RF Power Supply and Matching Box
5. Operation
51
Fw
: 1000 V
Re
: 100 W
OSC. MONITOR
INTERNAL OSC
OSC. MONITOR
EXTERNAL OSC
OPTIME :
20
[h]
ARC COUNT
0
[CNT]
TARGET LIFE
[1]
197.5 / 0
[kW・h]
5-1-5. Measurement value display
1) VPP, VDC menu
If the up key is pressed while displaying the measurement screen in normal operation, the VPP and
VDC measurement display is shown, but only while pressed. Press the "ENT" key and the screen
display can be fixed as the VPP, VDC measurement display.
(Power settings screen)
2) Oscillator display menu
If the down key is pressed while displaying the measurement screen in normal operation, the
selected oscillator is shown, but only while pressed.
(Operating by internal oscillator)
(Operating by external oscillator)
3) Operation time display menu
If the left key is pressed while displaying the measurement screen in normal operation, the operating
time and number of arcing occurrences is shown, but only while pressed.
(Power settings screen)
The maximum cumulative value is 999999 [h], the maximum count is 9999 [CNT]
(The number of arcing occurrences is reset at next RF ON.)
4) RF output accumulation display menu
If the right key is pressed while displaying the measurement screen in normal operation, the RF
output cumulative value and the subtractive value are shown, but only while pressed.
(Power settings screen)
The maximum cumulative value is 999.9 [kW
·
h].