63:
63 Sector Mapping will be performed. This option is used when the drive
has over 1024 cylinders and less than 528MB capacity. This option allows
users to get around the 1024 cylinder AT system BIOS limitation and
utilize the full capacity of the drive (up to 528 MBytes). This option must
be turned on for any drive with more than 63 sectors per track.
Track Mapping:
NO:
No Track Mapping will be performed.
≤1.2GB:
Track Mapping is performed to overcome the AT interface limitation under
DOS of 528MB and the drive connected is above 528MB and under
1.2GB. With this option, the user will be able to use drives that are greater
than 528MB without any third party software. This cannot be used under
Novell, or Unix/Xenix operating systems. UltraStor provides a device
driver for OS/2 (See Appendix F).
>1.2GB:
Track Mapping is performed to overcome the AT interface limitation under
DOS of 528MB and when the connected drive is over 1.2GB. With this
option, the user will be able to use drives that are greater than 528MB
without any third party software. This cannot be used under Novell, OS/2,
or Unix/Xenix operating systems.
1024 Cyl Truncation:
NO:
1024 Cylinder Truncation will not be performed.
YES:
Cylinder number will be truncated to 1024 to allow operating systems that
cannot use Track Mapping to overcome the 1024 cylinder limitation. This
is used in OS/2 applications to achieve a maximum of 528MB drive
capacity. UltraStor's OS/2 device driver (available through distributors) will
be needed to achieve more than 528MB disk capacity.
4.1.2 Hard Disk Drive Preparation Menu
Once the drive parameters have been set up according to the instructions in Section
4.1.1 above, the drive is ready to be low level formatted according to the following
procedure:
a. After system bootup is complete from drive "A" (DOS System disk is in
drive A), load
DEBUG
program (or SID for DR DOS) from floppy drive
"A" by typing:
DEBUG
after the
DOS
prompt "A" sign
b. Once in the
DEBUG
program, following the prompt "-" sign, type the
Page 12
Reference Manual
Содержание ULTRA 12F
Страница 1: ...ULTRASTOR CORPORATION ULTRA 12F24 ESDI CONTROLLER INSTALLATION MANUAL REVISION A 4 1 92...
Страница 2: ......
Страница 22: ...This Page Left Intentionally Blank...
Страница 28: ...This Page Left Intentionally Blank...
Страница 38: ...This Page Left Intentionally Blank...
Страница 44: ...This Page Left Intentionally Blank...
Страница 46: ...This Page Left Intentionally Blank...
Страница 48: ...This Page Left Intentionally Blank...
Страница 49: ...NOTES...
Страница 52: ...ULTRASTOR CORPORATION...