background image

DC IN

LAN

AUDIO LINK

+24VDC

SPK

INPUT

TL

TL

MADE IN

SPAIN

IPU-1025

135,2

179,5

41,2

45,0

FRONT

SIDE

REAR

OUT

IN

OK

DEVICE

CALL

FAULT

CONFIG NET

ACTIVITY

USB

ON

IPU-1025

Engineered and made in E.U.

IPU-1025

4.1.-

4.2.-

INDEX

5

4

8

7

5

28

8

10

13

22

25

27

27

29

29

15

16

3

2

PAGE

1.- DESCRIPTION

2.- TECHNICAL DATA

3.- TYPICAL APPLICATION OF IPU-100

5.- DEVICE CONFIGURATION (WEBSERVER).

5.1.- Home page (HOME)

5.2.- SIP Configuration (SIP)

5.3.- Extension SIP Configuration (EXTENSIONS)

5.4.- Device configuration  (DEVICE)

5.5.- Network configuration LAN. (NETWORK)

5.9.-

(RESET TO FACTORY)

Reset to factory  default

5.10.- Remote Reboot (REBOOT)

5.3.1.- Erasing & editing

5.3.2.- P.A. zones edit page

Installation - Configuration - Use

IPU-1025

Audio over IP

5.6.- Time configuration (TIME).

5.7.- Date configuration (DATE).

5.8.- Password configuration device (PASSWORD).

4.- DESCRIPTION OF CONNECTIONS.

Front view.

Rear view.

AUDIO IP DECODER with 25W Class D AMPLIFIER

29

1

610.440A

rev.

1

EQUIPOS  Y  SISTEMAS  MEGAFONÍA / INTERCOM

PUBLIC  ADDRESS  SYSTEMS

[email protected]

BARCELONA - SPAIN

Tel.: +34 934 772 854  / +34 609 914 787

Содержание IPU-1025

Страница 1: ...tension SIP Configuration EXTENSIONS 5 4 Device configuration DEVICE 5 5 Network configuration LAN NETWORK 5 9 RESET TO FACTORY Reset to factory default 5 10 Remote Reboot REBOOT 5 3 1 Erasing editing 5 3 2 P A zones edit page Installation Configuration Use IPU 1025 Audio over IP 5 6 Time configuration TIME 5 7 Date configuration DATE 5 8 Password configuration device PASSWORD 4 DESCRIPTION OF CON...

Страница 2: ... network The decoder becomes the key element to ensure compatibility with all loudspeakers and horns trumpets on the PA portfolio of UNION DESARROLLOS ELECTRONICOS so that you can use to adapt older installations today Besides concentrating on just one set of IP decoder with built in amplifier allows savings in space power and price of the final device The IP system is suitable for any type of ins...

Страница 3: ...E FAULT System Clock Backup Supply 3V Lithium Battery CR2025 type Not rechargeable Audio Format Encoder Bandwidth Included Codec G 711 u Law 8 bits logarithmic compression and 8KHz sampling frequency G 711 a Law 8 bits logarithmic compression and 8KHz sampling frequency G 722 ADPCM 8 bits Adaptive Linear Compression and 16KHz sampling frequency PCM 16 bits without compression and 8KHz sampling fre...

Страница 4: ...pressandholdthebuttonof PTT Talk Inaddition theSIPserver whichactsasintermediarybetweenallIPdevicesconnectedtotheLANworking As can be seen our devices can connect to the wide range of speakers horns and trumpets of IPU 1025 IPU 1025 IPU 1025 IPU 1025 IPU 100 IPU 100P IPU 360 IP OUT IN OK DEVICE CALL FAULT CONFIG NET ACTIVITY USB ON Engineered and made in E U OUT IN OK DEVICE CALL FAULT CONFIG NET ...

Страница 5: ... network to the server to communicate with selected decoders The Call Out LED has not yet been activated communication is not established The IPU 360 processes and sends packets with information to the IPU 100 that communication begins feasible At this time the CALL OUT LED turns ON This indication remains active until the user releases the call button At which the IPU 1025 reports to the installa...

Страница 6: ...esh thestatusoftheIPU 360server TheIPU 1025automaticallyexecutesaregistrationattempttotheserverconfiguredinitssettingsandeverytimeyourestorethepowerwillalso run the connection attempt During the process the device remains without registration with the IPU 360 server the DEVICE FAULT LED is RED indicating that there is a connection problem with the server so the device is not operating temporarily ...

Страница 7: ...ty to power it with 12V of phantom power activated from the Webserver Activation when there is a microphone or background music source can be done with Activation by closing remote input to the ground terminal Activation by detecting audio signal modulation With an ASYMETRIC connection make a short between MIC and 0V GND This euroblock connector is the audio output from the incoming call via IP ne...

