Ublox SARA-R5 Series Скачать руководство пользователя страница 11

EVK-R5 - User guide 

UBX-19042592 - R06 

Starting up

  

Page 11 of 23 

C1-Public 

 

 

1.7

 

Board setup 

1.

 

Insert a SIM card into the 

SIM card holder

 (J300 on the EVB-WL3). 

2.

 

Connect the cellular antenna provided with the evaluation kit box to the 

Cellular antenna

 SMA 

connector on the ADP-R5 (ANT connector for transmission and reception of LTE RF signals). 

3.

 

If the GNSS functionality is required: 
3.1.

 

For  the  EVK-R500S  and  EVK-R510S,  connect  the  GNSS  antenna  provided  with  the 
evaluation kit box to the 

GNSS antenna 

SMA connector on the ADP-GNSS (J208); keep 

cellular GNSS detach switch (SW304) i

n “GNSS” position

3.2.

 

For the EVK-R510M8S, connect the GNSS antenna provided with the evaluation kit box to 
the 

GNSS antenna 

SMA connector on the ADP-R510M8S (J112); keep cellular GNSS detach 

switch (SW304) i

n “detach” position

Place the GNSS antenna in a location with a good view of the sky. 

4.

 

Connect the AC / DC +12 V power adapter provided with the evaluation kit box to the 

 18 V 

power input

 connector (J400 on the EVB-WL3). The LED DL401 lights blue. 

5.

 

Be  sure  to  provide  a  jumper  socket  on  both  the 

Cellular  VCC  supply  jumpers

  (J404  on  the 

EVB-WL3, and J109 on the ADP-R5). These jumpers provide the connection from the 3.8 V output 
of the supply circuit on the EVB-WL3 to the VCC input of the module. 

6.

 

To enable the board power supply, turn the 

Main power switch

 (SW400 on the EVB-WL3) to the 

ON position. The LED DL400 lights green. 
6.1.

 

For  the  EVK-R510S,  press  the 

Cellular  power-on

  button  (SW302  on  the  EVB-WL3)  to 

switch on the SARA-R510S cellular module. 

6.2.

 

For the EVK-R500S, the SARA-R500S cellular module switches on. For the EVK-R510M8S, 
the SARA-R510M8S cellular module switches on. 

7.

 

For  communicat

ion  via  the  cellular  module’s  UART  interface,  the  following  connections  are 

allowed and can be alternatively enabled in a mutually exclusive way (see 

Table 6

 for the switch 

position and LED status): 
7.1.

 

Connect a USB cable to the mini USB connector on EVB-WL3 (

Cellular USB

, J501). The LED 

DL501 lights blue. When a USB cable is connected to this mini USB connector, two COM 
ports are enabled in Windows: the single UART interface of the cellular module (with default 
USIO variant 0, or USIO variant 1) is available over the first COM port opened by the driver. 

7.2.

 

Connect an RS232 cable to the DB9 connector on EVB-WL3 (

Cellular RS232

, J500). 

7.3.

 

Connect a USB cable to the mini USB connector on ADP-R5 (

Cellular USB

, J201). The LED 

DS201 lights blue. When a USB cable is connected to this mini USB connector, two COM 
ports are enabled in Windows: the two UART interfaces of the cellular module (with UART 
variant 2, 3, or 4) are respectively available over the two numbered COM ports opened by 
the driver. 

Type of connections 

USIO variant  

SW401 

SW403 

LED 

Access to cellular single UART interface (USIO variant 0 or 1) 
over the 

Cellular USB 

mini USB connector on EVB-WL3 (J501) 

0 (default) / 1 

ON BOARD  MINIUSB 

DL403 

Access to cellular single UART interface (USIO variant 0 or 1) 
over the 

Cellular RS232 

DB9 connector on EVB-WL3 (J500) 

0 (default) / 1 

ON BOARD  DB9 

DL405 

Access to cellular two UART interfaces (USIO variant 2, 3 or 4) 
over the 

Cellular USB 

mini USB connector on ADP-R5 (J201) 

2 / 3 / 4 

B2B 

Do not care  DL404, 

DS202 

Table 6: Serial interface configuration 

Содержание SARA-R5 Series

Страница 1: ...llular evaluation kits User guide Abstract This guide explains how to set up the EVK R5 evaluation kits to begin evaluating the u blox SARA R5 series modules supporting multi band LTE M NB IoT cellula...

Страница 2: ...roduct specification This document applies to the following products Product name Type number Modem version Application version PCN reference Product status EVK R500S EVK R500S 0 00 02 05 A00 01 UBX 2...

Страница 3: ...al communication 13 B Setting up cellular packet data connection on Windows 14 B 1 Install a new modem from the control panel 14 B 2 Configuring a new connection 16 C AT commands examples 17 C 1 Defin...

