Section 4 Equipment Installation, Piping, and Wiring
compressor and then turn the rotating part of the plug to the right. Turn it until it
won’t turn any more to connect the plug properly.
HELIUM SUPPLY FLEXIBLE HOSE
HELIUM RETURN FLEXIBLE HOSE
REFRIGERATOR POWER CABLE
RETURN GAS SUPPLY GAS
RETURN
SUPPLY
COOLING WATER
IN
OUT
NO.1
Figure 4-5
Connections of the compressor and single cryopump
4.5 Multiple cryopump installation
Figure 4-6 shows the connection of the compressor and multiple cryopumps.
1.
First, install helium manifolds to the compressor connectors to connect multiple
flexible hoses.
Refer to “Section 4.3 Connecting and disconnecting helium flexible hoses” for the
method of installing manifolds as it is the same as connecting flexible hose to the
compressor.
Connect flexible hoses to manifolds and to the refrigerators.
2. Connect the refrigerator cables from the rear panel of the compressor to the multiple
cryopumps.
ULVAC CRYOGENICS INCORPORATED