7.2.
Recommended Operating Conditions
Over operating free-air temperature range (unless otherwise noted).
Table 2. Recommended operating conditions
Parameters
Conditions
Min.
Typ. Max. Unit
Ta (Ambient operating temperature)
Free-air temp.
-40
25
70
°C
Supply voltage
PoE
*1
36
48
57
V
V2X antenna gain
5850-5925MHz
-
-
7.6
dBi
V2X sensitivity
PER
≤ 10%
-92
-
-
dBm
PER
≤ 10%,
-40 - +85 °C
-82
-
-
dBm
V2X maximum input level
PER
≤ 10%
-
-
-30
dBm
V2X adjacent channel rejection
-
13
-
-
dB
V2X non-adjacent channel rejection
-
29
-
-
dB
V2X output power
Spectrum mask
Class C
-
-
20
dBm
GNSS antenna gain
Antenna Gain
-
-
2.4
*2
2.85
*3
dBic
LNA Gain
*4
24
27
30
dB
GNSS sensitivity
Tracking
-162
-
-125
dBm
GNSS LNA bias
I
LNA
≤ 20mA
3.0
-
3.3
V
Note:
*1: Powered by an 802.3af/at PSE
*2: Measured at 1575MHz
*3: Measured at 1602MHz
*4: LNA fed with 3.0V
7.3.
Power Consumption
RSU-301(v2)/RSU-351 is an 802.3af PD (powered device) and should be powered with
an 802.3af/802.3at PoE PSE (power sourcing equipment).
Table 3: Power consumption
Condition
Power Consumption
Temp.
Power Source
Voltage (V)
Low
*1
Typical
*2
High
*3
25°C
802.3af PoE PSE
54.3
0.06A
(3.26W)
0.06A
(3.26W)
0.11A
(5.97W)
85°C
802.3af PoE PSE
54.3
0.07A
(3.80W)
0.07A
(3.80W)
0.12A
(6.52W)
Note:
*1: RX only
*2: TX @ 1% duty cycle (CH172, 20dBm, 6Mbps, 750B, 10Hz)
*3: