background image

UDP1306C

Model     

100V/120V         

220V/230V

UDP1306C      

T6.3AL/250V(20X5mm)    T3.15AL/250V(20X5mm)

<0.01%+3mV

<0.1%+3mA

<0

.

01

%+

5mV

<0.1%+10mA

10mV

1mA

<0.5%+20mV
<0.5%+10mA

10mV

1mA

2mVrms

3mArms

300ppm/

300ppm/

5.0V ±5%

2.0A

USB

3A

5mV

5%

Safety Information 

Important safety instructions must be followed for operating and storing the 
UDP1306C. To ensure your personal safety, read the following instructions 
carefully before operation to ensure that the UDP1306C is in the best working 
environment.

Program Control DC Power Supply
User Manual

Caution

Danger

High

 

Voltage

Ground

 

Terminal

Safety Guidelines 

General 

   

Do not block and isolate the air inlet and vent 

   

Avoid physical impact or using the instrument improperly 

   

Do not discharge static electricity onto the instrument 

   

Only professionals should open the instrument

AC Input

   

AC input voltage: 110V/120V/220V/230V, 50/60Hz 

   

Connect the protective ground wire to the earth to avoid shock hazard. 

Fuse Type

   

Corresponding fuse type for the model: 

   

Make sure to use the correct fuse type before starting up 

   

To prevent fires, only replace with fuses that meet the model and rating 

     value 

   

Do not connect the power cord before replacing the fuse to avoid electric 

     shock 

   

Confirm the cause of the blown fuse before replacing the fuse

Power Supply 

AC input voltage includes 100V/120V/220V/230V±10%, 50/60Hz. You can 
select different input voltages through the "AC SELECTOR" on the rear panel 
according to actual needs, please disconnect the power connection before 
switching the input voltage

UDP1306C

 

Program

 

Control

 

DC

 

Power

 

Supply

 

Introduction

The

 

UDP1306C

 

DC

 

power

 

supply

 

has

 

two

 

groups

 

of

 

independent

 

outputs

the

 

adjustable

 

output

 

of

 

32V

/

6A

which

 

has

 

the

 

constant

 

voltage

 (

CV

and

 

constant

 

current

 (

CC

modes

and

 

the

 

fixed

 

output

 

of

 

5V

/

2A

 

with

 

protection

 

features

 

of

 

short

 

circuit

 

and

 

overvoltage

UDP1306C

 

Main

 

Features

     

4

-

digit

 

voltage

 

and

 

current

 

  

high

 

precision

 

display

 

     

Overvoltage

,

overcurrent

 

and

 

  

over

-

temperature

 

protection

 

     

Output

 

voltage

/

current

 

settings

 

  

can

 

be

 

viewed

 

     

Remote

 

control

 (

output

 

ON

/

OFF

     

Shutdown

 

memory

 

     

Keypad

 

lock

 

     

Intelligent

 

temperature

-

controlled

 

fan

 

     

USB

 

phone

 

charging

 

interface

     

RS232

 

program

 

control

 

  

communication

     

USB

 

device

 

communication

     

5

 

sets

 

of

 

data

 

storage

1. Ch1output voltage adjustment knob
2. M1-M5 data storage button
3. CH1 output current adjustment knob
4. Buzzer switch
5. Keypad lock
6. OUTPUT button
7. Channel CV/CC indicator (green-CV, red-CC) 
8.Green channel binding post (ground) 
9. Black channel binding post (negative)
10. Red channel binding post (positive) 
11. Mobile phone charging USB interface (5V/2A) 
12.Power switch
13. Output power
14. Current
15. Voltage 
16. Product model: UDP1306C
17. Remote control switch
18. USB Device communication interface
19. RS232 communication interface
20. Power supply interface
21. Voltage selector
22. Power supply louver

Main

 

Index

 

Parameters

Test

 

conditions

Turn

 

on

 

the

 

device

 

for

 

30

 

minutes

 

at

 

temperature

 

25

℃±

5

Ch1
Output Voltage

Output Current

Technical

 

Index

0

-

32V

0

-

6A

Power

 

Supply

 

Regulation

Constant

 

Voltage

Constant

 

Current

Load

 

Regulation

Constant

 

Voltage

Constant

 

Current

Resolution 
Voltage

Current
Programming

 

Accuracy

Voltage

Current

Read

 

Back

 

Resolution

Voltage

Current
Ripple and Noise (5Hz-20MHz)

Voltage

Current
Temperature Coefficient

Voltage

Current

USB
Output Voltage

Output Current-limiting Protection

Current Regulation

Load Regulation

P/N:110401108815X