13
DISASSEMBLING
1. Remove the glass plate.
2. Place the 2 mm hex wrench on the screw in the front left corner of the build plate. Fig. 23.
Hold the corresponding build plate screw at the bottom of the build plate with your hand.
3. Turn the build plate screw with the hex wrench to loosen the parts completely.
The parts may fall down.
4. Remove the build plate clamp.
ASSEMBLING
1. Place the new build plate clamp between the spring and the build plate. Fig. 24.
2. Place the build plate screw with the washer around it against the bottom of the build plate and hold it there.
3. Insert the screw from the top and use the hex wrench to tighten it. Fig. 25.
Tighten the screw until there is quite some tension on the spring, so that the vibrations of the build plate
are reduced. But make sure there is at least 2 mm distance between the screw terminal of the heated bed
and the base plate.
Repeat these steps for the build plate clamp at the front right of the build plate.
4. Place the glass plate back on the build plate and close the build plate clamps.
BUILD PLATE
CLAMPS
23
25
24