MENU
Non Editable
Non Editable
Editable
Non Editable
Editable
Editable
The arc can be adjusted by two steps.
The first step is [arc�] and second is [arc�].
[arc�] is set here.
Arc� Power
Arc� Time
t sets the time of [arc�].
It is the second step of arc. [arc�] is set here.
Arc� Power
Non Editable
Editable
It sets the time of [arc�]. In general, [arc� time]
is set to “OFF”. It is possible to set a very long
arc time; however, if the [arc� time] and [arc�
time] is longer than �� seconds, the electrode
can be damaged.
Arc� Time
Non Editable
Editable
It sets arc to ON and OFF alternatively while the
[arc�] is performing arc discharge. The duration
of [arc�] operating time is set here. Arc discharge
time ON has to be set always in order to conduct
re-arc.
Arc� On-Time
Editable
Editable
Arc� Off-Time
· It sets the re-arc time.
· It automatically sets the re-arc to discharge
the same amount as [Arc �] in [Splice Mode Edit].
If arc � is set to ON and OFF, the re-arc is automati
cally set to ON and OFF as well.