OPERATION 

OPERATION 

 

TO SET TRAVEL LIMITS: 

 

1. 

Use the DP1U controller “Up” and “Down” buttons to drive the lifter to the desired 

up limit

 position.  

2. 

Once the desired 

up limit

 travel has been reached press “S” then “1” within two seconds. This saves 

the 

up limit

 to the lift controller. Holding “1” should now drive the lift to the saved up limit. 

3. 

Use the DP1U controller “Up” and “Down” buttons to drive the lifter to the desired 

down limit

 position.  

4. 

Once the desired 

down limit

 travel has been reached press “S” then “2” within two seconds. This 

saves the down limit to the lift controller. Holding “2” should now drive the lift to the saved down limit. 

5. 

The infrared remote will now control the lift between the set limits. 

 

LEARNING A NEW REMOTE: 

To learn a new remote handset, point the remote at the IR receiver then press and hold the stop “ 

“ button 

for 10 seconds.  
 
 

 

 

 

 

DP1U 

Infrared Remote 

Ultralift UIRC 

 

 

 

 

 

 

 

IMPORTANT 

 

The lift should not be run up and down more than 4 times, or continuously at full load for 

more than 1 minute without a 10-minute break. 

 

Overheating will damage the Control Box. 

 

Содержание SPARTAN

Страница 1: ...PRODUCT MANUAL SPARTAN CEILING TILT TV LIFT...

Страница 2: ...iring into control systems RISK OF ELECTROCUTION Do not connect any power to the lift until installation is complete Attach the display panel after the lift has been properly installed and tested WEAR...

Страница 3: ...3 PRODUCT DIAGRAM SPARTAN PRODUCT DIAGRAM SIDE TRIM PANELS SCREEN HANGING RAILS CEILING CLOSURE PANEL LID CLOSURE PANEL REMOVABLE ACCESS PANEL CONTROL BOX IS ON THIS SIDE...

Страница 4: ...4 PRODUCT DIAGRAM SPARTAN A A LENGTH WIDTH B PLASTER CEILING LENGTH 3 120 DEPTH LENGTH 160 C D 10 or 13...

Страница 5: ...SPARTAN E SECTION A A 93 63 DETAIL B 12MM MOUNTING POINT 3 ULTRALIFT CEILING PANEL 12 REAR PANEL GAP DETAIL E AREA TO BE PLASTERED 3 FRONT PANEL GAP 5 SIDE PANEL GAP DETAIL C 5 SIDE PANEL GAP 12 REAR...

Страница 6: ...t in relation to dimensions loading capacity and functionality Read instructions completely before proceeding Follow instructions carefully Installation contrary to instructions invalidates warranty C...

Страница 7: ...the Audio Visual cables to the lift position in the ceiling See the Cable Management instructions to be followed post install 4 A double power point is required in the ceiling to power the Spartan and...

Страница 8: ...unit in place using the coach screws and through the mounting holes NOTE Ensure the supporting timber frames are in parallel When using this method of installation the lift s frame can be pushed out...

Страница 9: ...to the lift position in the ceiling See the Cable Management instructions to be followed post install 3 A double power point is required in the ceiling to power the Spartan and the display panel NOTE...

Страница 10: ...10 INSTALLATION METHOD 2 SPARTAN FRAME WIDTH 186MM FRAME DEPTH 126MM A A 4 x ROOF MOUNTING PLATES B SECTION A A DETAILB ALLTHREAD OPTION LOCKING NUTS ALLTHREAD DYNABOLT OPTION...

Страница 11: ...to achieve line of sight to the remote 3 Once Spartan unit is safely secured refit any removed panels in reverse order as you took it apart 4 Extend the plaster to fill the gaps up to the trim panel...

Страница 12: ...ATION SPARTAN B SIDE CUT AWAY VIEW BLUE PLASTER INFILL AREA A FRONT CUT AWAY VIEW BLUE PLASTER INFILL AREA 170 DETAILA FRONT TRIM PANEL CEILING PLASTER 25 13 STANDARD PLASTER DETAIL B SIDE TRIM PANEL...

Страница 13: ...on the cable management arm Be careful to avoid potential pinching of cables particularly around the cut out area 3 Reconnect power to the lift Please Note Cables must be securely attached to the fram...

Страница 14: ...14 CABLE MANAGEMENT SPARTAN B DETAIL B RUNNING CABLE THROUGH HOOP CABLE MUST PASS THROUGH HOOP...

Страница 15: ...onnect power to the lift 3 Remove the Mount Rails by loosening the two 5mm locking screws 4 Fit the rails to the back of the screen and bolt using the four Phillips head screws and washers as per diag...

Страница 16: ...16 MOUNTING THE TV SPARTAN A B DETAIL A DETAIL B VERTICAL RAILS LOCKED IN PLACE WITH LOCKING SCREW VERTICAL RAILS SLOT OVER HORIZONTAL RAILS...

Страница 17: ...should not need to be changed unless swapping to an integrated automation setup using contact closure Ports and their uses AC 240 V 50 60 Hz 200 W A1 A2 Parallel Controller Ports Bluetooth IR or Dry C...

Страница 18: ...ion 4 Once the desired down limit travel has been reached press S then 2 within two seconds This saves the down limit to the lift controller Holding 2 should now drive the lift to the saved down limit...

Страница 19: ...rrow to stop Press the S button and within 2 seconds press the 1 button Memory 1 is now set Repeat procedure for other Memory positions TO AUTOMATE Plug in a standard CAT category LAN cable between th...

Страница 20: ...30 0010 0010 04E2 Down 0000 0068 0000 0032 00C8 0018 0010 0030 0030 0010 0030 0010 0010 0030 0010 0030 0010 0030 0030 0010 0010 0030 0010 0030 0010 0030 0010 0030 0030 0010 0010 0030 0010 0030 0010 00...

Страница 21: ...the DP1U If using Bluetooth make sure the app is paired TV Lift Will Not Raise Past Desired Position Reset the travel limits using the DP1U Console Forced Initialisation Forced initialisation is only...

Страница 22: ...rranty covers normal domestic commercial or educational use only It does not cover damage malfunction neglect build up of dirt or dust abuse maladjustment of customer controls mains supply problems th...