14.Disposal 

Dispose of the element of the oil filtration system in accordance with the laws or 
regulations/ordinance specified by the local government.   
When disposing of the unit connected with a vacuum pump, which exhausts toxic 

gas to human body, consign disposal to a specialized processor.   

  Pump oil is hazardous as well as vacuum pumps, main bodies, and elements. 

 

15.Warranty 

(1)

 

The warranty period for this unit is valid for one year from the day of purchase; 
however, consumable parts are excluded. 

(2)

 

If failure occurs within the period of warranty in condition of normal pump operation, 
repair of the pump with no charge should be guaranteed.   

① 

Ambient temperature for operation:

       

     7 to 40

 

② 

Type of exhaust gas of vacuum pump and temperature:     Dry air  7 to 40

 

③ 

Used and operated in accordance with the instructions manual. 

(3)

 

These cases listed below should be repaired at your expense even within the 

 period of warranty.  

① 

resulted from natural disasters, earthquakes, or fires

 

 resulted from special ambient environment, such as brine damages,   
public nuisance 

③ 

resulted from condition of use which is contrary to the terms for use written on the 

instruction manual (ex., specifications, maintenance, or check-up).   

           

       

④ 

When our technical staff judged that it resulted from the use which is contrary to 

the terms of use for the unit.   

 

16.Finally 

This instructions manual is limited to general description for the unit; 
If there is any question or trouble, please feel free to contact and consult us for   
further assistance. 

 

 

 

 

Содержание UFO-003

Страница 1: ...ANUAL ULVAC KIKO Inc Important Before Operating the UFO 003 small size oil filtration be sure to read this instruction manual thoroughly to ensure efficient and safe operation Size or Specifications o...

Страница 2: ...ults from the pump being stopped for a long time 2 Foreign objects have built up in the circulator pump from circulating extremely contaminated oil 1 Rust tends to form while the circulating pump is s...

Страница 3: ...rved in this instruction manual and the warning labels on this product marks symbols are categorized as follows DANGER DANGER indicates major hazardous situations which present an immediate threat of...

Страница 4: ...e oil leakage or explosion WARNING Do not cut an element fiber nor process adhesives etc It will loose a fiber shape and will not function as the element WARNING If the fiber element got in your eyes...

Страница 5: ...tions for Operation Please observe the following conditions for storage installation and operation Ambient temperature and humidity during operation 7 40 C Temperature on the surface during operation...

Страница 6: ...or damages on the pump DANGER Do not give any outer pressure or not handle the element roughly It will cause deform due to a fiber shaping product DANGER Install the element on the main body tightly...

Страница 7: ...low system diagram P5 Installation P6 Preparation for Operation and Supplement P6 Operation P7 Shutdown P7 Maintenance Check P7 Replacement of Element P8 Oil Replacement of Vacuum Pump P9 Troubleshoot...

Страница 8: ...iltration Circulating Filtration type Capacity of Filtration 0 6 0 7 L min 50 60Hz Maximum capacity of water removal 300cc Water disposal precision below 100ppm Maximum acid neutralization ability 0 4...

Страница 9: ...Description of 3 ways valve Inlet side 3 way valve direction Refill port side Closed position Inlet port side Outlet side 3 way valve direction Upper side oil drain side Closed position Drain port sid...

Страница 10: ...4 3 Outside view Item No Name Filter case Element Housing head Pressure gauge Power switch Stage Inlet 3 ways valve Inlet Inlet port Outlet side 3 way valve Outlet Drain port plug...

Страница 11: ...port inlet side 3 ways valve outlet side 3 ways valve outlet inlet Drain port optional special adapter is required UFO 003 Type Oil filtration system How to connect with GLD series pump attachment hos...

Страница 12: ...t the unit to the oil rotary pump by following the procedure on Section 4 1 Install the attached hose nipple tubes into both the oil inlet and oil drain port of the GCD series 2 Connect the inlet to t...

Страница 13: ...1 Turn off the main switch 8 2 Close both the Inlet side 3 way valve and Outlet side 3 way valve neutral position The Inlet side 3 way valve faces upward the Outlet side 3 way valve places sideways C...

Страница 14: ...nded Due to its highly sophisticated assembly please contact ULVAC KIKO or our dealers for the overhaul 9 3 List of consumable supplies Name qty Element Pump connection hose O ring AS 238 O ring G 100...

Страница 15: ...t from the housing head 10 12 After cleaning the inside and outside of the housing area place a new element 10 13 Install the filter case and the hose 10 14 Install a plug to the drain port Be sure to...

Страница 16: ...Clean the pipe Piping Defect in piping Check the pipe and repair Pump lock Check the pump and repair Defect in rotor Repair the pump Defect in oil seal Repair the pump Circulating pump Defect in reli...

Страница 17: ...pump Valve Hose Special quality of material AS resin PE resin SUS stainless steel PE polyethylene BS brass FC 250 steel casing BS PVC 13 2 Anti solvent Anti chemicals summary No problem Caution Aceton...

Страница 18: ...ient temperature for operation 7 to 40 Type of exhaust gas of vacuum pump and temperature Dry air 7 to 40 Used and operated in accordance with the instructions manual These cases listed below should b...

Страница 19: ...Situation Abnormal Sound Wrong Pressure Malfunction Others Periodical Inspection Periodical Repair Others 2 What kind of gas the pump sucked Is the gas toxic Yes No The kind and name of the gas 3 How...

Отзывы: