ERROR MESSAGE
Too Dirty Fiber
It is displayed when the fiber prepared
for splice is contaminated more than
normal status.
HOW TO
· Reset the fiber after cleaning.
Replace The Fiber In The
Correct Position
It is displayed when the fiber is not
placed in the middle of the electrodes
and V�groove or the objective lenses
or reflection mirror is contaminated.
HOW TO
· Press and place the fiber
in the middle of the electrodes
and V�groove.
· Check the condition of the lenses
and reflectionmirror and remove
any dirt.
Too Long Fiber
It is displayed when the fiber is
placed too close to the electrode, the
lenses or reflection mirror is dirty or
LED light is not bright enough.
HOW TO
· Press and place the fiber
again.
· Remove dust and dirt from the
lenses and reflection mirror.
· Conduct an LED test. If an error
occurs, contact UCLSWIFT Co., Ltd
RESET
RESET