Страница 8: ...fault on computers where you can access unqualified personnel to modify the settings of IP equipment ListofavailableMenus This area displays the menu selection icons that the user can select for your device configuration When the user selects a different menu to the HOME or Main will be asked to enter a password If the password is right and match any of the previously stored will thenopenthedesire...

Страница 9: ...s and outputs StatusMonitor LEDsstatus Activationsignalstatus Sensorlevelstatus Inthisareayoucanseethreezones Itshowsinrealtimethestatus on off flashing ofallindicatorspresentonthefrontpanel Showsthestateoftheactivationsignalsofdifferentbasicfunctionssuchas VOXactivated MICactivated etc It shows the voltage measurement of the sensors included on the device 24V Adaptor 24V Backup Battery VOX signal...

Страница 10: ...public address characteristics the codifiers and decodersrequiresadditionalinformationinsidethestandardizeddatagram ChooseONtousetheUDEPAsignalinginformation IncaseofpriorityorIPU 100Pinstallations theboxmuststayinONoption Incaseof100 SIPstandardcomplianceOFFoption Defines the IP address where the SIP server host It is required that the address contains the 12 numbers along with the 3 breakpoints ...

Страница 11: ... with the IPU 360 SIP server The standard default value in the device is 05060 you should keep to ensure compatibility with different SIP servers Remember to always use a configuration with 5 digits Example Local Port Defines the data transmission UDP port Voice INFO used by the IPU 360 SIP server to communicate with the IPU 1025 The standard default value is 00000 automatic mode you should keep t...

Страница 12: ...max number of priorities consulttheIPU 360datasheet The must be configured with audio sources like MP3 players or Microphones like PZ 40 for Music on holdcalls Itisadifferentpriorityfromthe thatonlyconcernsdeskcontrolmicrophones These characteristics give tools to program de PAsystem over IP if the IPU 1025 is linked with an IPU 100P desk control a priority desk can be applied This priority must b...

Страница 13: ...5 3 EXTENSIONSIPCONFIGURATION ONLYIPU 100Pmode ThepublicaddresszoneconfigurationwithanIPU 100PdeskcontrolmustbedonewithaIPU 1025codifier Itisnotpossibletomakethe desk control configuration with the touch screen The extension web server of the IPU 1025 menu will allow erasing all IPU 100P zone buttonsoreditingthePAbuttonsoftheIPU 100Pdeskcontrol 5 DEVICE CONFIGURATION WEBSERVER 610 440A Installatio...

Страница 14: ...the whole desk control memory 2 Editing zones keeping the zones configuration The main page have 10 PA buttons and navigation icons Each button zone can be edited with a description text and numbers of zones to call decoders The maximum number of PA zones will be a totally broadcast message for all the zones configured in the IPU 360 SIP server 5 DEVICE CONFIGURATION WEBSERVER 610 440A Installatio...

Страница 15: ...to erase all data The IPU 100P screen while the erase process is execute will keep out of work for any paging call Also a deleting data message will be printedtogiveuserinformation Zoneeditpage Whentheerase process has finished thewebpagewill beredirected tothezone edit webpage also thetouch screen oftheIPU 100Pwill work Deleting data Please Wait 18 12 Caution The erasing process is irreversible i...

Страница 16: ...eleftmenuandclick If you did the erase memory process you will be redirected to the PA zones edit page of the IPU 100P The zone edit page has two main areas one is the general navigation and edition of the buttons that already exist in the desk control IPU 100P andanother areaallowseditingonespecificbutton addingthelabelandthedifferentextensionsthatwillcall 5 DEVICE CONFIGURATION WEBSERVER IPU 102...

Страница 17: ... 1300 typing 300 and clicking the new number appears in the extension Validate Senddata Whenallextensions labelsandbuttonsareready clickon Thisactionmustbedoneeverytimeonebuttonisedited Extensionconfiguration To enter the extensions in a button the configuration must be done one by one extension that is enter one extension send the informationandsuccessivelyforalltheextensiontobeinonebutton Furthe...

Страница 18: ...Numberofextensiontocallbythebutton Clickon BOTTON3 Yard 1003 1004 1010 Button3edition Typenewlabel Send data Buttonname Extensiontocall Numberofextensiontocallbythebutton Clickon Zone 1 1001 Main room 002 Yard IPU 100P Paging Desk Zone 1 1 00 00 1001 Main room 002 Yard 003 003 ZONE EDIT PAGE Without any data inside the system the webpage should look like Edition of button 1 First extension to conf...

