     Please read the manual and “Safety Information” 

 and Warnings carefully before using the meter. 

Warning

UT204A is a 4000-count AC/DC digital clamp meter
with stable performance, high degree of safety and
reliability. It is designed with large-scale integrated 
circuits and dual integral A/D converter as its core, 
overload protection for all ranges and novel structure,
which make it a superb tool for electricians. The 
meter can measure AC/DC voltage, AC/DC current, 
resistance, diode, continuity, capacitance, frequency
and temperature, etc.

I.Overview

II. Unpacking Inspection

III. Safety Information

Please open the package box and take instrument 
out. Please check if following items are deficient or 
damaged or not.

1  pc
1  pair
1  pc

1. 

 

            

2.  Test Probes                        
3.  Temperature  probe    

4.  Guarantee  certificate  

1  pc

       Please contact your supplier instantly if any 

 

item is deficient or damaged.

    The instrument is designed and manufactured in 
compliance with GB4793, IEC61010-1 and IEC
1010-2-032: Double Insulation, Overvoltage CAT

600V & CAT

 300V and Pollution Degree 2.

      A Warning identifies conditions and actions that 
may pose hazards to the user, or cause damage 
to the Meter or equipment under test.  Please pay
 attention to      warnings and use the meter as 
specified as follows, otherwise the protection offered
by the clamp meter would be impaired.

1. Please inspect clamp meter and test leads before 
    use to avoid damage or abnormal use. Please 
    do not use the clamp meter again if test leads or 
    shell insulation is damaged obviously with LCD 
    display failure or clamp meter cannot operate 
    normally.
2. It is strictly prohibited to use clamp meter before 
    covering rear cover and battery cell to avoid 
    electric shock.
3. Fingers cannot exceed the finger guard of  probe  
    during measurement. Do not touch nude electric 
    wires, connector, unused input end or circuits 
    during measurement to avoid electric shock.
4. Function switch must be in correct position 
    before measurement. It is strictly prohibited to 
    change ranges during measurement to avoid 
    damage of clamp meter.
5. Do not exert more than 600V between terminal 
    of clamp meter and grounding to avoid electric 
    

    Shock or damage of clamp meter.
6. To operate the instrument carefully under DC 60V 
    or AC 30V to avoid electric shock.
7. Do not measure voltage or current which is more 
    than permissible input value. Be sure to place 

    function range switch to the maximum range 
    position if scope of measured value cannot be 
    determined. Be sure to cut off circuit power and 
    discharge all capacitors before measuring 
    of online resistance, diode or circuit. Disconnect 
    probe and measured circuit then remove probe 
     from input end of  clamp meter and cut off power 

     after measurement.

8.  Replace the battery when“     ” shows on the 

LCD to ensure the measuring accuracy.To

    take battery out if clamp meter has not been 
    used for a long time.
9. Please do not alter internal wiring of clamp meter 
    randomly to avoid instrument damage and safety 
    danger.
10.Do not store or use clamp meter in environment 
    of high-temperature, high-humidity, flammables, 
     explosives and strong current  magnetic Field.
11.Please clean the instrument shell by soft cloth 
    and neutral detergent during maintenance. Do 
    not use abrasive or solvent to avoid shell 
    corrosion which may cause any damage to the
    clamp meter or personal injury.

IV.Electrical Symbols

Double Insulated
AC
Diode
Warning prompt
AC or DC
To meet European Union standard.

Grounding
DC

 Low battery Indication

Buzzing ON/OFF

V.The Meter Structure (See Figure 1)

   

1. Input end;
2. LCD digit display;
3. Function key: To select basic functions;
4. Measurement function knob: White mark is 
    initially set value; Blue mark  is validated after 
    selecting blue key;
5. Clamp head trigger: To press 
   the trigger to loosen clamp 
   head. 

     

 Clamp head will be
       again  

 trigger;

6. Hand protection: It prevents
    users from touching any 
    dangerous area.

 

7. Clamp head: It is a device to

      convert current to  voltage. Single 

    conductor of measured current must pass through 
    center of clamp head perpendicularly;

1

2

5

7

6

4

3

Figure 1

tightened
if loosening the

 measure AC/DC current to 

VI.Display Symbols(See Figure 2)

3

4

6

10

11

13

12

5

8 9

15

1

2

16

7

14

Figure 2

1. Indicator for AC Measurement;
2. Indicates negative polarity;
3. Indicator for DC Measurement; 
4. Low Battery Indication;
5. under Auto-Ranging Mode;
6. Indicator for Diode Test;
7. Indicator for Continuity Test;
8. Indicator for Duty Cycle Test;
9. Data Hold is Active;
10. Indicator for Relative Measurement;
11. Temperature Unit (

);

12. Resistance Unit (

Ω, KΩ

 and M

Ω

);

13. Frequency Unit (Hz);
14. Capacitance Unit (nF and µF);
15. Current Unit (A);
16. Voltage Unit (mV and V)

VII. Key Functions and Automatic 
      Shutdown

1.HOLD

It is to maintain displayed reading by triggering. 
Displayed value will be locked for constant display 
by pressing the key once. It can be pressed again  
to release locking status and return to common 
measurement status. 

2.REL

3.SELECT

To switch over between 

Note: Automatic shutdown function will be 
cancelled  if pressing SELECT key to wake up 
the meter from the sleep mode.

4.Automatic Shutdown
Clamp meter will  power off automatically
(under sleeping status) to save electric energy if 
function key and knob switch fail to operate 
within 15 minutes during measurement.  Clamp 
meter will  start up automatically  (under 
working status) by rotating function key under 
automatic shutdown status. (Please refer to Item 
6 for effective key operation.)

Press down the key to use current reading as the
 reference value and reset the display to "0".  This
 reference value is subtracted every time from 
measuring results until you press the key again 
to exit the mode.

Note: Automatic shutdown function will be 
cancelled by pressing SELECT key for wake-up 
under sleeping status.

5.Buzzer

Buzzer will beep if pressing any effective function 
key under any measurement range. It will not ring 
if the key is invalid. Buzzer will issue 5 warning 
voices continuously about 1 minute before 
automatic shutdown. It also will issue a long-term 
voice before  power off.

6.Key validity

Not all keys are valid under any range. As indicated
below, corresponding functions or to wake up the
meter can be achieved only when the keys are valid.

K

ey

Hz

SELECT

N/A

N/A

N/A

REL

HOLD

VIII. Measurement Instructions

1. DC voltage measurement (     ) (See Figure 3)

    

    Warning: Clamp meter cannot be used for 

    conductive  object of which voltage exceeds 
    AC/DC 600V .

To set knob.
Please place function knob to 

 

To select key functions.
The clamp meter defaults at 
DC Voltage and auto-ranging 
mode. Press REL 

 to 

access relative mode. 

 

To connect load.

V

T o disconnect probe

and measured circuit then 

remove probe from input
end after all measurement 
operations.

Figure 3

2. AC voltage measurement (       ) (See Figure 4) 

  

    Warning: Clamp meter cannot be used for 
    conductive article of which voltage exceeds 
    AC/DC 600V

.

To set knob.

    Please place function knob to 

To select key functions.
Press SELECT button to 
select AC voltage  mode, 
 it defaults at auto
 -ranging.Press 
REL

 to access

 relative mode.

To connect load.

V

~

~

Figure 4

To disconnect probe and
measured circuit then 

remove probe from  
input end after all measurement operations. 

3. Resistance measurement (    )

    (See 

    Figure 5)

    Warning: Be sure to cut off circuit power and 
    discharge residual charge of all capacitors 
    before load connection.

To set knob.

    Please place function
    knob to  

To select key
 functions.

    It defaults at Ω 

    mode and in auto  
    -ranging.Press REL
 

 to access relative mode.

 

To connect load.

                

 

Figure 5

To gain excellent measured result by separating 

element from circuit.

T

o disconnect probe and measured circuit then 

remove probe from input end after all 
measurement operations.

4. Diode measurement (       )     

  (See Figure 6)

    Warning: Be sure to cut off circuit power and 
    discharge residual charge 
    of all capacitors before
   load connection.

To set knob.

    Please place 
    function knob to 

              

To select functions.
To select diode detection 

    by pressing SELECT key;

To connect load.

 

.

Figure 6

To gain excellent measured result by separating 
element from circuit.
To disconnect probe and measured circuit then 
remove probe from input end after all 
measurement operations.

5. Continuity Test (    )  

  (See Figure 7)

Warning: Be sure to cut off circuit power and 
discharge residual charge of all capacitors 
before load connection.

To set knob.

Please place function knob to 

                  

 

To select functions.

To select conductance detection by pressing 

SELECT key;

To connect load.

.

Figure 7

Buzzer will ring if 
measured resistance
 is less than 
10 . It can ring or 

not ring if measured 
resistance exceeds 10

.

To disconnect probe and 
measured circuit then 

remove probe from input 
end after all measurement operations.

6. Capacitance measurement (     ) (See 
    Figure 8)

Warning: Be sure to cut off circuit power and 
discharge residual charge of all capacitors 
before load connection.

To set knob.
Please place function knob to 

 

To select functions.
To select capacitance detection by pressing 
SELECT key;

To connect load.

Figure 8

Measurement notice:
1)Be sure to reset by
 pressing REL key 
 before measurement. 

    

2)Instrument reading will
  delay for about 30 
  seconds normally when 
  measuring large capacitance.

To disconnect probe and measured circuit then 

remove probe from input end after all 
measurement operations.

7.Frequency measurement (Hz) (See Figure 9)

Warning: Clamp meter cannot be used for 
conductive objecte of which voltage exceeds 
AC/DC 600V.
To set knob.

Please place function knob to  Hz

 

To select key functions.

To connect load.

Hz

Figure 9

To disconnect probe and
measured circuit then 
remove probe from
input end after all 

measurement 
operations.

Operating Manual