S9600-64X  Hardware Installation Guide | 7 

4

 

Identifying Your System 

S9600-64X 

 Overview 

Figure 4. 

PSU Overview 

Power supply unit (PSU) with 1+1 Redundancy. Hot swappable, field replaceable unit (FRU). 

AC Version: 

Figure 5. 

Содержание S9600-64X

Страница 1: ...S9600 64X Open Aggregation Router Hardware Installation Guide R1 0...

Страница 2: ...DC Version PSU Overview 7 Fan Overview 8 Port Overview 9 5 Rack Mounting 10 6 Installing Fan Modules 13 7 Installing Power Supply Units 14 8 Grounding the Router 16 9 Connecting Power 18 DC Version 18...

Страница 3: ...Installation Guide ii Connecting the 10MHz Interface 27 Connecting the Transceiver 27 13 Cautions and Regulatory Compliance Statements 29 Cautions and Regulatory Compliances 29 13 2 Installation Loca...

Страница 4: ...a 5G mobile Ethernet network Due to its versatility the S9600 64X can be positioned in different parts of the network to perform aggregation such as in the backhaul to aggregate BBU pooling or even a...

Страница 5: ...or grounding Crimping tool Wire stripping tool All illustrations within this document are for reference purposes only Actual objects may differ PC with terminal emulation software Refer to the Initial...

Страница 6: ...ircuit Space Clearance The S9600 64X width is 17 16 inches 43 6cm and shipped with a rack mount brackets suitable for 19 inch 48 3cm wide racks The depth of the S9600 64X chassis is 30 inches 762cm wi...

Страница 7: ...5 8 8cm in height 19 48 3cm in width and minimum reserve depth of 36 inches 91 4cm Thermal requirement S9600 64X working temperature is 0 to 45 C 32 F to 113 F airflow direction is front to back Insta...

Страница 8: ...1 pcs 0 14lbs 63 6g 1 pcs 2 Screw Kit for Grounding Lug 2 x Screws M4 L8 0mm 4 x M4 Lock Washers 2 sets DC Only 0 01lbs 2 6g 1 set 3 Micro USB Cable 3 28 1m 1 pcs 0 05lbs 24 4g 1 pcs 4 RJ45 to DB9 Fem...

Страница 9: ...DC PSU 2 2lbs 1 0kg AC PSU 2 6lbs 1 2kg Fan module 1 1lbs 498g Ground lug 0 146lbs 66 2g Adjustable rail slide 7lbs 3 2kg Micro USB cable 0 05lbs 24 4g RJ45 to DB9 female cable 0 27lbs 123 9g AC powe...

Страница 10: ...64X Hardware Installation Guide 7 4 Identifying Your System S9600 64X Overview Figure 4 PSU Overview Power supply unit PSU with 1 1 Redundancy Hot swappable field replaceable unit FRU AC Version Figu...

Страница 11: ...S9600 64X Hardware Installation Guide 8 Figure 6 Fan Overview 3 1 Redundant hot swappable field replaceable unit FRU Figure 7 DC Version...

Страница 12: ...600 64X Hardware Installation Guide 9 Port Overview Port ID Form Factor Maximum Support Distance Support Speed 0 63 QSFP28 Up to 6 2mi 10km 40GE 100GE 00 03 SFP28 Up to 6 2mi 10km 1GE 10GE 25GE Figure...

Страница 13: ...ail from the outer rail The white tab is located on the inner rail 1 3 Once the inner rail is separated push the tab located on the outer rail to unlock and slide the middle rail back Figure 9 2 Insta...

Страница 14: ...e heard when the bracket is secured onto the rack Figure 11 4 Insert the Chassis to complete the installation 4 1 Pull the middle rail fully extended into lock position an audible click can be heard w...

Страница 15: ...S9600 64X Hardware Installation Guide 12 Figure 12...

Страница 16: ...n module Then press and hold the release tab to unlock the fan module Figure 13 2 While holding down the release tab grip the fan handle and gently pull the fan module out of the fan bay Figure 14 3 A...

Страница 17: ...ps for installation The PSUs comes pre installed and the following are instructions on how to install a new PSU Safety Notices Caution Shock hazard TO DISCONNECT POWER REMOVE ALL POWER CORDS FROM UNIT...

Страница 18: ...Carefully slide the new PSU into the power bay and gently push until it is flush with the case 5 An audible click will be heard when the PSU is installed correctly The PSU will not go in all the way...

Страница 19: ...onto the case This equipment must be grounded Do not defeat the ground conductor or operate the equipment without correctly grounding the equipment If there is any uncertainty about the integrity of...

Страница 20: ...or securing the grounding lug which is located on the rear of the router and remove the protective label Figure 20 6 Using 2 M4 screws and 4 washers provided with the package contents firmly lock the...

Страница 21: ...before connecting to the PSU The following instructions are for connecting the DC Power Cable to the lug 2 1 Strip the insulation from a DC Power Cable leaving 0 5 0 02 12 7mm 0 5mm of exposed cable...

Страница 22: ...with insulation material as below Figure 24 3 Attach the power cable Locate the DC power screw type terminal block located on the PSU Remove the plastic cover that is protecting the terminal block by...

Страница 23: ...with a 48V DC power source The PSU has a built in 60A fast acting fuse based on the PSU maximum capacity which will act as a second tier system protection in case the power distribution unit s fuse is...

Страница 24: ...based on the PSU maximum capacity which will act as a second tier system protection in case the power distribution unit s fuse is not functioning 4 Verify that the power supply is operating If connec...

Страница 25: ...eference GNSS 1PPS PTP etc Solid Amber System timing clock synchronization is in free run or holdover mode SYS Off No power or in shutdown mode Solid Green Host CPU BMC boot complete Solid Amber Power...

Страница 26: ...present Only 5VSB on Blinking Red 1 sec Input power cord unplugged or input power lost with a second power supply in parallel still with AC input power Blinking between Green and Red Power supply war...

Страница 27: ...The console can be connected either with the IOIO port or the USB port If connecting with USB drivers will need to be installed To connect the console using the IOIO port locate the port labelled IOI...

Страница 28: ...1 Flow control None 4 Login to the device After the connection is established a prompt for the username and password displays Enter the username and password to access the CLI The username and passwo...

Страница 29: ...S Interface Connect an external GNSS antenna with an impedance of 50 ohms to the port marked GNSS ANT located on the front panel of the router Figure 31 Connecting the 1PPS Interface Connect an extern...

Страница 30: ...maging the optic fibers it is not recommended to use tie wraps with optical cables Read the following guidelines before connecting the transceiver Before installing the router take into consideration...

Страница 31: ...abling be done by a professional who is grounded such as by wearing an ESD wrist strap The following the steps below for connecting a transceiver 1 Remove the new transceiver from its protective packa...

Страница 32: ...eil Assurez vous que ces connexions sont facilement accessibles Caution Before mounting the device ensure that the rack can support it without compromising stability Otherwise personal injury and or e...

Страница 33: ...n radiate radio frequency energy and if not installed in accordance with the operator s manual may cause harmful interference to radio communications Operation of this equipment in a residential area...

Страница 34: ...Installation Location Statement It is recommended that the device be installed only in a server room or computer room where access is Restricted to qualified service personnel or users familiar with r...