background image

Wire Colour

Function

Connect To

Red
Black
Yellow
Blue

Power
Ground
Pattern Selection
Synchronization

+12/24 VDC (Power)

-

 12/24 VDC (Ground)

- 12/24 VDC (Power)
Synchronization Wire from another Unit

1.0

   Pattern Selection

Tap Yellow wire to Ground (Black wire) momentarily

1.1

   Flash Patterns

2.0

   Synchronizing

All lights must be set to the same Flash Pattern before connecting 

synchronization (Blue) wires

ON - OFF Switches

 

can be used for Power (Red wire)

OFF - (Momentary)ON Switches

 can be used for pattern selection (Yellow wire)

-  All lights are set to secondary by default at factory.
-  One light in each group can be selected as the 

primary lamp

 and control the pattern

      change in all lights of the group.
-  To setup primary unit, connect the 

Pattern Selection (Yellow wire)

 to 

Ground (Black wire)

      for 5 seconds. The light will turn off and turn on again.

2.1

   Switches to Use

NOTE: Only E-7315 & E-736 & E-735 can be synchronized

INSTALLATION MANUAL

E-735AB & E-735AW

All lights must be set to the same Flash Pattern before synchronizing

NO.

Pattern

NO.

Pattern

SAE

1
2
3
4
5
6
7

8
9

10
11
12
13
14
15
16
17

Quad, Alternating
Double, Alternating
Triple, Alternating
Quad, Alternating
Double, Alternating Left/Right
Triple, Alternating Left/Right
Quad, Alternating Left/Right

Single, Amber
Triple, Amber
Quad, Amber
Quad, Amber
Pulse, Amber
Single, Blue or White
Triple, Blue or White
Quad, Blue or White
Quad, Blue or White
Pulse, Blue or White

SAE
SAE
SAE
SAE

Dual

Colour

Single

Colour

(Amber)

Single

Colour

(Blue

or

White)

Отзывы: