Heritage II Digital Turn

Quick Reference Guide: 

Please refer to the product User Manual for full instructions for use.

Alternating Mode

Control Panel Lock Out

To unlock panel:

Press & hold for 3 seconds to unlock control panel.

To lock panel:

To lock out the control panel press the 

Lock Out

button and all functions will be locked.

If the control panel is not used for a period of 30

seconds it will automatically lock out and inhibit

the use of the functions.

Alternating

 mode is the default mode for the

V\VWHP:LWKLQWKLVPRGHWKHPDWWUHVVZLOOLQÀDWH

DQGGHÀDWHLQDQDOWHUQDWLQJLQFHOOF\FOH

The alternating cycle will continue at the selected

cycle time until another mode is selected.

Static Mode

Pressing the 

Mode

 button until the 

Static

 indicator

illuminates puts the system into 

Static

 mode.

The system will automatically return to

Alternating mode 

after 20 minutes.

Alternating Cycle Time Selection

&KRLFHRIPLQXWHV

To select press 

Cycle

 button until required cycle

time is displayed in LCD screen.

Auto Firm Mode

Pressing the 

Auto Firm

EXWWRQ

will inflate cells 

to the 

Max Weight Banding

 in order to create a 

firm surface

The system will automatically return to

Last Mode

 

Of Operation 

after

 20 minutes.

Comfort Control 

The

 Soft 

and

Firm

 buttons allow adjustment of 

SUHVVXUHVZLWKLQDVDIHSUHVHWUDQJH

When pressing the 

Firm

 button, the output pressure

will increase to provide a higher pressure output

and thus increased support.

When pressing the Soft button, the output

pressure will be decreased to provide a lower

pressure output and thus increased comfort.

&RQVWDQW/RZ3UHVVXUH&/3

 Mode

Pressing the 

Mode

 button until the CLP indicator

illuminates puts the system into 

Constant Low

Pressure 

mode.

:LWKLQWKLVPRGHWKHFHOOVDUHQRWDOWHUQDWLQJDQG

WKHLQWHUQDOFHOOSUHVVXUHZLWKLQWKHPDWWUHVVLVVHW

DWPPKJWRSURYLGHDFRPIRUWDEOHSUHVVXUH

UHGXFLQJVXUIDFH

Simultaneously pressing the 

Soft

 and 

Firm

 buttons on the

control panel will manually activate 

Auto-Detection

.

2QFHDFWLYDWHGWKHLQGLFDWRUOLJKWZLOOIODVKDQGWKHV\VWHP

will start detecting the patients weight

GLVWULEXWLRQ

 to set

internal pressures

appropriately.

 The system will

continuously check this every 2 hours.

Auto-Detection - 

detecting patient weight (distribution)

30

130

255

50 75 100

165 205

kg

CLP

Alarms

 Mute 

The 

Alarm Mute

 button temporarily resets

 

the 

audible 

Low Pressure

/

Power Failure

/

Service 

alarms. Should the situation not be resolved and 

the fault condition continues the alarm will resume. 

Please refer to the manual

 for other alarms

Mode

Function Mode button

Pressing the 

Mode

 button allows you to cycle

between

 

the different modes available such as

Alternating

Static

DQG

Constant Low Pressure

A Full 

R

isk 

A

ssessment should be completed before using this System

 

-

Please refer to User Manual for guidance

www.ultimatehealthcare.co.uk  |  Tel: 0333 321 8996

In the event of a patient suffering a cardiac 

arrest and CPR needing to be administered:

for 

up to 12 to 24 

hours.

CPR Valve

 - 

Transport Mode - 

Disconnect air pipe connector and 

immediately 

place the

 

cover over it.

Restore the mattress by reconnecting the

 

supply tubes to the power unit.

To activate the CPR: 

P

ull and rotate the dial of 

the CPR valve to ‘click’

 into the OPEN position. 

At the same time, disconnect the air pipe connector 

from the Pump to speed up the air release.

l

eft hand side of the mattress

To reset CPR: 

Ensure the dial of the CPR 

attachment is rotated until it ‘clicks’ into the 

CLOSED position.