5.2 Gap/Black Mark Calibration, Self-test and Dump Mode
While calibrate the gap/black mark sensor, printer will measure the label length, print the internal
configuration (self-test) on label and then enter the dump mode.
To calibrate gap or black mark sensor,
depends on the sensor setting in the last print job.
Please follow the steps below to calibrate the sensor.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED
becomes red and blinking.
The LED will be changed as following order.
red (5 blinks)
red (5 blinks)
red (5 blinks)
red (5 blinks)
green (5 blinks)
green (solid)
4. It calibrates the sensor and measures the label length and prints internal settings then enter the dump
mode.
Note:
Please select gap or black mark sensor by Diagnostic Tool or by GAP or BLINE command prior to
calibrate the sensor.
For more information about GAP and BLINE command, please refer to TSPL2 programming manual.