Additional expenses including international shipping and related customs paperwork, 

overnight and special shipping methods requested by the customer will be charged to customer.  

 

All refused and/or unpaid repairs are the responsibility of the customer and will be subject to the UPC 60 day “Must 

Claim” Policy. All products not claimed after 15 calendar days following repair will be subject to a storage fee 

beginning on the 16

th

 workday. The fee will be US$50 per day. After 90 calendar days, the product will be 

considered abandoned and UPC will take possession of abandoned property with intent to recover its costs for repair 

and storage.   Once UPC has taken possession of said abandoned property, UPC shall be entitled to sell the 

abandoned property and retain all funds received from said sale.  Funds received shall be applied to the customer’s 

outstanding balance.  

 

Packaging  

Generator shipments to UPC must be shipped in their original shipping containers or other solid and durable 

shipping containers of comparable size and composition.  DO NOT use Styrofoam peanuts or shredded paper for 

packaging material as this may cause damage to the electronic or mechanical components. Failure to comply with 
these packaging requirements may invalidate the Warranty. 

Assure RMA # is prominently displayed on the 

outside of the shipping package. Packages without RMA # on the outside will be refused. 

Cleaning Fee May be Assessed:  

Important:

 UPC does not have environmental permits or the facilities to address cleaning materials/contaminants 

remaining in the cleaning systems/tanks/consoles. Prior to returning equipment to UPC, de-contamination of 

equipment must be completed. UPC reserves the right to refuse acceptance of equipment. A $95/hour “Cleaning 

Fee” will be assessed for the cleaning of equipment that is considered by UPC to be excessively dirty/unclean.  

 

OEM Warranty Replacement / Repair Policy 

All service requests from customers of OEMs must originate their service request through the OEM. It is the OEM’s 

responsibility to obtain a valid UPC RMA number on behalf of their respective customer. 

No equipment from an 

OEM’s customer will be accepted at the UPC dock without a UPC issued RMA number.  

An RMA number 

must be requested from UPC by the OEM.  UPC will not provide RMA numbers to an OEM’s customer/end 

users.

 

Safety, Health and Environment Notice  

To inform and protect UPC personnel, applicable Safety Data Sheet (SDS) from the customer/end user must be sent 

with returned equipment.  Tanks, immersibles or other equipment will be held in an isolated area until applicable 

SDS are received and reviewed. UPC reserves the right to refuse product based upon failure to provide a SDS or 

based upon the information contained therein. Servicing may be denied and/or delayed without applicable SDS.   

Business Information and Return Information 

As indicated above, all product returns for service must have an RMA number prior to shipment to UPC.  Product 

without an RMA number will be refused.  Please ship, with shipment costs pre-paid to:  

Ultrasonic Power Corporation 

Attn: RMA Coordinator 

239 East Stephenson Street 

Freeport, Illinois 61032, USA  

+1 800-575-0168   

+1 815 235 6020  

Содержание BT H Series

Страница 1: ...22 Publication Number UPC220509 002 1 Benchtop H Series System Manual Ultrasonic Power Corporation 239 E Stephenson Street Freeport IL 61032 U S A Phone 815 235 6020 1 800 575 0168 Fax 815 232 2150 Em...

Страница 2: ...take some time to familiarize yourself with this manual and all aspects of the system configuration prior to start up We know that your Ultrasonic Power Corporation cleaning system will serve you for...

Страница 3: ...nings 4 1 Specifications 8 2 Principles of Operation 20 3 Operating Instructions 21 4 Inspection and Maintenance 26 5 Troubleshooting 28 6 Component Repair and Replacement 29 7 Diagrams and Drawings 3...

Страница 4: ...rsonal injury or death Warning The WARNING symbol means that failure to follow this safety statement MIGHT result in personal injury or death Caution The WARNING symbol means that failure to follow th...

Страница 5: ...n and damage delicate components CAUTION Incorrect voltage can damage the generator Do not operate the equipment unless the correct voltage is available Contact the proper authority about necessary ch...

Страница 6: ...Do not carry on conversation or permit yourself to be distracted in any manner while servicing live equipment Never service live equipment unless someone else is in the same room with you Never turn...

