Replacing Consumable Parts
It is expected that the user be capable of changing out the following consumable parts.
Hepa Pre-filter
1. Replace with new filters monthly
Hepa Filter
1. Disconnect power cable from filter unit to the top of the machine
2. Remove filter unit from machine
3. Remove 4 self-tapping screws holding filter onto filter unit
4. Place sealing foam around top edge of new HEPA filter
5. Place filter unit on top of new HEPA filter
6. Screw in self-tapping screws through filter unit into new HEPA filter
7. Place filter unit into machine
8. Connect power cord to top of machine
Light Module
1. Remove light side panel from machine
2. Open cure station door
3. Remove mounting screws from light module
4. Pull out old light module by the handle
5. Insert new light module
6. Insert mounting screws into new light module
7. Close cure station door
8. Attach light side panel to machine
Spindle Suction Cups
1. Put machine into manual mode
2. Enter manual control screen
3. Index spindles until the one you want to change is over the drying station
4. Open water side door
5. Hold clocking trip dog at top of spindle and unscrew bad suction cup
6. Screw on new suction cup
7. Tighten disc and coupler
8. Close water side door
9. Index spindles until the next suction cup to be changed is over the drying station
10. Repeat steps 4 through 8 until all suction cups are changed
Robot Suction Cups
1. Put machine into manual mode
2.
Enter “robot controls” screen
3.
Press “Rbt. Motor” button to turn on motor
4.
Press “cup change” button
5. Open water side door
6. Unscrew bad suction cup from robot actuator
7. Screw new suction cup onto robot actuator