or PE pod error message flashes Empty and replace the waste drawer Remove the Cleaning Inserts Finish Cleaning Cycle Press either double drink button to clear the display 00 Ready Daily Coffee Cleaning Daily Coffee Cleaning ...

Страница 12: ...he cleaning cycle Operation is locked out after a pre set number of pods are brewed This is to ensure continued performance Each cleaning re set the counter The number can be changed in the programming section For low volume machines set the number lower so it will request a cleaning once a day Do not set the alert higher than 250 00 CL CL 1 9 CL Start Cycle 20 more drinks are possible when clean ...

Страница 13: ... Temperature Probe Clean the Steam Tip everyday or if steam leaks from the top of the wand The SteamAir Wand may be removed for cleaning if it has heavy milk build up Switch the machine OFF before removing the Wand Next Page Turn switch all the way to the left 2 clicks Steam Wand Cleaning Clean Steam Wand ...

Страница 14: ...ke sure the probe tip is pushed all the way down when reassembling Install Outer wand with probe Insert Temperature Probe into outer wand Wipe Temperature Probe Replace Steam Tip Steam Wand Cleaning Make sure all 12 steam tip holes are clear Clean Steam Wand ...

Страница 15: ...r Volume is reached Small Hot Water Set volume Large Hot Water Set volume Manual Steam Set Time 30 sec standard or 1 sec purge Auto shut off Steam Set Temperature Switch the machine OFF to save the values 2 clicks Wait 3 seconds Turn switch ll the way back ON 2 clicks All Buttons flash when programming is active STOP START Program Steam Hot Water Programming ...

Страница 16: ...Programming ...

Страница 17: ... buttons flash Press and hold the green drawer button for 3 seconds to start ee Each of the 4 single buttons needs to be programmed individually ee Program each button to the desired level using a pod Not just water The center double buttons are auto matically set from the single values ee Next Page Program Coffee Dose part 1 86 Programming ...

Страница 18: ...ired level is reached Repeat for the other 3 buttons No need to program the center buttons Set machine into programming mode See previous page 86 Place measuring cup under spout Press desired button to start programming ee START STOP Next Page Program Coffee Dose part 2 Coffee starts dispensing Programming ...

Страница 19: ...ch the machine OFF to save the values 2 clicks When finished Pro gramming press the stars key to exit 86 Wait 3 seconds Turn switch all the way back ON 2 clicks Save Exit Coffee Dose Programming Programming ...

Страница 20: ...nge Exhaust Eject delay Do Not Change Drawer capacity Do Not Change Mandatory Cleaning Default setting is 250 drinks Machine will lock out and require a cleaning Must be set for each group Dose Program coffee doses see previous pages Coffee Dose Level in the cup Cleaning Alert are the only user changeable sections 86 Next Page Set Mandatory Cleaning Alert Programming ...

Страница 21: ... at cL for Cleaning Warning and Press the stars button 25 16 Shows 250 drinks dot times ten Use the center cup buttons to adjust up or down shows 160 Press stars button to save el Switch the machine OFF to save the values 2 clicks Turn switch all the way back ON 2 clicks Wait 3 seconds Set Mandatory Cleaning Alert Programming ...

Страница 22: ...Programming ...

Страница 23: ...l Waste drawer full 45 pods Pod Error Pod insertion slots in top cover are blocked Cleaning Cleaning required pe e6 el 8a 8f Normal Operation ee 00 8e Dose Error Unable to measure water volume when brewing See troubleshooting section for details Next Page Messages Codes ...

Страница 24: ...leshooting section Filling Displays on startup See troubleshooting section Filling Error Water filling error 99 SteamAir milk temperature probe defective Call for Service Messages on Steam Hot Water display 99 fl See troubleshooting section for details fe Messages Codes ...

Страница 25: ...s completely closed Check that switch at rear of cover makes an audible click when top is closed Check thet the Switch Spacer Pad is in place Call for Service Orange button flashes number of drinks left before cleaning Red button No drinks possible machine must be cleaned Click Troubleshooting Switch Spacer Troubleshooting ...

Страница 26: ...pods See Empty Waste Drawer section Make sure drawer is pushed all the way in Check for an obstruction such as fallen pods behind the drawer Call Service if the message doesn t clear See the end of this section for a temporary override setting Troubleshooting Troubleshooting ...

Страница 27: ...are still in place Brush dirt off sensors just inside each side of pod slots Clean with a soft dry brush if possible Call Service if the message doesn t clear See the end of this section for a temporary override setting Or the corner of a dry paper towel Never Use Water to clean Troubleshooting Troubleshooting ...

Страница 28: ... sure that water to the machine is turned on Change water filters if they are clogged Run a cleaning cycle Call service if the message doesn t clear Troubleshooting G 1 Group 1 Displays briefly on startup Call for Service if message does not clear Troubleshooting ...

Страница 29: ...ror Steam Hot Water display 99 Make sure that water to the machine is turned on Change water filters if they are clogged Switch machine OFF and ON to reset Call for Service 99 SteamAir milk temperature probe defective Call for Service Troubleshooting fe and or Troubleshooting ...

Страница 30: ...1 Turn main power switch fully to the right Position 0 Full OFF position Position 1 Power with no heating used for servce Position 2 Power and Heating No Foam in Milk Steam Wand leaking from top Steam wand and steam tip may be dirty or clogged See Steam Wand Cleaning Section Troubleshooting ...

Страница 31: ...ntly push any remaining pods through to the drawer Carefuly remove as much of the pod as possible Wipe area with a damp towel Use your fingers to activate the goups with no coffee Run several cycles with no coffee to rinse groups Never pour water into the group Call for Service if these steps are unsuccessful Troubleshooting ...

Страница 32: ...ror message Manual drink mode Press all 3 top row buttons at the same time for 10 seconds Buttons flash 3 times to confirm Screen shows 2 lines blinking All drink buttons are lighted All drink buttons will work with or withpout a pod inserted 8a Emergency settings to allow operation if pod or drawer sensors are not working Switch OFF to reset the machine to normal opation Call for Service as soon ...

Страница 33: ...Parts Supplies Spout Funnel RB 1120 Silicone Tablet Holders RB 0100 Cleaning Tablets Cafiza 1 2 tabs 100 count Waste Drawer RB 1200 Steam Tip 25909 Cup Shelf RB 3066 Parts Supplies ...

Страница 34: ...www unic usa com 2018 UNIC USA ...