Страница 7: ...cted by splashing water and debris to a rating of IP 23 This system contains one power cord that is required to be attached to a properly rated three wire fusible disconnect with a grounding connectio...

Страница 8: ...tts Generator Operating Frequency 40 kHz Heater Power 500 Watts Estimated Heat Up Time 0 75 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate w...

Страница 9: ...nerator Operating Frequency 40 kHz Heater Power 500 Watts Estimated Heat Up Time 0 75 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight...

Страница 10: ...Generator Operating Frequency 40 kHz Heater Power 500 Watts Estimated Heat Up Time 2 5 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight...

Страница 11: ...erator Operating Frequency 40 kHz Heater Power 500 Watts Estimated Heat Up Time 2 5 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight Su...

Страница 12: ...erator Operating Frequency 40 kHz Heater Power 500 Watts Estimated Heat Up Time 2 4 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight Su...

Страница 13: ...erator Operating Frequency 40 kHz Heater Power 1000 Watts Estimated Heat Up Time 2 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight Sub...

Страница 14: ...Generator Operating Frequency 40 kHz Heater Power 1000 Watts Estimated Heat Up Time 2 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight...

Страница 15: ...enerator Operating Frequency 40 kHz Heater Power 1000 Watts Estimated Heat Up Time 2 1 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight...

Страница 16: ...enerator Operating Frequency 40 kHz Heater Power 1000 Watts Estimated Heat Up Time 2 7 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight...

Страница 17: ...enerator Operating Frequency 40 kHz Heater Power 1500 Watts Estimated Heat Up Time 2 6 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight...

Страница 18: ...enerator Operating Frequency 40 kHz Heater Power 1500 Watts Estimated Heat Up Time 2 8 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate weight...

Страница 19: ...tts Generator Operating Frequency 40 kHz Heater Power 1500 Watts Estimated Heat Up Time 4 9 hours Maximum dB level 85 dB Maximum Operating Temperature 180 F Dependent on selected options Approximate w...

Страница 20: ...ic Power Corporation utilizes our 5300 5400 series generators 2 Vibra bar transducer technology to convert electrical energy received from the generator into mechanical energy a Transducers fall into...

Страница 21: ...cleaner to operate properly and may damage the system 4 Plug the generator power cable into the appropriate voltage outlet Using incorrect voltage will not allow the cleaner to operate properly and ma...

Страница 22: ...rate recommended by the detergent manufacturer After cleaning one or two items you may choose to increase the chemical ratio The amount of chemical will be based on the condition of the water being u...

Страница 23: ...F while the timer is running will stop the timer and cause it to reset While the timer is running the ultrasonic generator will be turned on The default units for the timer is Hours Minutes 3 Run Mod...

Страница 24: ...acts the part s surface It may be necessary to rotate the part while submersed to allow air to escape Some initial testing will help determine the proper settings for the optimum time and temperature...

Страница 25: ...turn OFF the main power switch On the tank turn OFF the main power switch 3 4 Filter Operation Optional Accessory 1 Turn ON the main power switch 2 Press the filter system button to turn it ON Allow...

Страница 26: ...floor c If applicable make sure the castors are locked in place to prevent movement of system during operation d If applicable be sure all side panels are in place on the system NOTE All side panels m...

Страница 27: ...ORD FROM WALL RECEPTACLE BEFORE PERFORMING ANY PREVENTATIVE MAINTENANCE FUNCTIONS WITHIN ANY COMPARTMENTS ELECTRICAL SHOCK CAN CAUSE SERIOUS INJURY Recommended maintenance cycle is 3 months 1 Wash tan...

Страница 28: ...cord b Building power supply c Unit s fuses d Loose disconnected wires e Switches PROBLEM ITEMS TO CHECK 2 The ultrasonics do not work a Building power supply b Unit s fuses c Loose disconnected wires...

Страница 29: ...OLLOWING PRECAUTIONS WHEN WORKING ON THE EQUIPMENT 1 NEVER REACH ACROSS A SYSTEM WHICH HAS NOT BEEN TURNED OFF THE PLUG PULLED AND THE HIGH VOLTAGE CAPACITORS DISCHARGED 2 WHEN SERVICING LIVE ELECTRON...

