background image

                                                                                                                Professional Thermal Imager User Manual 

18 

 

13.14 

About   

After entering the first-level menu on the Settings page, select "About"option and press "SET key" 

to enter the sub-menu of "Product Information". Then you can view product model, infrared resolution, 

hardware version, system version, SN, SD capacity and other related product information.     

     

 

14. SD Card 

The device supports microSD cards to store images. In order to prevent excessive image data 

from affecting the operating speed, should periodically copy backup data and clear the data in the card. 

In order to avoid data abnormalities caused by hot swap, do not remove or insert the SD card repeatedly. 

Try to remove or insert the SD card when it is powered off. If you remove the SD card when viewing or 

operating an image, the message "SD card is lost" will be displayed.       

 

15. Maintain 

Clean the structural housing with the damp cloth or weak soapy solution. Do not use the grinder, 

isopropyl alcohol or solvent to clean the lens/window of the instrument housing.     

16. Safety precautions 

In order to guarantee the accurate measurement results, please read the instructions carefully.   

Содержание UTi720E

Страница 1: ...UTi720E UTi730E Professional Thermal Imager User Manual ...

Страница 2: ...t negligence misuse modification contamination or abnormal operation or handling etc The Distributor shall not be entitled to give any other guarantee in the name of the Company If you need warranty service during the warranty period please contact the authorized service center nearby to obtain the product returning authorization information andthen send the product to the service center with the ...

Страница 3: ...11 11 Photo view and edit 11 12 Digital amplification fusion ratio adjustment 12 13 System setup 12 13 1 Camera mode 12 13 2 Units 13 13 3 Parameters 13 13 4 Alarm 14 13 5 QR CODE 15 13 6 Language 15 13 7 Date and time 16 13 8 Wi Fi 16 13 9 USB mode 16 13 10 Brightness 16 13 11 Automatic Shutdown 17 13 12 Factory reset 17 13 13 Formatting 17 13 14 About 18 14 SD Card 18 15 Maintain 18 16 Safety pr...

Страница 4: ...550 4 1022 UTi730E Mode Automatic gain Thermal imaging pixel 320 240 76800 IFOV 3mrad Focal length 4 0mm Sensitivity 65mK 25 Frame frequency 9Hz Precision 10 400 room temperature of 25 and 2 2 to take the maximum value Temperature measurement scale 40 400 40 752 UTi720E UTi730E Sensor Un cooled vanadium oxide Display resolution 640 480 Emissivity 0 95 default 0 01 1 00 Visible light pixel 2 millio...

Страница 5: ...Image browse Temperature analysis changingswatches and remarks QR code scanning Yes USB communication Type c USB Charging real time image and USB disk storage WIFI Yes PC projection screen Yes PC analysis software Yes live image photo download and analysis Mobile phone APP Yes Photo download and analysis LED lighting Yes Language English French German Spanish Russian Authentication CE FCC UKCA ROH...

Страница 6: ... browsing button 2 Upper casing 12 Back key 3 Lower casing 13 Right key 4 SD card slot 14 SET key 5 Interface protection cover 15 Down key 6 LCD display 16 Bracket fixed screw hole 7 Start key 17 Infrared thermal image window 8 Lighting key 18 Lamp 9 Left key 19 Visible light camera window 10 Up key 20 Photo trigger key ...

Страница 7: ...ement central point 4 Power on off Long press the Power button for 5 seconds to start up the thermal imaging device if start up the device just now the device is not being used for a long time or after the measurement environment changes it will take up 30 minutes for starting up the device to measure the temperature Long press the Power button for 5 seconds to turn off the thermal imaging device ...

Страница 8: ...e Settings 7 Press Back key again to return to the home page of thermal imaging Main menu Sub menu 6 Marking tool If you need to use the center point high low temperature tracking temperature display function press SET key to pop up the main menu options select Marking tool by using left right key and then press SET key to enter the marking tool sub menu options and make selection byusing left rig...

Страница 9: ...cture in picture mode you can change the position and size of the picture in picture by selecting Move or Stretch by using Left right key Press SET key to select QR code you can manually enter the QR code or scan the code to obtain QR code and select Cancel to return to the main page 8 Swatches switching Press the SET key to pop up the main menu options select Swatches Switch by using Left right k...

Страница 10: ...arison information will be displayed on the right after comparison and delete only the currently selected temperature measurement analysis object can be deleted After adding the temperature measurement analysis object the corresponding temperature information will be displayed on the left side When select the line temperature measurement analysis object the temperature curve of the line area will ...

Страница 11: ...sired vitta tool by using Left right key Six isothermal modes can be selected Auto isothermal Proportional isothermal Down isothermal Up isothermal Interval isothermal and Manual isothermal 11 Photo view and edit On the main page press the Photo view key to enter the multimedia view Press Up Down key to select all photos videos or other folders and press the SET key to enter Press Up Down Left Rig...

Страница 12: ...e new image will be added and back to view page After adding QR code press Back key and the message Save and exit will pop up to confirm then the added QR code will be saved If you select Cancel the QR code will not be saved and exit the QR code editing page For QR code added here it will not be saved to the existing QR code category If you need to modify the existing QR code just modify it in the...

Страница 13: ...s the SET key to enter the sub menu of Parameter Select emissivity ambient temperature reflected temperature relative humidity object distance Temperature scale through the Up Down key Press SET key to select the parameter you want to change and press Up Down key to select the value for the parameter When setting the object distance parameter press the SET key to enter the Object distance sub menu...

Страница 14: ...e for the parameter When setting the object distance parameter press SET key to enter the sub menu of Object distance and then use the SET key and the Up Down key to modify the parameters 13 4 Alarm After entering the first level menu on the Setting page select Alarm option press SET key to enter the sub menu of Alarm and select the high temperature alarm low temperature alarm LED alarm by using t...

Страница 15: ...ption and press SET key to enter the QR CODE sub menu Select different QR Codes by using Up Down key and press SET key to enter the change page for QR CODE name CODE 13 6 Language After entering the first level menu on the Setting page select Language option andselect English French German Spanish or Russian by using Up Down key ...

Страница 16: ... key 13 8 Wi Fi After entering the first level menu on the Setting page select Wi Fi option and press SET key to enter the sub menu Press SET key to open theHotspot press Down key to select the Hotspot ID and password and set up by using SET key 13 9 USB mode After entering the first level menu on the Settings page select USB mode option and press SET key to enter the Sub menu of USB mode Select U...

Страница 17: ...n of Factory reset option press SET key and the prompt Shutdown and factory reset will pop up If you select Yes the device will automatically shut down and the instrument will restore factory settings after manual startup 13 13 Formatting After entering the first level menu on the Settings page select the Formatting option and press the SET key If there is SD card the message format SD card will p...

Страница 18: ...operating speed should periodically copy backup data and clear the data in the card In order to avoid data abnormalities caused by hot swap do not remove or insert the SD card repeatedly Try to remove or insert the SD card when it is powered off If you remove the SD card when viewing or operating an image the message SD card is lost will be displayed 15 Maintain Clean the structural housing with t...

Страница 19: ...ts on temperature and humidity please see the product parameter table The system supports USB cable to charge the device but in order to improve charging efficiency it is recommended to remove the battery pack and charge the battery pack separately 17 FCC Compliance statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may n...

Отзывы: