background image

   

 
 

 

ENGLISH 

GB 

INSTRUCTION MANUALFOR USE AND MAINTENANCE 

 

1 GENERAL SAFETY WARNING 

 

1.1

 

General safety  

 

DANGER  DIN  4844-W  8:  Improper  use 
may  lead  into  electric  shock.  When 
installing, please check that the pump is 
not  connected  to  the  electric  current 
network. 

 

DANGER DIN 4844-W 9: Advise that the 
improper  use  may  lead  into  heavy  risk 
for persons and things. In order to avoid 
seriously  injuring  individuals  it  is 
absolutely 

forbidden 

to 

manually 

inspect the suction hole when the pump 
is connected to the power supply. 

 

REMARK:  improper  use  may  cause 
damage to pump or installation. 

 

1.2

 

General safety 

 

 Pay attention to the working limits. 

Improper use may damage the pump and 
the  other  property  and  cause  injury  to 
people. 

 

 Users  must  observe  the  accident 

prevention  regulations  that  are  in  force 
in  their  countries  at  the  time,  use 
suitable  personal  equipment  such  as 
safety  shoes,  rubber  gloves,  goggles  and 
a helmet. 

 

 While repairing or maintaining  the 

pump,  disconnected  the  electric  supply, 
this avoid to have an accidental start. 

 

 When starting the pumps be careful 

not to be in contact with water. 

 

 Users  must  not  operate  any  work 

on the pump. Our company declines any 
responsibility due to inobservance of the 
instructions listed in this manual. 

 

 Use  is  allowed  only  if  the  electric 

system  is  in  possession  of  safety 
precautions  in  accordance  with  the 
regolations in force in the country where 
the products is installed. 

 

 As  additional  protection  against 

lethal  electric  shock,  install  an  high 
sensitivity differential switch (0,03A). 

 

 For  connection  to  the  mains  use  a 

multiple-pole  switch  with  at  least  3mm 
distance between contacts. 

 

 This  appliance  can  be  used  by 

children  aged  from  8  years  and  above 
and  persons  with  reduced  physical, 
sensory  or  mental  capabilities  or  lack  of 
experience  and  knowledge  if  they  have 
been  given  supervision  or  instruction 
concerning use of the appliance in a safe 
way  and  understand  the  hazards 
involved. 

 

 Children  shall  not  play  with  the 

appliance. 

 

 Cleaning  and  user  maintenance 

shall  not  be  made  by  children  without 
supervision. 

 

1.3

 

Workspace 

 

 The working area must be properly 

delimited  and  closed  off.  All  work  must 
be  carried  out  in  accordance  with  local 
regulations in force. 

 

 Be  sure  that  there  is  an  open  exit 

from  the  working  area  in  case  of 
emergency. 

 

 In  order  to  avoid  soffocation  and 

poisoning,  it’s  absolutely  essential  to 

ensure that there is a sufficent amount of 
oxigen in the working area and that there 
are no gas leaks. 

 

 If  any  work  using  welders  or 

electrical  equipments  is  required,  check 
to  be  sure  that  there  is  no  danger  of 
explosion. 

 

 

It’s forbidden to stay in the pump’s 

installation  area  while  the  pump  is 
running. 

 

1.4

 

RESPONSABILITY:  The  manufacturer 

does  not  vouch  for  correct  operation  of 
the  pump  if  they  are  tampered  with  or 
modified,  run  outside  the  raccomended 
work range or in contrast with the other 
instructions  give  in  this  manual.  The 
manufacturer  decline  all  responsibility 

Содержание SAL 35

Страница 1: ...SAL 35 40 45 MANUALE D ISTRUZIONE I OPERATING INSTRUCTIONS GB...

Страница 2: ...e in the country where the products is installed As additional protection against lethal electric shock install an high sensitivity differential switch 0 03A For connection to the mains use a multiple...

Страница 3: ...anufacturer to avoid impeller blockages In the SAL 35 self priming version the body pump must only be positioned with the suction and delivery upwards 4 TRANSPORT MANAGEMENT AND DISPOSAL 4 1 Transport...

Страница 4: ...The proper direction of rotation corresponds to the type of operation that ensures greater delivery Do not operate the pump in the opposite direction of rotation any longer than 2 3min 6 INSTALLATION...

Страница 5: ...of the pump component This operation is also raccomended in case of prolonged inactivity of the pump at normal temperature If the pump has been used with substances that tend to deposit rinse it afte...

Страница 6: ...Contact the supplier to replace it c Check the sense of rotation and eventually invert it 4 PUMP DOESN T STOP a The supply switch is defective a Replace it 5 INTERMITTENT OPERATION a The pump is partl...

Страница 7: ......

Страница 8: ...izzatore non deve eseguire di propria iniziativa alcun intervento Decliniamo ogni responsabilit nella mancanza dell osservanza di quanto riportato nel presente manuale L utilizzo consentito solamente...

Страница 9: ...Le elettropompa non deve funzionare in assenza di acqua per evitare il danneggiamento della tenuta meccanica L elettropompa non pu essere utilizzata in piscine stagni o bacini con presenza di persone...

Страница 10: ...po Y secondo la norma CEI EN 60335 2 41 pertanto eventuali danni richiedono la sostituzione e non la riparazione dello stesso Nel caso di danneggiamento del cavo di alimentazione esso deve essere sost...

Страница 11: ...lle prime fasi di funzionamento della pompa Le perdite dovrebbero risolversi nel giro di breve Qualora ci non accadesse consultare il capitolo 12 Possibili avarie motivi e soluzioni 7 2 Arresto Interr...

Страница 12: ...assistenza per la sostituzione c Verificare che il senso di rotazione sia rispettato ed eventualmente invertirlo 4 LA POMPA NON SI ARRESTA a L interruttore di alimentazione difettoso a Sostituire l in...

Страница 13: ...DIMENSIONS INGOMBRI CUNFIGURATIONS CONFIGURAZIONI...

Страница 14: ...40 230 50 60 220 1 1 6 3 1 4 40 32 22 10 0 SAL 40 400 mono 50 60 230 0 8 5 1 4 40 32 22 10 0 SAL 40 400 trifase 50 200 0 7 1 4 40 32 22 10 0 SAL 40 115 50 230 2 8 20 1 4 40 32 22 10 0 SAL 40 48 mono 5...

Страница 15: ...mpatibility Regulations 2016 RoHS WEEE REACH Harmonized Standards BS EN 60335 1 BS EN 60335 2 41 BS EN 55014 1 2 BS EN 61000 3 2 3 3 MAGIONE 03 02 2021 UMBRAPOMPE SRL Legal Representative GB CONFORMIT...

Страница 16: ...5 cm prevista la consegna in tutti i punti di vendita in modalit 1contro1 ovvero la consegna al rivenditore potr avvenire solo all atto dell acquisto di un nuovo prodotto equivalente in ragione di uno...

Отзывы: