6
The C165 Combustion Analyzer measures CO, CO
2
, differential temperature and differential pressure .
CO
2
is set to zero in fresh air automatically after the initial countdown .
It is important that re-zeroing is done in outside fresh air as indoor CO
2
levels are affected by human breath .
It calculates oxygen (O
2
), CO/CO
2
ratio, Losses, Combustion Efficiency (Gross, Nett, Gross Condensing, or Nett Condensing) .
The C165 Combustion Analyzer can also measure CO levels in ambient air - useful when a CO Alarm is triggered . It can also perform a Room CO Test
for 30 minute duration .
A structured Commissioning Test has been included for the installation of boilers .
A low flow detection system warns of low flow and switches the pump off . This also helps to prevent water ingress from overfilled water traps .
The analyzer has a protective rubber boot with magnets for hands-free operation and is supplied with a probe with an integral temperature sensor .
A large 6 line display provides the user with relevant information . All data can be printed via the infrared printer or Wireless Printer App .
The C165 uses a new data storage system allowing the user to store the maximum number of logs of interest to them, rather than be restricted to an
allowance of particular logs .
The memory can store up to 30 logs of any combination of Combustion, AUX, Temperature, Heat Exchanger, Room CO, Commissioning tests .
OVERVIEW
www.calcert.com
1.800.544.2843