Hardware Installation Guide
S9110-32X
100G Data Center Switch
R1.1
Страница 1: ...Hardware Installation Guide S9110 32X 100G Data Center Switch R1 1...
Страница 2: ...erview 9 Fan Overview 10 Port Overview 10 5 Rack Mounting 11 6 Installing Fan Modules 12 7 Installing Power Supply Units 13 8 Grounding the Router 15 9 Connecting Power 17 DC Version 17 AC Version 18...
Страница 3: ...ed and managed in a structured way utilizing high efficiency Ethernet connectivity With advanced capabilities these switches deliver performance and intelligence to the network edge in a flexible 1RU...
Страница 4: ...10 AWG wire with ring terminal for DC power supply 6 AWG wire for grounding Wire stripping tools for stripping 6 AWG copper wire Console cable PC with terminal emulation software Refer to the Initial...
Страница 5: ...S9110 32X width is 17 32 inches 44 0cm and shipped with a rack mount brackets suitable for 19 inch 43 8cm wide racks The depth of the S9110 32X chassis is 18 9 inches 48cm without the field replaceab...
Страница 6: ...40 to 75V DC 28A maximum x2 or AC version 100 to 240V 10A maximum x2 Installation spacing requirement S9110 32X spacing requires a height of 1RU 1 72 4 5cm a width of 19 48cm and a depth of 18 9 inch...
Страница 7: ...88x 43 x 20mm 2 pcs 0 37lb 170g 2pcs 0 19lb 85g pcs 4 Screw Kit for Rack Mount Bracket 8 x Screws M4 0 L6 5mm 1 set 0 02lb 7g set 5 Adjustable Mounting Rail for 4 posts 16 02 x 1 69 x 0 83 406 8 x 43...
Страница 8: ...2lbs 1 0kg AC PSU 2 6lbs 1 2kg Fan module 0 41lbs 185g Grounding lug kit 0 02lbs 10g Adjustable mounting rail 0 69lbs 315g USB 3 0 cable 0 04lbs 17 2g AC power cord AC version only 0 72lbs 325g RJ45...
Страница 9: ...S9110 32X Hardware Installation Guide 7 4 Identifying Your System S9110 32X System Overview Figure 5...
Страница 10: ...rflow identified with a blue latch The picture on the right is the DC PSU for front to back airflow identified with a red latch Back to Front Airflow PSU Front to Back Airflow PSU Figure 6 The DC powe...
Страница 11: ...rflow identified with a blue latch The picture on the right is the AC PSU for front to back airflow identified with a red latch Back to Front Airflow PSU Front to Back Airflow PSU Figure 8 The AC powe...
Страница 12: ...e top picture is for fans with back to front airflow identified with a blue handle The picture on the bottom is for the fans with front to back airflow identified with a red handle Back to Front Airfl...
Страница 13: ...ckets onto the router Align the rack mount brackets with the holes provided on the both sides of the case and secure the brackets using the 8 M4 0 L6 5mm screws provided with the package Figure 12 2 S...
Страница 14: ...come pre installed and the following steps are instructions on how to install a new fan module 1 Loosen the captive screw located on the fan module Figure 15 2 Grip the fan s handle and firmly pull i...
Страница 15: ...The process for removing and installing the PSUs are the same for all models DC AC Figure 18 Shock hazard For safety please disconnect all power inputs from the power supply unit before servicing the...
Страница 16: ...nd gently push until it is flush with the case 5 An audible click will be heard when the PSU is installed correctly The PSU will not go in all the way if it is in the wrong direction Illustrations are...
Страница 17: ...equipment must be grounded Do not defeat the ground conductor or operate the equipment without correctly grounding the equipment If there is any uncertainty about the integrity of the equipment s grou...
Страница 18: ...curing the grounding lug which is located on the side of the router and remove the protective label Figure 22 6 Using 2 M4 screws and 4 washers provided with the package contents firmly lock the groun...
Страница 19: ...2 Attach the power cable Locate the DC power screw type terminal block on the DC PSU Attach the UL 1015 10 AWG DC power cable not provided within the package contents to the DC inlet connector on the...
Страница 20: ...r designating normal operation AC Version 1 Ensure there is enough power to supply the system The maximum system power consumption is 565 watts with an input voltage of 100 240V AC It is recommended t...
Страница 21: ...ff No power Solid Green Host CPU BMC boot complete Solid Amber Power is up but Host CPU BMC boot failed FAN Off Fans are not initialized Solid Green All Fans are work normal Blinking Amber Fan fail on...
Страница 22: ...failure and or over temperature Blinking Red 1 sec Input power cord unplugged or input power lost with a second power supply in parallel still with AC input power Blinking between Green and Red Power...
Страница 23: ...RJ45 serial cable into the console port and connect the other end to the computer Cable types may vary depending on the model Figure 27 2 Check for serial control availability Disable any serial commu...
Страница 24: ...the USB Cable Connect the USB 3 0 A Type plug male connector into the USB port female connector located on the front panel of the router Figure 28 Connecting the OOB Management Cables Connect the OOB...
Страница 25: ...r optic cable and record its respective connection Maintain a clear line of sight to the port LEDs by routing the cables away from the LEDs Before connecting anything cables transceivers etc to the ro...
Страница 26: ...compromising stability Otherwise personal injury and or equipment damage may result Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in...
Страница 27: ...www ufispace com www ufispace com...