background image

    ALARM MODELS ONLY                 

NOTE- If the system has been triggered (shock sensor, door input..), the siren will sound for approximately 
60 seconds. Press and release the lock or unlock button to silence the siren (the system will remain armed). 
Press the unlock button to disarm the system. The siren and park lights will flash three times to indicate the 
system had been triggered.

SYSTEM PROGRAMMING - 

Menu 1

PAGE 26

95 SERIES

INSTALL  MANUAL

 SHOCK SENSOR SETTINGS 

PRESS AND RELEASE THE UNLOCK BUTTON TO 
DECREASE THE SENSITIVITY. THE LCD WILL SHOW 
THE CURRENT SETTING. THE LOWEST (LEAST 
SENSITIVE SETTING IS SEN 1. 

THE SHOCK SENSOR SENSITIVITY IS SET USING THE REMOTE PROGRAM MODE 
FEATURE. ALARM MODELS ONLY. 

PRESS AND RELEASE THE START BUTTON TO 
INCREASE THE SENSITIVITY. THE LCD WILL SHOW 
THE CURRENT SETTING. THE HIGHEST (MOST 
SENSITIVE) SETTING IS SEN 10.

PRESS AND RELEASE THE STATUS BUTTON ON THE REMOTE TO EXIT.

ENTER REMOTE PROGRAM MODE

ADJUSTING THE SENSOR SENSITIVITY

EXIT PROGRAM MODE

  

UL

TRA

UL

TRA

UL

TRA

SEN 3

OFF

SEN 7

SEN 5

OFF

OFF

1

1

1

UL

TRA

M-1234

PROGRAM

TO ENTER PROGRAM  MODE

 

PRESS AND HOLD THE STATUS BUTTON ON THE
REMOTE FOR 4 SECONDS.
THE REMOTE WILL BEEP 1 TIME AND THEN 3 TIMES.
THE DISPLAY WILL SHOW “PROGRAM” & “M-1234"

ENTER SHOCK SENSITIVITY PROGRAMMING

PRESS AND RELEASE THE UNLOCK BUTTON
THE SENS LEVEL WILL BE DISPLAYED

SYSTEM PROGRAMMING - 

Menu 1

PAGE 27

95 SERIES

INSTALL MANUAL

 QUICK VIEW OPERATIONS

SYSTEM PROGRAMMING - 

Menu 1

QUICK VIEW OPERATION CHART

 1 SECOND

 3 SECONDS

1 SECOND (PANIC OR ALARM) 

 1
 1

 OFF

LOCK / ARM ALARM

  ACTIVATE PANIC

ALARM/ PANIC OFF

 1 SECOND

1 SECOND (PANIC OR ALARM)

HOLD FOR 3 SECONDS

2

OFF

2 + 1

UNLOCK  / DISARM

ALARM/ PANIC OFF

1 SECOND

1 SECOND WHEN RUNNING

3 SECONDS W/ REMOTE START

1
1
2

 REMOTE START

EXTENDED RUNTIME

SHUTDOWN

HOLD FOR 3 SECONDS

2
1

TRUNK RELEASE

BUTTON

LENGTH OF PRESS

 CHIRPS / 

FLASHES

SYSTEM OPERATION

SERVICE MODE / EMERGENCY OVERRIDE

TO AVOID SERIOUS INJURY, this remote start system must be set into Service Mode 
before any under hood servicing is started. Service Mode will prevent the vehicle from 
starting while the vehicle is being serviced. It is the sole responsibility of the vehicle’s 
owner to place the system into Service Mode. The manufacture accepts no 
responsibility for accidental starting of the vehicle while the vehicle is being serviced.

ACTIVATING  / DEACTIVATING VALET MODE / EMERGENCY OVERRIDE

Turn the Ignition Key ON

(Leaving the key ON)

Press and hold the Valet switch for 8 to 15 seconds 
(Time depends on "Valet Settings" Program Option) 

 REMOTE START AND ALARM DEACTIVATED

 REMOTE START AND ALARM ACTIVATED

 5 CHIRPS = OFF

 2 CHIRPS = ON

HOLD FOR 3 SECONDS

PRESS AND RELEASE

5 LONG

STATUS

STATUS CHECK ON 2WAY

Содержание 3295Series

Страница 1: ...ultrastarters com THIS MANUAL COVERS THE OPERATIONS OF THE 3295 4295 SERIES REMOTE STARTERS AND ALARMS WARNING NEVER USE AN AUTOMATIC TRANSMISSION STARTER IN A MANUAL TRANSMISSION VEHICLE 95 SERIES Ad...

Страница 2: ...Connector Views Wiring Description PROGRAM MENUS 15 23 Program Menu 1 Detailed Program Menu 2 Detailed Program Menu 3 Detailed Program Menu 4 Detailed DOOR LOCK DIAGRAMS 24 25 Relay Diagrams SHOCK SEN...

Страница 3: ...ACH DETECTION INPUT CONNECT TO COIL INJECTOR BRAKE SWITCH INPUT 12VOLT WHEN BRAKE IS PRESSED HOOD PIN SWITCH GROUND WHEN HOOD IS OPENED PARK BRAKE INPUT M SERIES ONLY NEGATIVE DOOR INPUT WHEN DOOR OPE...

Страница 4: ...to the data port to set the default to Fortin bypass module 1 2 3 4 SELECTABLE PARK LIGHT OUTPUT GROUND OUTPUT FOR ADDITIONAL SENSOR FULL TRIGGER FOR ALARM MODELS PRE WARN TRIGGER FOR ALARM MODELS OUT...

Страница 5: ...S USING THE DATA TO DATA TYPE CONNECTION THERE ARE 2 SELECTION TYPES THE DEFAULT SETTING IS FOR IDATALINK MODULES THE SECOND IS FOR FORTIN BYPASS MODULES IF THE BYPASS KIT IS A IDATA PRODUCT SIMPLY CO...

Страница 6: ...AMMING 1 Cycle the Ignition Key On Off On Off On Leaving the key ON 2 Press and HOLD the Program Switch The Horn Siren will chirp 1 time CONTINUE to HOLD If the Horn Siren does not chirp turn the key...

Страница 7: ...PUT UNLOCK STATUS WITH DISARM PASSIVE DOOR LOCKS PASSIVE DOOR LOCKS DISABLED PASSIVE DOOR LOCKS ENABLED 8 PASSIVE ARMING PASSIVE ST KILL FULL PASSIVE ARMING ENABLED PASSIVE SAFETY REARM ENABLED 9 ALAR...

Страница 8: ...MODE 3 PROGRAM MODE 4 PROGRAM MODE 3 see page 21 for detailed instructions PROGRAM MODE 4 see page 23 for detailed instructions SYSTEM PROGRAMMING Menu 1 SYSTEM PROGRAMMING Menu 1 AUTO TACH TACHLESS...

Страница 9: ...proper Tach signal has been programmed the system will chirp the Horn Siren and flash the park lights two times If the tach wire is not connected the park lights will flash and the horn will chirp 4 t...

Страница 10: ...WIRING DETAILS WHITE SYSTEM GROUND INPUT JUMPER SELECTABLE PARK LIGHT OUTPUT OR SIREN HORN OUTPUT STARTER KILL ANTI GRIND OUTPUT BLACK ORANGE BROWN BLUE OUTPUT TO ACTIVATE IGNITION CIRCUIT WHITE SELEC...

Страница 11: ...arm Models This output can be programmed to act as an additional HORN output PIN 2 ORANGE Starter Kill Anti Grind This wire can be connected to an additional relay to disable the start circuit when th...

Страница 12: ...UTPUT FOR TRUNK RELEASEACTIVATION NEGATIVEACCESSORYOUTPUT AUXILIARYOUTPUT 2 AUXILIARYOUTPUT 1 PROGRAMMABLE OUTPUT BRAKE SWITCH INPUT WHEN BRAKE IS PRESSED HOOD PIN SWITCH INPUT TACH WIRE INPUT WAIT TO...

Страница 13: ...switch that changes to 12volts when the brake is pressed Connect to door pin for Passive Arming on the 3295 8 BLACK WHT N A 9 GREEN WHT Hood Pin Input Connect this wire to the supplied hood pin switc...

Страница 14: ...nect this wire to the your bypass modules negative turn on wire When the remote starter is activated this wire will switch to ground 2 BLACK Wire System Ground Connect this wire to the ground input on...

Страница 15: ...TER PROGRAMMING 1 Cycle the Ignition Key On Off On Off On Leaving the key ON 2 Press and HOLD the Program Switch The HORN SIREN will chirp 1 time CONTINUE to HOLD If the HORN SIREN does not chirp turn...

Страница 16: ...em will provide 2 unlock pulses w unlock and 1 lock pulse w lock 1 CHIRP SETS OPTION 2 DOUBLE LOCK SINGLE UNLOCK PULSE The system will provide 2 lock pulses and 2 unlock pulses CHANGE SETTING 2 GOTO S...

Страница 17: ...TING 5 IS SELECTED 5 CHIRP PRESS 1 TIME 5X 1 CHIRP 2 CHIRP 3 CHIRP CHANGE SETTING 6 GOTO SETTING 7 PRESS RELEASE THE VALET SWITCH PRESS HOLD THE VALET SWITCH UNTIL THE SIREN CHIRP S SETTING 6 AUXILIAR...