Страница 4: ...1 8 V Power input J400 Cellular adapter board DL400 Main power switch SW400 DL401 SARA R5 cellular module DIL B2B connector J300 DIL B2B connector J301 GND GNSS antenna connector RF_IN J208 GNSS modul...

Страница 5: ...module and the DIL header connectors J300 and J301 making the interfaces of the SARA R5 module accessible 3 The GNSS adapter board called ADP GNSS contains the u blox GNSS module the GNSS antenna conn...

Страница 6: ...r module SW302 EVB WL3 Cellular reset Push button to reset the cellular module SW303 EVB WL3 Cellular UART detach Slide switch to attach detach the cellular module single UART from the USB RS232 conne...

Страница 7: ...ta on the Cellular RS232 connector DL405 EVB WL3 Cellular RI indicator RI line turns ON active low DS501 EVB WL3 Cellular CTS indicator CTS line turns ON active low DS500 EVB WL3 Cellular GPIO1 indica...

Страница 8: ...5 module SMA connector for the GNSS antenna to be connected to the GNSS RF input of the SARA R5 module ANT_GNSS 3 J112 ADP R5 Cellular native USB Mini USB connector for the cellular module native USB...

Страница 9: ...vailable 15 PWR_ON J301 pin 30 47 SDIO_D0 Not available 16 GPIO1 J301 pin 34 48 SDIO_D3 Not available 17 VUSB_DET Not available 49 SDIO_D1 Not available 18 RESET_N J300 pin 25 50 GND J301 pins 7 10 19...

Страница 10: ...D Not connected 25 26 GPIO4 RESET_N 25 26 I2S_WA Not connected 27 28 Not connected Not connected 27 28 Not connected Not connected 29 30 PWR_ON Not connected 29 30 Not connected GPIO3 31 32 GPIO2 Not...

Страница 11: ...R510S cellular module 6 2 For the EVK R500S the SARA R500S cellular module switches on For the EVK R510M8S the SARA R510M8S cellular module switches on 7 For communication via the cellular module s U...

Страница 12: ...401 according to Table 6 the module can be switched on again Run an AT terminal application e g the u blox m center tool selecting an AT port with these settings o Data rate 115 200 bit s o Data bits...

Страница 13: ...es described in section 1 7 Check the Windows Device Manager to find out which COM port is being used by the EVK R5 Figure 3 Home page 4 Enable the connection to the u blox cellular module by clicking...

Страница 14: ...cket data connection on Windows 10 using the operating system s TCP IP stack and EVK R5 This is also referred to as a dial up connection B 1 Install a new modem from the control panel 1 Open the Contr...

Страница 15: ...inish to complete the modem installation 6 Now the new modem is visible under the Modems tab in Control Panel Phone and Modem Any extra initialization AT command e g to set a specific APN name can be...

Страница 16: ...ly installed 4 Enter the parameters for the dial up connection o The module telephone number 99 1 to be changed if using a PDP context different from 1 o The specific account information for the netwo...

Страница 17: ...ch bearer AT COPS 0 OK CEREG 1 0001 01a2d001 7 CGEV ME PDN ACT 1 Trigger a network registration and wait for attach complete C 2 Data connection using internal TCP IP stack Activate an internal contex...

Страница 18: ...nal context profile_id 0 Map a context with protocol type IPV4V6 AT CGDCONT 1 IPV4V6 default OK Set context cid 1 with IPV4V6 protocol type and APN string default wait for context cid 1 activation AT...

Страница 19: ...network AT CEREG CEREG 0 1 OK Verify the network registration status AT COPS 0 OK Register the module on the network The cellular module automatically registers itself on the cellular network This co...

Страница 20: ...meter placed in series as illustrated in Figure 6 SARA R5 adapter board SARA R5 Cellular module 42 pin DIL B2B connectors EVB WL3 Step down Main power switch SW400 12 V J400 3 8 V VCC jumper J109 VCC...

Страница 21: ...al Purpose Input Output HW Hardware I2C Inter Integrated Circuit I2S Inter IC Sound IoT Internet of Things IP Internet Protocol LED Light Emitting Diode LTE Long Term Evolution N A Not Applicable NB N...

Страница 22: ...x documentation and to receive product change notifications register on our homepage www u blox com Revision history Revision Date Name Comments R01 22 Oct 2019 fvid Initial release R02 11 Nov 2019 lp...

Страница 23: ...al Office China Beijing Phone 86 10 68 133 545 E mail info_cn u blox com Support support_cn u blox com Regional Office China Chongqing Phone 86 23 6815 1588 E mail info_cn u blox com Support support_c...

Отзывы: