38 UNIBLOC-PD Operation & Service Manual: PD200-576
5.2 Lubricants and Bearing housing Oil Specification
The
UNIBLOC-PD
pumps are factory shipped with synthetic oil from Royal Purples: Poly-Guard® FDA. The oil is FDA, OSHA
and CFR compliant.
Before checking the oil levels
DISENGAGE THE POWER SUPPLY TO THE MOTOR
.
Permanent lubricated bearing housings; Models 200-0 - 275
When checking the oil level in permanently lubricated bearing housings, the pump must be removed from the system as described
in section 4.5. After removing it, stand the pump on the front cover nuts so that the drive shaft points up. Remove the bearing
housing cover bolts and rotate the cover without sliding it off the drive shaft. One of the oils specified above must be added. Re
-
place the cover making sure the o-ring remains in its groove. Tighten the cover bolts. The pump is now ready to be installed in the
system. Refer to section 3.4 before starting the pump.
Non-Permanent lubricated bearing housings; Models 300-576
When checking the oil level in bearing housings that are not permanently lubricated, the pump must first be stopped. Remove the
oil level check plug. If oil does not come out of this hole, it must be added through the vent hole until it starts to do so. Reattach
the vent and oil plug and resume operation.
If filling bearing housing oil with rear cover removed, fill oil level to approximately 1/8” from completely submerging the pump’s
timing gears. Ensure oil has fully settled and all air pockets have been removed. Air pockets will bubble to the top and decrease
the oil level. Add additional oil to reach proper level and attached rear cover plate or flange.
Table 5.2.1 lists optional manufacturer and oil that may be used.
Table 5.2.2 list recommended fill volume
MANUFACTURER
LUBRICANT NAME
TEMP. RANGE, ºC (ºF)
Mobil
SHC 627
SHC 634
-23...121 (-10...250)
121...152 (250...305)
Exxon
Spartan EP 100
Spartan EP 150
-23...121 (-10...250)
121...152 (250...305)
Shell
Spirax S 75W90
-23...152 (-10...305)
Sentinel
S140
-26...288 (-15...550)
Sentinel (for Hot Oil Pump)
S-NT-AA-I250
-26...288 (-15...550)
Royal Purple
Poly-Guard® FDA
-26...165 (-15...330)
Table 5.2.1
UNIBLOC MODEL
APPROX. OIL CAPACITY, ml (oz.)
STANDARD BEARING HOUSING
COMPAC BEARING HOUSING
200-0, 200, 250, 275
50 (1.7)
300, 350
150 (5.1)
170 (5.8)
400,450
350 (11.8)
1065 (36)
500, 550, 575
1500 (50.7)
N/A
501, 551, 576
650 (20.3)
N/A
Table 5.2.2
ATTENTION
Содержание 54001010P20H6010T12E
Страница 42: ...42 UNIBLOC PD Operation Service Manual PD200 576 UNIBLOC PUMP ...
Страница 43: ...UNIBLOC PD Operation Service Manual PD200 576 43 UNIBLOC PUMP ...
Страница 44: ...44 UNIBLOC PD Operation Service Manual PD200 576 UNIBLOC PUMP ...
Страница 45: ...UNIBLOC PD Operation Service Manual PD200 576 45 UNIBLOC PUMP ...
Страница 46: ...46 UNIBLOC PD Operation Service Manual PD200 576 UNIBLOC PUMP ...
Страница 47: ...UNIBLOC PD Operation Service Manual PD200 576 47 UNIBLOC PUMP ...
Страница 48: ...48 UNIBLOC PD Operation Service Manual PD200 576 UNIBLOC PUMP ...
Страница 49: ...UNIBLOC PD Operation Service Manual PD200 576 49 UNIBLOC PUMP ...
Страница 50: ...50 UNIBLOC PD Operation Service Manual PD200 576 3 ...
Страница 51: ......
Страница 52: ......