Страница 30: ...Check for loose connection of wires 4 Check supplied power for correct voltage specifications 5 Test generator by turning the system on 6 If generator does not work contact Ultrasonic Power Corporatio...

Страница 31: ...h the system tank 4 Check for loose or damaged wires If damage is visible contact Ultrasonic Power Corporation service department for repair or replacement 6 5 PUMP FILTER PRE STRAINER 1 Remove power...

Страница 32: ...ransparent pre strainer and remove contaminants from mesh screen Return screen to pre strainer Ensure washer is seated properly Hand tighten pre strainer back in place Return pre strainer valve to ON...

Страница 33: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 33 7 Diagrams and Drawings 7 1 BT 1206H Drawings and Schematics BT 1206H Standard Drawing...

Страница 34: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 34 BT 1206H Standard Schematic...

Страница 35: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 35 7 2 BT 60H Drawings and Schematics BT 60H Standard Drawing...

Страница 36: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 36 BT 60H Standard Schematic...

Страница 37: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 37 7 3 BT 3606H Drawings and Schematics BT 3606H Standard Drawing...

Страница 38: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 38 BT 3606H Standard Schematic...

Страница 39: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 39 7 4 BT 4208H Drawings and Schematics BT 4208H Standard Drawing...

Страница 40: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 40 BT 4208H Standard Schematic...

Страница 41: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 41 7 5 BT 6006H Drawings and Schematics BT 6006H Standard Drawing...

Страница 42: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 42 BT 6006H Standard Schematic...

Страница 43: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 43 7 4 BT 2412H Drawings and Schematics BT 2412H Standard Drawing...

Страница 44: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 44 BT 2412H Standard Schematic...

Страница 45: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 45 7 7 BT 130H Drawings and Schematics BT 130H Standard Drawing...

Страница 46: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 46 BT 130H Standard Schematic...

Страница 47: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 47 7 8 BT 3612H Drawings and Schematics BT 3612H Standard Drawing...

Страница 48: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 48 BT 3612H Standard Schematic...

Страница 49: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 49 7 9 BT 330H Drawings and Schematics BT 330H Standard Drawing...

Страница 50: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 50 BT 330H Standard Schematic...

Страница 51: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 51 7 8 BT 3624H Drawings and Schematics BT 3624H Standard Drawing...

Страница 52: ...Property of Ultrasonic Power Corporation 2022 Publication Number UPC220509 002 52 BT 3624H Standard Schematic...

Страница 53: ...ty or to meet any liability which may arise by reason of any defect in such Third Party Product UPC HEREBY DISCLAIMS ANY WARRANTY EXPRESSED OR IMPLIED FOR FITNESS OF PARTICULAR PURPOSE OR OTHERWISE FO...

Страница 54: ...unty of Winnebago State of Illinois c This Warranty constitutes the entire understanding between the parties with respect to the subject matter discussed herein and supersedes any prior discussions ne...

Страница 55: ...C policy for the repair of equipment Payment confirmation pursuant to the quote provided by UPC must be received prior to any repair being made The initial diagnostic fee charged covers all testing di...

Страница 56: ...e of the shipping package Packages without RMA on the outside will be refused Cleaning Fee May be Assessed Important UPC does not have environmental permits or the facilities to address cleaning mater...

Страница 57: ...ensure that the power has been disconnected and that the liquid has been entirely drained from the system prior to movement Wipe down the system to remove all excess liquid Wrap up the power cable to...

Страница 58: ...for Immersible Transducers Comments Warranty Repair 0 00 UPC Warranty Applies Test Evaluation Fee 150 00 Waived with warranty replacement due to defect NON Warranty Quote Expired warranty equipment m...

Страница 59: ...onic Power Corporation 2022 Publication Number UPC220509 002 59 From RMA Ship To Ultrasonic Power Corporation 239 East Stephenson Street Freeport IL 61032 Attention RMA Coordinator cut here FRAGILE EL...

Страница 60: ...les 240V 1000W 50 34 070 20 20 Micron filter 50 70 734 10 20 Micron filter 50 70 584 T strainer 50 70 835 O ring for filter housing 50 40 139 20 Filter Housing 50 70 816 10 Filter Housing 50 70 769 Ga...

Отзывы: