42
NT UF 831 CO GB (b) / March 2014
5.4.7 "Totalizers settings" menu (if activated)
1) Activation and direction of metering
For each of the totalizers, the possible modes are:
OFF
: totalizer not activated,
+
: totalization of the positive flows, in other words going from the upstream probes to the
downstream probes (see the wiring of the probes),
–
: totalization of the negative flows, in other words going from the downstream probes to the
upstream probes,
±
: totalization of all flows, whatever the direction.
2) Pulse unit and weight
Each activated totalizer emits an incrementation pulse (which can be returned on a relay output; see p.X)
each time that the Pulse weight x Unit volume flows in the metering direction of the totalizer.
The possible units are: 1ml, 1l, 1m
3
, 1000 m
3
, 1Gal, 1Bbl.
3) Resetting a totalizer
To reset a totalizer:
1.
Switch to measurement mode (long press on the
Fn
key) on the page of the totalizer concerned,
2.
Press the
A
key until the totalizer that you wish to reset is displayed on the right,
3.
Press the
B
key to reset the totalizer. A negative image of the pop-up menu is then displayed.
Содержание UF 831
Страница 5: ...5 NT UF 831 CO GB b March 2014 CHAPTER 1 OVERVIEW...
Страница 10: ...10 NT UF 831 CO GB b March 2014 CHAPTER 2 SAFETY INSTRUCTIONS...
Страница 14: ...14 NT UF 831 CO GB b March 2014 CHAPTER 3 INSTALLATION AND WIRING...
Страница 22: ...22 NT UF 831 CO GB b March 2014 CHAPTER 4 IMPLEMENTING A MEASURING POINT...
Страница 26: ...26 NT UF 831 CO GB b March 2014 CHAPTER 5 USING AND CONFIGURING THE UF 831...
Страница 59: ...59 NT UF 831 CO GB b March 2014 CHAPTER 6 FUNCTION ENGINE...
Страница 61: ...61 NT UF 831 CO GB b March 2014 CHAPTER 7 PC SOFTWARE...
Страница 77: ...77 NT UF 831 CO GB b March 2014 Appendix 1 Characteristic echo signals...
Страница 80: ...80 NT UF 831 CO GB b March 2014 Appendix 2 Speed of sound in water...