Страница 2: ...IZMIR UMD 1850 GB D IZMIR UMD 1850 GB D S DF IZMIR UMD 1850 GB D S DF VS IZMIR UMD 1850 GB S DF VS IZMIR UMD 2100 D DF IZMIR UMD 2100 D DF VS IZMIR UMD 2100 D IZMIR UMD 2100 D S DF IZMIR UMD 2100 D S DF VS IZMIR UMD 2100 S DF VS IZMIR UMD 2500 D DF IZMIR UMD 2500 D DF VS IZMIR UMD 2500 D IZMIR UMD 2500 D S DF IZMIR UMD 2500 D S DF VS IZMIR UMD 2500 S DF VS IZMIR ...

Страница 3: ...MENT OF ADJUSTABLE STAYS 11 3 3 2 MULTIPLE DEVICE USE LAY OUT POSITIONS 11 3 3 2 1 STAND ALONE USE 11 3 3 2 2 SINGLE LINE ARRAY 11 3 3 2 3 SUCCESSIVE ARRAY 11 3 3 2 4 HEAD FRIDGE AND ISLAND ARRAY 12 3 4 ELECTRICAL CONNECTIONS 12 4 DEVICE USAGE 13 4 1 THERMOSTAT ADJUSTMENTS EWPLUS 978 13 4 1 1 GENERAL INFORMATION AND INSTRUCTIONS 13 4 1 2 SET TEMPERATURE 15 4 1 3 AUTOMATIC DEFROST 15 4 1 4 MANUAL D...

Страница 4: ...DEFROST 18 4 5 THERMOSTAT ADJUSTMENTS ERC 112D 19 4 5 1 GENERAL INFORMATION AND INSTRUCTIONS 19 4 5 2 GENERAL INFORMATION AND INSTRUCTIONS 19 4 5 3 MANUAL DEFROST 19 5 SPECIAL INSTRUCTIONS FOR USE 20 5 1 DEFROSTING 20 5 2 GLASS CLEANING 20 5 3 GLASS CLEANING 21 5 4 LOADING CAPACITY 21 6 TURNING OFF AND CARRYING THE DEVICE 22 6 1 TURNING OFF THE DEVICE 22 6 2 CARRYING THE DEVICE 22 7 TURNING OFF AN...

Страница 5: ... you may need to make later 1 BASIC INFORMATION 1 1 SYMBOLS Some significant points in using the device are made attention grabbing with symbols The meaning of these symbols are stated below in accordance with their prioritization order Please pay attention to these symbols WARNING It involves information provided in order to prevent serious damages that may result in injuries loss of life and pro...

Страница 6: ... stated below The procedures performed in breach of the rules make your equipment out of warranty The assembly and demonstration of the equipment must be carried out by the Authorized Service The equipment has freezer meat and cooler modes Do not use the equipment for purposes other than its intended use Use the equipment as specified in this manual Chapter 2 3 Comply with the warning and safety i...

Страница 7: ...he user Depending on the final decision to be given by the consumer in case of experiencing any problem due to the location of the equipment all responsibility shall be borne by the consumer and the equipment shall be considered out of warranty due to problems that may emerge due to such positioning SUGGESTION In order for the equipment to be used in the most efficient way the ambient temperature ...

Страница 8: ...uch as fire sparkle etc that may lead to in flammation at the environment where the equipment is located keep your equipment away from such sources Otherwise fire explosion etc may be experienced Plug out the equipment and ventilate the environment where the equipment is located Please contact the Authorized Service The refrigerant gasses in this equipment slightly increase the sound of operation ...

Страница 9: ...equipment may be damaged and it may go out of warranty Chapter 3 If the equipment is used in accordance with the climatic conditions for which it is designed it will provide the best performance This equipment is designed to be used in indoor environments According to EN 23953 2 it must be used in environments to provide Climate Class 3 25 C 60 R H 2 4 WASTE DISPOSAL This equipment is compatible w...

Страница 10: ... close to the device Device shall be placed at least 1 meter away from heat sources oven cooker stove radiator etc Device shall be placed where there is no direct sunlight Device shall be placed away from places where there is air stream against the air condition openings under fans at doorsteps or close to windows etc SUGGESTION Comply with the Authorized Persons guidance and suggestions for plac...

Страница 11: ...carry out the balancing operation 3 3 2 MULTIPLE DEVICE USE LAY OUT POSITIONS 3 3 2 1 STAND ALONE USE Pay attention that there is at least 150 mm distance between the wall and the device back part The device may have a contact with the wall on the side A visual regarding the device s lay out is presented on Image D D 3 3 2 2 SINGLE LINE ARRAY Pay attention that there is at least 150 mm distance be...

Страница 12: ...ot cover 3 4 ELECTRICAL CONNECTIONS This device works with 220 240V 50 60 Hz 110 127 60 Hz alternating current Check this value from the label at the back of the device Image J J The aspects you shall pay attention to while using the device are stated below The plug shall be easily accessed also after the device is placed Signified voltage shall be equivalent to grid voltage Extension cables or mu...

Страница 13: ...frost Press and release increases the sliding values between Menu options or enables transition When you press it at least for 5 seconds Manuel Defrost Loop starts 2 Light internal menu status decreases the sliding values between menu options or enables transition When you press it at least for 5 seconds the light turns on off 3 Esc Press and release enables to return to the previous menu level an...

Страница 14: ...from DI Off Otherwise Aux LED Permanently on Aux output active Flashing Deep cooling Cycle active Off Aux output not active Alarms LED Permanently on alarm active Flashing alarm acknowledged Off otherwise C LED Permanently on C setting dro 0 Off otherwise F LED Permanently on F setting dro 1 Off otherwise Digital thermostats contain many parameters within themselves Your thermostat has factory set...

Страница 15: ...below Example In case the mode you want to choose is Meat mode then when you press key when AP2 is written on the screen then you switch to Meat mode NOTE In case you think that there is a problem with regards to the operation of the device or with regards to digital thermostat settings please ask for support from the Authorized Person 4 1 2 SET TEMPERATURE To display the Setpoint value press the ...

Страница 16: ...GENERAL INFORMATION AND INSTRUCTIONS Thermostat visual is presented on Image H1 H1 Keys 1 Press and release increases the sliding options among menu options and enables transition 2 Light Internal menu status reduces sliding values among menu options or enables transition When you press for 5 seconds the Light turns on off 3 Esc Press and release return to the previous menu and approval of paramet...

Страница 17: ...le active Off Aux output not active F LED Permanently on F setting dro 1 Off otherwise C LED Permanently on C setting dro 0 Off otherwise NOTE Your thermostat is set on factory defaults and does not requires any adjustment Only freezer without defrost mode is available for EWPlus 971 thermostat 4 2 2 SET TEMPERATURE To display the Setpoint value press the key when the SEt label is displayed The Se...

Страница 18: ...ing stack Push the uppermost or lowermost button to scan the rolling stack 4 4 THERMOSTAT ADJUSTMENTS 4 4 1 GENERAL INFORMATION AND INSTRUCTIONS The explanations regarding the sybols on the thermostat and general informtion about the settings are given below Thermostat visual is presented on Image H4 H4 1 Parameter Key 2 Up Key 3 Down Key 4 Status LED Defrosting 5 Status LED Cooling 6 Status LED F...

Страница 19: ...ls on the thermostat and general information about the settings are given be low Thermostat visual is presented on Image H3 H3 1 Defrost Key 2 Stand by Key 3 Up Key 4 Down Key 4 5 2 GENERAL INFORMATION AND INSTRUCTIONS Push the until thetemperature value is shown or push the until the temperature value is shown 4 5 3 MANUAL DEFROST Manuel start or stop of a defrost Push the ...

Страница 20: ...e supplied with the device without damaging the walls In case frosting is too much place the products inside the device in an appropriate place where they will not be ruined Then plug out the device Normally the frosting shall be melted within two 2 hours After the melting process wipe the internal wall of the device with a dry cloth and pay attention that it does not stay wet Operate your device ...

Страница 21: ...m defrosting operation Chapter 5 1 Leaving the cover of the equipment may cause frost deposit inside the equipment In order to prevent frost deposit whenyoudocontinuousloading perform manual defrosting operation on your equipment after the loading Chapter 5 1 5 4 LOADING CAPACITY Make sure that the foods loaded in the equipment are below the loading line Image I I Do not place products in the equi...

Страница 22: ...ver the equipment with materials such as plastic coatings etc NOTE If the plastic parts inside the equipment do not let the air in it may lead to odour mould growth due to humidity and perspiration Perspiration may lead to corrosion on the metal parts 6 2 CARRYING THE DEVICE Empty the foods out of the device dry the interior part of the device properly and leave the lid open Turn off the device Ch...

Страница 23: ... plug out the device Contact with the Authorized Person for the replacement of the cable of the device Appeal for help of qualified electrical expert for the socket control Compressor is always working The lids of the device is frequently opening and closing or the lid of the device is left open Do not open and close the lid of the device unless necessary and keep the lid of the device closed Devi...

Страница 24: ...be placed inside the device shall be used in accordance with Freezer Meat Cooler modes There is a problem in packaging of the product inside the device Do not place the products whose packages are damaged inside the device Water is leaking on the engine part There is damage the evaporation cup Call the Authorized People and ensure that the damaged evaporation cup is replaced There may be a crack o...

Страница 25: ...working These sounds may be normal Check the table below Device Operating Sounds Humming sound Cooler system is working Babbling rustling sounds Cooling gas is passing through pipes Clicking Compressor is being activated and deactivated Clicking when the device is turned on Interior lighting switch is on ...

Страница 26: ...26 1 2 3 4 5 6 7 8 A A B B C C ...

Страница 27: ...27 150 mm 150 mm D D E E F F G G ...

Страница 28: ...28 2 1 3 9 1 3 4 2 2 1 3 H3 H3 H1 H1 H2 H2 H4 H4 4 1 2 4 5 7 8 3 6 ...

Страница 29: ...29 I I J J 200 250 ml K K ...

Страница 30: ...30 L L ...

Страница 31: ...User Manuall General Store Type Freezers and Fridges 31 EN NOTES ...

Страница 32: ...olu Caddesi No 127 C Nazilli AYDIN TÜRKİYE T 0 256 316 10 00 F 0 256 316 10 31 ugur ugur com tr Marmara Region Headquarters Mahmutbey Mahallesi 2534 Sokak No 9A Bağcılar İSTANBUL TÜRKİYE T 0 212 624 32 28 F 0 212 541 96 36 istanbul ugur com tr www ugur com UĞUR GROUP COMPANIES RoHS A1304000400 ...