background image

REGISTER YOUR 

ANALYZER

BEFORE USING

Register within 30 Days of Purchase to

Get 

10% Off 

Your First Year Calibration

Keep up on the latest Accessories, Upgrades 

and Videos

Scan Now

 for Easy Online Registration    

or Visit www.ueitest.com

4
4
4

Содержание C164

Страница 1: ...YZER BEFORE USING Register within 30 Days of Purchase to Get 10 Off Your First Year Calibration Keep up on the latest Accessories Upgrades and Videos Scan Now for Easy Online Registration or Visit www ueitest com 4 4 4 ...

Страница 2: ...h built in magnets Log Print Temperature Screen Heat Exchange Integrity Test Screen LED Water Trap Indication Water Trap Window Flue Gas Inlet Connection Power button Display lines 1 through 6 Status bar line Navigation Pump T2 T1 T2 T1 P2 P1 C163 C164 Flue Test screens Auxiliary screen Status screen Menu screen USB charging port K type temperature inputs Pressure Ports C163 C164 only ...

Страница 3: ...Dial to STATUS to view parameters Selected Fuel Ti Ambient Temperature ATM Atmospheric Pressure measured in mbar CAL Days remaining until calibration Press and buttons to scroll Status Bar options Time Pump Status Battery Status Fuel Type Date Change Fuel Type in STATUS SCREEN Press and buttons to the currently selected fuel Press and Hold button until arrows indicate fuel edit mode is activated T...

Страница 4: ...mbustion Analyzer C163 CO C O 2 T E M P Flue 2 displays CO ppm CO2 Losses calculated Excess air Make any adjustments needed for proper Combustion and wait for analyzer to display change in readings Repeat as necessary BEFORE TESTING Remove the rubber boot and red drain plug Allow the water to drain out Re insert the rubber plug and replace boot cover Remove protective rubber boot Remove water trap...

Страница 5: ...P Combustion Analyzer C161 CO C O 2 T E M P STATUS F L U E 1 AUX FLUE 2 T E M P Combustion Analyzer C163 CO C O 2 T E M P STATUS F L U E 1 AUX FLUE 2 T E M P Combustion Analyzer C161 CO C O 2 T E M P AUX displays 5 lines of editable parameters To edit line values Press button until Edit displays on the Status Bar Press and Hold until the Status Bar reads LINE 1 When performing a combustion Test Ro...

Страница 6: ...Combustion Analyzer C161 CO C O 2 T E M P To print the LOG Press and buttons until PRINT is selected between two arrow icons Press to select to start printing STATUS F L U E 1 AUX FLUE 2 T E M P Combustion Analyzer C161 CO C O 2 T E M P To EXIT Press and buttons until EXIT is selected between two arrow icons Press to EXIT screen RepeatuntilreturntoMENUscreen STATUS F L U E 1 AUX FLUE 2 T E M P Com...

Страница 7: ...ranty and service information UEi Test Instruments 1 800 547 5740 info ueitest com This warranty gives you specific legal rights You may also have other rights which vary from state to state Download the full Owners Manual at UEiTEST COM or SCAN THIS CODE POST TESTING BATTERIES The analyzer is fitted with 3 AA size rechargeable batter ies Observe correct polarity when replacing Always check operat...

Страница 8: ... 12 Month warranty 2 Day turn around on all standard recertification services with pre approved payment Our recertification teams are factory certified and proud to provide industry leading turnaround support Our recertification centers in USA and Canada are ISO IEC 17025 2017 accredited facilities that only use EPA protocol test gases and can provide NIST certification ser vices Return freight pr...

Отзывы: