Programming Process 

I. Key Information – provided as a example only – you need to determine values for each for your lift: 

Motor tube diameter 

51.1

 mm 

Motor rpm 

 

12 

turns/minute 

Show position   

1500

 mm from home/closed position (measured from bottom of the projector lift frame) 

Service position  

3000

 mm from home/closed position (measured from bottom of the projector lift frame) 

   The 

Service position (

fully lowered

) is not programmed here. It is adjusted using the limit 

switch on the tubular motor. Please refer to the “Wiring-Adjusting Motor Limits” section of 
the Prolift Product Manual. 

 

II. Calculations: 

1.

 

Motor tube circumference = 

π

 x D = 

3.14159

 x 

51.1

 = 

160.535

 mm 

2.

 

Rate of turn(sec) = rpm x result(1)/60 = 

12

 turns/min x 

160.535

 mm/turn divided by 60 sec = 

32.107 

mm/sec 

3.

 

Show position travel time (sec) = Show position/rate of turn = 

1500

 mm/

32.107

 = 

46.71

 seconds 

4.

 

Maximum travel time (sec)  = Service position/rate of turn = 

3000

/

32.107 

=  

93.43 

or 

93

 seconds 

5.

 

Show position travel time, in %, away from reference = result(3)/result(4) = 

46.71

/

93

 x 100 = 50.22 or 

50

 

 

III. Programming steps

 (see IV. Programming instructions using the 24-channel Programming IR/RF Remote Transmitter.)

1.

 

On the programming line 7 below, enter the calculation result of number 4 above, i.e. 

093

2.

 

On the programming line 8 below, enter the calculation result of number 5 above, i.e. 

50

3.

 

To fine tune viewing height, do steps 14 & 15 below.  
 

 

Command 

Description 

Stop+O7+C7>Open ALL 

(press & hold for >5 sec.)

>

Stop

 

Clears and restores all memory to factory default 

 

 

 

Stop+O7+C7>O1>C1>O

2

>Stop 

Assign the main channel to Channel 2 of remote transmitter

(see Figure 2)

 

Stop +O7+C7>O2>C2>O

1

>Stop 

Assign Show Position to Channel 1 of remote transmitter 

(see figure 2)

 

 

 

 

Stop +O7+C7>O2>C10>O2>Stop 

Enable memory A & B to Channel 1 of remote transmitter 

(see figure 2)

 

 

 

 

Stop +O7+C7>O2>C10>O11>Stop 

Change reference for travel time to bottom (or close position) limit 

Stop +O7+C7>O2>C10>O13>O

10

>O

9

>O

3

>Stop 

Set maximum travel time (001 to 299 sec). press Open

10

 for zero 

 

 

 

Stop +O7+C7>O2>C11>O

5

>O

10

>Stop 

Set travel time of memory A (open button) to 

xy

% away from reference 

Stop +O7+C7>O2>C12>O

10

>O

10

>Stop 

Set travel time of memory B (close button) to 

0

% away from reference 

 

 

 

10  Stop +O7+C7>O2>C10>O8>Stop 

Enable memory positions A & B on manual/dry contact input 

(see figure 1)

 

 

 

 

14  Stop +O7+C7>O2>C11>

O11*

>Stop 

Nudge position** of memory A 1/40

th

 second away from the reference 

15  Stop +O7+C7>O2>C11>

O12*

>Stop 

Nudge position** of memory A 1/40

th

 second towards the reference 

 

 

 

Note: *   Press Open 11 (

O11)

 or Open 12 (

O12) 

as many times as desired before pressing STOP 

 

** 1 Nudge Position (1 Green color flashing on the RP60ABMH controller LED) is approximately 1 mm drop/movement 