RF Power Supply and Matching Box
4. Functions
19
4. Functions
This chapter describes the functions of each unit.
4-1. RF power supply
The RF power supply can be run locally by the control panel and it can be run remotely by an
external analog signal.
4-1-1. RF power supply part names and functions
Part names
Description
1. POWER switch
The switch to supply 400 VAC to the RF power supply. Voltage is supplied to
the RF power supply when the switch is in the top position. After shutting off
the breaker, wait 30 seconds or more before supplying the power again.
2. AC INPUT connector
Connect the power input cable.
3. RF OUT connector
The connector to output RF power.
4. MB-SIG connector
Connect the matching box with the MB
–SIG cable.
5. OSC connector
Connect when using external OSC.
6. INTERFACE
connector
Wire for external control. When not performing external control,
short pins 1-14.
7. Cooling water IN
The connector for cooling water input.
8. Cooling water out
The connector for cooling water output.
9. GND terminal
Connect to a Class A ground.
10. RS-232C
Not used.
M
A
D
E I
N
JA
P
A
N
OSC IN
MB-SIGNAL
INPUT
50/60Hz
INLET
OUTLET
GND
INTERFACE
RF OUT
3∅AC360-528V
RS-232C
2
3
4
5
6
7
8
9
10
TIME
LIFE
Vpp
OUTPUT
RF POWER CONTROLLER
ESC
ENT
ALARM
RESET
TARGET
OSC
Vdc
OP
MAIN
15kW RF GENERATOR
RFS-13150F
1
ON
OFF
PRESET
Figure 4-1 Parts layout drawing
Table 4-1 Part names
Содержание RFS-13100F
Страница 66: ...F Power Supply and Matching Box 58 Figure 8 1 RFS 13100F...
Страница 67: ...F Power Supply and Matching Box 59 Figure 8 2 RFS 13150F ESC ENT M8...
Страница 68: ...F Power Supply and Matching Box 60 M8 60Kg Figure 8 3 RFS 13200F...
Страница 69: ...F Power Supply and Matching Box 61 Figure 8 4 RFS 27400F...
Страница 70: ...F Power Supply and Matching Box 62 Figure 8 5 MBX 13100F...
Страница 73: ...F Power Supply and Matching Box 65 Figure 8 8 MBX 27400F 2 M6...