Страница 19: ...001 appears in the extension box In button number one has only one extension to call 1001 there is no other extension to configure and configuration must be uploaded Click on button BUTTON 1 EDITION 1001 Button 1 configuration has been saved and screen shows the new button IPU 100P Paging Desk Zona 1 1 00 00 1001 5 DEVICE CONFIGURATION WEBSERVER 610 440A Installation Configuration Use IPU 1025 IPU...

Страница 20: ...xtension to call 002 equal to 1002 Confirm extension with Extension 1002 appears in the extension box Type the second extension to call in button 2 this is extension 400 equal to 1400 Confirm extension with Extension 1400 appears in the extension box In button number two has only two extensions to call 1002 1400 there is no other extension to configure and configuration must be uploaded Click on b...

Страница 21: ...n 1003 appears in the extension box Type the second extension to call in button 3 this is extension 004 equal to 1004 Confirm extension with Extension 1004 appears in the extension box Type the second extension to call in button 3 this is extension 010 equal to 1010 Confirm extension with Extension 1010 appears in the extension box In button number three has three extensions to call 1003 1004 and ...

Страница 22: ...ou to receive IP calls with the difference that when it receive no IP calls then IPU 1025 will amplify the audio signal present at the INPUT connector MIC LINE Attention Do not use the IPU 100P Mode when no IP Paging Desk is connected to the AUDIO LINK terminal as it can lock the IPU 1025 temporarily until you perform a reboot of the device VoIP Codec G 711 u Law G 711 a Law G 722 ADPCM Allows sel...

Страница 23: ... the time it will spend in the detected signal condition before being made the audio streaming activationcall Alwaysusea3 digitformat Example Select between 000 and 120 seconds the time it will spend in the no signal condition before being canceled the audio streaming call Alwaysusea3 digitformat Example Selectstheminimumthresholdfordetectingtheaudiosignalasactive Alwaysusea3 digitformat minimum1 ...

Страница 24: ...urationparametercanonlybeusedinIPU 100Pmode Alwaysusea3 digitformat Example mín max Select between 010 and 128 the gain level to be applied to audio from the external microphone of the desk control IPU 100P connected to the IPU 1025 CM 23 is the recommended microphone This configuration parameter can only be used in IPU 100Pmode Alwaysusea3 digitformat Example mín max Therearefewinputcalls dependi...

Страница 25: ...gserviced Example HostName NETBIOS HostNamepordefectodefábrica 1 NETBIOS Restriction 15 alphanumeric characters with basic punctuation characters period hyphen underscore andNOspaces 5 5 CONFIGURATIONLAN Network ThissectiondescribeshowtosetNETWORKconfigurationparametersbasictoanylocalareanetwork LAN Followthestepsbelow EnableLANchanges When this option is unchecked the status of the current connec...

Страница 26: ...use of your device then assign it a null address 000 000 000 000 or simply leaves it blank ExampleofvalidAlternativeDNS PrimaryDNSIP PrimaryDNSIPbyFactorydefault AlternativeDNS oSecondary format XXX XXX XXX XXX 000 000 000 000 Defines the address of the device on the local area network or external that will allow you to connect to other computers in the world through URLs in case the Primary DNS d...

Страница 27: ...E Entertheday monthandyeardesired consideringalwaysuse2digitsformat Clickon toupdatethesystemcalendar 29 27 Alwaysusetheformat dd mm yy Example Day dd 20 Month mm 01 Year yy 13 Alwaysusetheformat hh mm ss Example Hour hh 22 Minute mm 45 Seconds ss 55 5 DEVICE CONFIGURATION WEBSERVER IPU 1025 IPU 1025 610 440A Installation Configuration Use IPU 1025 IPU 1025 Rev 1 ...

Страница 28: ...racterswithASCIIbetween32and127 8alphanumericcharacterswithASCIIbetween32and127 8alphanumericcharacterswithASCIIbetween32and127 Confirmpassword 29 28 IPU 100 Attention The new password will take effect only if the old password has been entered correctly and has not been wrong to confirm the new password The system will reset to the new password take effect 5 DEVICE CONFIGURATION WEBSERVER IPU 1025...

Страница 29: ...T The IPU 1025 can be remote rebooted just click to the icon on the left menu and confirm clicking on icon 29 29 Caution The erasing process is irreversible in case of error the memory information cannot be recovered 5 DEVICE CONFIGURATION WEBSERVER IPU 1025 IPU 1025 IPU 1025 610 440A Installation Configuration Use IPU 1025 IPU 1025 Rev 1 ...

Отзывы: