DC Power
【
DC-10/DC-20
】
5. How to Operate
32
5-1-2. Parameter tree in MENU screen
After that, carry out the operation using various buttons on the front panel.
For the menu hierarchy, see the parameter tree below.
SYTM
CNFG
ARC
HOST
OTHR
MARC
HARC
LEVL
DELY
USE
TIME
SHDN
JDGE
VLEV
ILEV
BPS
TERM
ADRS
IGV
Number of units used during M/S
Whether or not a ARC Delay is used
ARC DELAY time
Detection count
Voltage threshold
Current threshold
Ignition voltage setting
Detection time
: 1 ~ 12 [units]
:100 ~ 50000 [usec]
: ENABL / DISBL
: 1 ~ 10 [usec]
: 1 ~ 15 [CNT]
: 0 ~ 500 [V]
: 0 ~ 90 [A]
: 9600 / 19200 / 38400 / 57600 / 115200
: YES / NO
: 1 ~ 127
: 1 ~ 255 [msec]
Initial value : 9600 [bps]
Initial value : 26 / 30 / 56 / 70 [A]
Initial value : 150 [V]
Initial value : 10 [msec]
Initial value : 5 [CNT]
Initial value : 1 [usec]
Initial value : DISBL
Initial value : 150 [usec]
Initial value : 1
Initial value : 1
Initial value : NO
OSC
CONT
HARC interrupting time
: 0 ~ 500 [msec]
Initial value : 10 [msec]
SHDN
MODE
Arc parameter
: SETA / SETB
Initial value : SETA
SETP
CONT
MODE
LOCK
SET
UNIT
10KW
20KW
LIMT
POWR
VOLT
CRNT
Number of units used during M/S
: 1 ~ 12 [units]
Initial value : 1
Fixation of control mode selection
Initial value : NO
Output control mode setting
: POWER, VOLTAGE, CURRENT
Initial value : Conforming to I/O
Operation mode setting
:LOCAL, USER, HOST, HOST+
Initial value : USER
Output power limiting value
Initial value : 10 / 20 [kW]
Initial value : 800 / 1000 [V]
Initial value : 18 / 25 / 40 / 50 [A]
: 400 ~ 1500 [V]
Initial value : 1500 [V]
: 2 ~ 8 [%]
Initial value : 2 [%]
OSC unit setting
: NONE, A2K, A2K_K, A2K_LOWM,
A2K_SMA, MFU, MFU_HIGH, MFU_SOFT,
MFU_SMA
Initial value : NONE
ACSW
Whether or not a LARC switch is used
Initial value : ENABL
: YES / NO
:ENABL / DISBL
MONI
FUNC
WARN
FAIL
BUS
SERV
HARD
CHCK
W / F
ARC
CONT
DISP
Setting ARC Detection Count Display
RAMP
USE
TIME
STRT
Whether or not a ramp is used
: DISBL / ENABL
Initial value : DISBL
Ramp Time
Initial value : 0.05 [s]
Whether or not a ramp is used
Initial value : 0 [%]
Machine number of the unit
Display of CHECK SUM value
RTC
Current time setting
OTHR
MENU
: 0.05 ~ 600 [s]
: 0 ~ 100 [%]
MARC interrupting time
Output voltage limiting value
Output current limiting value
Set point setting
Communication rate setting
Termination resistance setting
Address setting
Display of WARNING history
Indication of integration ARC count
Display of ERROR history
BUS voltage display
Figure 5-1
DC-10/20 Parameter Tree