Страница 18: ...SETS OPTION 3 PASSIVE ARMING DISABLED The alarm will not automatically Must be armed by the remote DEFAULT SETS OPTION 1 INTERNAL DISABLED The Internal Sensor input will be Active not be monitored wh...

Страница 19: ...CON T ON NEXT PAGE SETS OPTION 1 30 SECOND The park light output will flash for all functions and will stay active for 30 seconds when unlock is pressed SETS OPTION 2 NORMAL OPERATION The park lights...

Страница 20: ...HIRP SETS OPTION 1 TYPE 2 The doors will unlock before remote start lock when remote starter starts and again when the remote start shuts down SETS OPTION 2 RE LOCK The doors will automatically lock w...

Страница 21: ...PRESS HOLD THE VALET SWITCH UNTIL THE SIREN CHIRP S SETTING 4 RE ARM OPTIONS THE SIREN WILL CHIRP 4 TIMES WHEN SETTING 4 IS SELECTED 4 CHIRP PRESS 1 TIME 4X 1 CHIRP 2 CHIRP 3 CHIRP SETS OPTION 1 TYPE...

Страница 22: ...LD THE VALET SWITCH UNTIL THE SIREN CHIRP S SETTING 7 LED FLASHES THE SIREN WILL CHIRP 7 TIMES WHEN SETTING 7 IS SELECTED 7 CHIRP PRESS 1 TIME 7X 1 CHIRP 2 CHIRP SYSTEM PROGRAMMING Menu 1 ENTERING PRO...

Страница 23: ...OTO SETTING 5 PRESS RELEASE THE VALET SWITCH PRESS HOLD THE VALET SWITCH UNTIL THE SIREN CHIRP S SETTING 4 TACH WAIT THE SIREN WILL CHIRP 4 TIMES WHEN SETTING 4 IS SELECTED 4 CHIRP PRESS 1 TIME 4X 1 C...

Страница 24: ...ay Blue NEGATIVE DOOR LOCK LOW CURRENT Ground Ground 12volts 12volts 87 86 85 87a 30 87 86 85 87a 30 Alarm and or Starter Module Door lock Output Blue Green Vehicle s Lock Unlock Switch USE SPDT 12v R...

Страница 25: ...witch USE SPDT 12v Relay REVERSE POLARITY DOOR LOCK SYSTEM 12volts 12volts Alarm and or Starter Module Door lock Output Blue Green 87 86 85 87a 30 87 86 85 87a 30 x x x x USE SPDT 12v Relay AFTER MARK...

Страница 26: ...LEAST SENSITIVE SETTING IS SEN 1 THE SHOCK SENSOR SENSITIVITY IS SET USING THE REMOTE PROGRAM MODE FEATURE ALARM MODELS ONLY PRESS AND RELEASE THE START BUTTON TO INCREASE THE SENSITIVITY THE LCD WIL...

Страница 27: ...INJURY this remote start system must be set into Service Mode before any under hood servicing is started Service Mode will prevent the vehicle from starting while the vehicle is being serviced It is...

Страница 28: ...TION KEY ON OFF ON OFF ON LEAVE THE KEY ON ENTERING TRANSMITTER PROGRAM MODE PRESS AND HOLD THE PROGRAM SWITCH THE PARK LIGHTS WILL TURN ON AND THE HORN WILL CHIRP 1 TIME CONTINUE TO HOLD THE PROGRAM...

Страница 29: ...ISSUE ULTRA FAULT 1 ULTRA BRAKE 1 TOGGLE HOOD FAULT THIS FAULT WOULD OCCUR IF THE HOOD WAS OPENED OR THE HOOD SWITCH IS BROKE OR OUT OF ALIGNMENT ULTRA FAULT 1 ULTRA HOOD 1 TOGGLE TACH FAULT THIS FAUL...

Страница 30: ...D THE TRIGGER ULTRA ALARM 1 ULTRA DOOR 1 ULTRA ALARM 1 ULTRA SHOCK 1 ULTRA ALARM 1 ULTRA HOOD 1 ULTRA ALARM 1 ULTRA AUX 1 ULTRA ALARM 1 ULTRA PANIC 1 TOGGLE TOGGLE TOGGLE TOGGLE TOGGLE SHOCK TRIGGER T...

Страница 31: ...and the HORN optional will honk the same number of times as the events in memory Maximum four events four honks NOTE If the HORN does not honk there are no events in memory Step 3 Press the Program B...

Страница 32: ...horized dealer but have been registered please fill out the service request form at http www ultrastarters com wiring_diagrams html PRODUCT INFORMATION www ultrastarters com TECHNICAL SUPPORT support...

Отзывы: