Unibrain Fire-i 530/550/630/830/850 Operation Manual
Page 37
3.9.7.
Trigger Mode 3
Not supported at Format 7 Mode
This is an internal trigger mode. The camera will issue a trigger internally and the cycle time is N times (parameter)
the cycle time of the fastest frame rate. The Integration time of the incoming light is described in the “Shutter”
register. A Parameter is required and shall be one or more (N>=1).
3.9.8.
Trigger Mode 4
This mode is the “multiple shutter preset mode”. The camera starts the integration of the incoming light from the
first external trigger input falling edge and exposes the incoming light at shutter time. Repeat this sequence for the
N-th (parameter) external trigger input falling edge and then finish integration. A parameter is required and shall be
one or more. (N >= 1).