UEi 053533508215 Скачать руководство пользователя страница 1

INSTRUCTION MANUAL

ENGLISH

Smart Temperature Split Kit 
Smart Refrigerant Charging Kit 
Smart Refrigerant Complete Kit

HUB2 / HUB4 / HUB6

WPP1

Wireless Pressure

Probe

Power

Lo-Bat

WPP1
Wireless Pressure

Probe

Power

Lo-Bat

WHP1

Wireless 
Hygrometer Probe

WHP1: 

Wireless Hygrometer Probe

WPP1: 

Wireless Pressure Probe

WPC1: 

Pipe clamp sensor

UEI HUB APP

  

WARNING

Read entire safety notes section regarding potential hazard and proper 
instructions before using these probes. In this manual the word “

WARNING

” 

is used to indicate conditions or actions that may pose physical hazards to 
the user. The word “

CAUTION

” is used to indicate conditions or actions that 

may damage these instrument. 

  

WARNING

To ensure safe operation and service of these probes, follow these instructions. 
Failure to observe these warnings can result in severe injury or death.

  

WARNING

Maximum over pressure is: 1000 PSI.

  

WARNING

• Do not open these probes to replace batteries while the probes 

are connected to an HVACR or other mechanical system.

• To avoid false readings, replace batteries if a low battery indicator appears.  

• Do not use this these probes if  they appear damaged.

• Always adhere to national and local safety codes. Use proper personal

protective equipment (PPE).

 

WARNING

These probes are designed for trade professionals who are familiar with the 
hazards of their trade. Observe all recommended safety procedures that
include proper lockout utilization and use of personal protective equipment 
that includes safety glasses, gloves and flame resistant clothing.

HUB2

2 WHP1
4 Batteries (AAA)

Carrying case

HUB4

2 WPP1
2 WPC1
4 Batteries (AA)
Carrying case

HUB6

2 WHP1
2 WPP1
2 WPC1
8 Batteries 
(4x AA, 4x AAA)
Carrying case

IMPORTANT SAFETY WARNINGS

1.

 

Hygrometer (WHP1): Hub 2 & Hub 6

 A.

   Lock Button: Press to open or close probe 

 B

. 1/4” diameter probe.

 C.

Magnetic Mount

D.

Battery Cover.

 E

. Light: Blinks 

GREEN

 when probe is powered

on. Blinks 

RED

 when low battery.*

CAUTION:

 Press down Lock Button to

release probe. Failure to do so may break probe  
and is not covered under warranty.

GENERAL SPECIFICATIONS 

 

Operating Temperature:

 41°F to 140°F (5°C to 60°C)

Storage Temperature:

 14°F to 140°F (-10°C to 60°C)

Operating Humidity:

  20% RH to 80% RH  

Recommended: Do Not use longer than 60  
hours out of range

Dimensions: 

 6.84 in   x  1.93 in   x  1.53 in  

(17.4 cm x 4.9 cm x 3.9 cm)

Item Weight:

  4.4 oz (125 gr)

Certification: 

 CE Conformity, FCC/IC

Battery Type:  

(AAA)  2

Battery Life:

 100+ hours

* NOTE: 

Low battery indicator is also in the

“Tool Connection” screen

WHP1 OVERVIEW

WHP1

Wireless 
Hygrometer Probe

B.

A.

C.

E.

D.

Remove battery cover.

•   Replace the old batteries with 2 new 

(AAA) batteries.

Replace the battery cover.

Battery level 

are displayed in the  

tool connection screen to the right of each 
probe connected.

 

Caution

: Take care not to lose the screws 

when opening battery compartments

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание 053533508215

Страница 1: ...rve all recommended safety procedures that include proper lockout utilization and use of personal protective equipment that includes safety glasses gloves and flame resistant clothing HUB2 2 WHP1 4 Batteries AAA Carrying case HUB4 2 WPP1 2 WPC1 4 Batteries AA Carrying case HUB6 2 WHP1 2 WPP1 2 WPC1 8 Batteries 4x AA 4x AAA Carrying case IMPORTANT SAFETY WARNINGS 1 Hygrometer WHP1 Hub 2 Hub 6 A Lock...

Страница 2: ...B OVERVIEW B A A B C D E F WPP1 OVERVIEW WPC1 OVERVIEW A Suction Line Pressure B Suction Line Temperature C Refrigerant Favorites tap to view D Liquid Line Pressure E Liquid Line Temperature F Refrigerant List tap to view G Air Side Screen tap or swipe left to view H Vapor Saturation Temperature I Liquid Saturation Temperature A Refrigerant Side Screen tap or swipe right to view B Delta T C Target...

Страница 3: ... 215 1 PSI Drag tool here Drag tool here User Info Enter email address Enter name Enter phone number Save A D E F B C Units Pressure Temperature Enthalpy Altitude Compensation Elevation Units PSI F btu lb 1 ft bar KPa C Kj Kg ft m MPa B A C D E A Pressure Units B Temperature Units C Enthalpy Units D Elevation E Units A Tool Assigned B ForgetTool C Tool found but not assigned D Battery Level E Sign...

Страница 4: ...anada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication Conformément à la ...

Страница 5: ... el uso correcto del bloqueo de energía y el uso de equipo de protección personal que incluya lentes de seguridad guantes y ropa resistente al fuego HUB2 2 WHP1 4 Baterías AAA Estuche HUB4 2 WPP1 2 WPC1 4 Baterías AA Estuche HUB6 2 WHP1 2 WPP1 2 WPC1 8 Baterías 4 AA 4 AAA Estuche ADVERTENCIAS DE SEGURIDAD IMPORTANTES 1 Higrómetro WHP1 Hub 2 y Hub 6 A Botón de bloqueo presione para abrir o cer rar ...

Страница 6: ... A B C D E F INTRODUCCIÓN A WPP1 INTRODUCCIÓN A WPC1 A Presión de la línea de succión B Temperatura de la línea de succión C Sección de refrigerantes favoritos toque para ver D Presión de la línea de líquido E Temperatura de la línea de líquido F Lista de refrigerantes toque para ver G Pantalla del lado de aire toque o deslice hacialaizquierdapara ver H Temperatura de saturación de vapor I Tempera...

Страница 7: ...g tool here Drag tool here User Info Enter email address Enter name Enter phone number Save A D E F B C Units Pressure Temperature Enthalpy Altitude Compensation Elevation Units PSI F btu lb 1 ft bar KPa C Kj Kg ft m MPa B A C D E A Unidades de presión B Unidades de temperatura C Unidades de entalpía D Elevación E Unidades A Herramienta asignada B Olvidar herramienta C Herramienta encontrada pero ...

Страница 8: ... las instrucciones puede causar interferencia perjudicial a las comunicaciones de radio No obstante no hay garantía de que no ocurrirá interferencia en una instalación particular Si este equipo no causa interferencia perjudicial a la recepción de radio o televisión la cual se puede determinar al apagar y encender el equipo se recomienda al usuario tra tar de corregir la interferencia realizando un...

Страница 9: ...mandées y compris celles concernant le verrouillage approprié et utiliser un équipement de protection individuelle comprenant des lunettes de sécurité des gants et des vêtements ignifuges HUB2 2 WHP1 4 Piles AAA Étui de transport HUB4 2 WPP1 2 WPC1 4 Piles AA Étui de transport HUB6 2 WHP1 2 WPP1 2 WPC1 8 Piles 4x AA 4x AAA Étui de transport AVERTISSEMENTS DE SÉCURITÉ IMPORTANTS 1 Hygromètre WHP1 H...

Страница 10: ...APERÇU DU HUB UEi B A A B C D E F APERÇU WPP1 APERÇU WPC1 A Pression de conduite de succion B Température de conduite de suc cion C Favoris de réfrigérant toucher pour afficher D Pression de conduite du liquide E Température de conduite du liquide F Liste de réfrigérant toucher pour afficher G Écran côté air toucher ou balayer vers la gauchepour afficher H Température de saturation de vapeur I Tempér...

Страница 11: ...ere Drag tool here User Info Enter email address Enter name Enter phone number Save A D E F B C Units Pressure Temperature Enthalpy Altitude Compensation Elevation Units PSI F btu lb 1 ft bar KPa C Kj Kg ft m MPa B A C D E A Unités de pression B Unités de température C Unités Enthalpie Enthalpy D Élévation E Unités A Outil attribué B Oublier outil C Outil trouvé mais non attribué D Niveau de pile ...

Страница 12: ...unications radio Cependant il n y a aucune garantie que l interférence ne se produira pas dans une installation particulière Si cet équipement cause des interférences nuisibles à la réception radio ou de téléviseur ce qui peut être déterminé en arrêtant et en mettant en marche l équipement l utilisateur devrait essayer d éliminer l interférence par l une des mesures suivantes Réorienter ou reposit...

Отзывы: