background image

CX8936 

C

OMMISSIONING AND OPERATION

 

 

12 

5

 

Commissioning and operation 

 

5.1

 

Connecting locking units 

To connect a locking unit with the online module, you have to perform the follow-
ing steps: 

 

Bring the locking unit which you want to connect into the service mode by 
holding the service key in front of the locking unit. 

 

 

Use a screwdriver or a similar tool to turn the rotary switch (6) so that the 
arrowhead points to Position 8. Then briefly press the button (7) to switch to 
the pairing mode and teach in the locking unit within reach. 
 

 

6) Rotary switch 
7) Button 
8) LEDs 

 

If successful, the green LED lights up several times and the lock leaves the service 
mode directly. If not successful, the red LED lights up several times and the lock 
remains in the service mode. 
The yellow LED flashes additionally to confirm the button input. The blue LED 
flashes to signal the BLE activity. 
 

 

Turn the rotary switch back to the home position.  

 

Rotary switch position 

Function 

Home position 
For Wiegand: Sends a test sequence via Pins 4 and 5 
when the button (7) is pressed. 

Briefly press the button (7) to set the online module into 
the service mode. 

Briefly press the button (7) to perform the pairing of the 
online module with the locking unit that is in reach and 
in service mode or to delete an existing paired locking 
unit. 

Briefly press the button (7) to delete all the saved locking 
units and parameters. 

Any 

If you keep the button (7) pressed longer than 4 s and 
then release it, the online module switches to the service 
mode (as at Position 4). 

Содержание CX8936

Страница 1: ...CX8936 Online module with Bluetooth Low Energy Operating and installation instructions...

Страница 2: ...r GmbH Gutenbergstra e 2 4 97297 Waldb ttelbrunn Germany Tel 49 931 40672 0 Email contact UundZ de www UundZ de These operating and installation instructions are protected by copyright The in formatio...

Страница 3: ...Installation 10 4 1 General installation information 10 4 2 Installation 10 4 3 Pin assignment 11 5 Commissioning and operation 12 5 1 Connecting locking units 12 5 2 Configuring the online module 13...

Страница 4: ...on Uhlmann Zacher GmbH accepts no liability for malfunctions such as impossi ble access to injured persons operational malfunctions damage to property or other damage resulting from non observance of...

Страница 5: ...the product must not be operated any longer Modifications or additions to the product are not permitted Usage outside the stated specifications is not permitted 2 3 General safety information Observe...

Страница 6: ...on the device version No external antenna is required for the connection 3 2 Layout and scope of delivery Layout using the example of the grey housing version Other housing versions similar 1 Housing...

Страница 7: ...in white 3 4 Technical data 3 4 1 General technical data Designation Value Number of cou pleable locking units depending on versions For data transfer via RS485 8 For Wiegand clock data 1 Frequency ra...

Страница 8: ...CX8936 PRODUCT DESCRIPTION 7 3 5 Dimensions Grey housing...

Страница 9: ...CX8936 PRODUCT DESCRIPTION 8 White oval housing...

Страница 10: ...CX8936 PRODUCT DESCRIPTION 9 White rectangular housing...

Страница 11: ...is smooth dry and firm enough Do not place the units close to each other to avoid radio interfer ences Mark the fastening points through the bottom of the housing No 9 in layout diagram If required dr...

Страница 12: ...th pin 6 7 8 insulated against ground connection not used 4 Wiegand 0 5 Wiegand 1 6 7 8 Input potential 5 24 V not used 9 power supply 5 24 VDC can be used alternatively to 1 10 power supply ground ca...

Страница 13: ...If not successful the red LED lights up several times and the lock remains in the service mode The yellow LED flashes additionally to confirm the button input The blue LED flashes to signal the BLE ac...

Страница 14: ...and test the connection via the Clex public UZ Reader protocol The parameters for the Wiegand connection can also be set with this tool Con tact your Integration partner to purchase the software The C...

Страница 15: ...its Blue constant lighting up All paired locking units are connected Blue rapid flashing Device tries to wake up a locking unit in the wake on radio mode WOR Yellow Button input Red Active online conn...

Страница 16: ...6 2 Cleaning Clean the housing with a soft lint free and only slightly moistened cloth When cleaning do not use corrosive liquids or liquids that decompose plastic such as benzine turpentine etc Shar...

Страница 17: ...sal 7 1 Disassembly 7 2 Disposal Do not dispose of the device with household waste but at a municipal col lection point for special electrical waste in accordance with European Di rective 2002 96 EC D...

Страница 18: ...g BLE Bluetooth Low Energy VDE German Verband der Elektrotechnik Registered Asso ciation of the Electrical Electronic and Information Technology phg_crypt Standard protocol of the company phg Peter He...

Отзывы: