OPERATIONAL & INSTRUCTION 

MANUAL 

 

Model:  6000FLT 

(220v-240V 3Ø) 

 
 

Voltage Supply to Machine:  

 
 

L1 to L2: ___________ L1 to Ground: ____________ L2 to Ground ___________ 

 
 

UltraSonic LLC

 

1200 Ferris Road

 

Amelia, Ohio 45102

 

 

Tel:  513-502-9746

 

Fax: 513-436-1527

 

 

[email protected] 

 

www.ultrasonicllc.com 

Содержание 6000FLT

Страница 1: ...LT 220v 240V 3 Voltage Supply to Machine L1 to L2 ___________ L1 to Ground ____________ L2 to Ground ___________ UltraSonic LLC 1200 Ferris Road Amelia Ohio 45102 Tel 513 502 9746 Fax 513 436 1527 inf...

Страница 2: ...on Never attempt to perform maintenance when cleaning solution is hot Never open equipment or attempt service warranty related repairs without first contacting UltraSonic LLC for safe and proper proce...

Страница 3: ...in the tank longer than necessary This can result in erosion of the part surface and or the bottom of the tank Do not allow moisture to build up inside the unit this can cause electrical shorts and c...

Страница 4: ...up button Heater Control Ultrasonic lights will display green Operating temperature is pre set 150 F on the TEMP CONTROL Initial heat up time using cold water is approximately two hours For automatic...

Страница 5: ...UltraSonic LLC Model Ultra 6000FLT 5 Operation Instructions Control Panel...

Страница 6: ...tart Stop Agitation Timer 6 Filtration Manual Start Stop Filtration Timer 7 Auxiliary Manual Start Stop Timer 8 Up Agitation Table 9 Down Agitation Table 10 Menu Machine Timers and Settings See Progra...

Страница 7: ...ON Heat Button Manual Start Stop Heating Ultrasonic Button Manual Start Stop Ultrasonic Operation Agitation Button Manual Start Stop Agitation Operation Filtration Button Manual Start Stop filtration...

Страница 8: ...button until desired Menu To return back to a Menu selection press down button to return To select desired Menu Option press Menu Button until edit position is reached then use Up and Down Buttons to...

Страница 9: ...Button to move to next setting Day AUX Control Set In Menu Press UP Button until Day AUX Control press Menu Button until Day Time On Off use Up Down Buttons to set ON or OFF Press Menu Button to reach...

Страница 10: ...in tank is slowed Most users regularly replace their filter each month to avoid any decrease of flow Solution should be replaced regularly to avoid a drop in cleaning performance that will result from...

Страница 11: ...ed earlier for refilling and start up procedures MAXIMIZING ULTRASONIC PERFORMANCE Temperature Temperature has a dramatic effect on the cleaning performance and time needed to clean a part The recomme...

Страница 12: ...ntaminated Solution As contaminants build up in the solution the ultrasonic performance drops The cavitation bubbles waste their energy imploding on the contaminants and not on the part surface It is...

Страница 13: ...LING ULTRASONIC LLC 513 502 9746 SPECIAL NOTE PLEASE RETAIN ORIGINAL SHIPPING CRATE Our service tech will help troubleshoot any problem and instruct user on the safe and proper procedures for repairs...

Страница 14: ...n no case shall UltraSonic LLC be responsible for any incidental or consequential damages This warranty does not apply to Equipment or components subjected to misuse improper installation alteration m...

Страница 15: ...d _________ Voltage Supply to Machine with heaters on L1 to L2 ___________ L2 to L3 ___________ L1 to L3 ___________ L1 to Ground _________ L2 to Ground ________ L2 to Ground _________ I have received...