10.19 Escape prompt delay (EPD) S12
S12
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M
Modules
SARA-N4
Syntax
PIN required
Settings saved Can be aborted
Response time Error reference
Attributes
partial
No
No
No
-
10.19.1 Description
Defines the maximum period, in fiftieths of a second, allowed between the reception of the last character of
the sequence of three escape characters from the DTE and the sending of the OK result code to the DTE. If any
characters are detected during this time, the OK will not be sent.
Furthermore, the timeout is:
• The minimum period, before the first character reception of the three escape character sequence, during
which no other character must be detected to accept it as a valid first character
• The maximum period allowed between receipt of first, or second, character of the three escape character
sequence and receipt of the next
• The minimum period, after the last character reception of the three escape character sequence, during
which no other character must be detected to accept the escape sequence as a valid one
10.19.2 Syntax
Type
Syntax
Response
Example
Set
ATS12=<value>
OK
ATS12=80
OK
Read
ATS12?
<value>
OK
050
OK
10.19.3 Defined values
Parameter
Type
Description
<value>
Number
Range 0 - 255. The answer to the read command is in "xxx" format. The default value
is 50 (1 s)
10.20 Command echo E
E
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M
Modules
SARA-N4
Syntax
PIN required
Settings saved Can be aborted
Response time Error reference
Attributes
full
No
No
-
10.20.1 Description
Controls whether or not the MT echoes characters received from the DTE during command state.
10.20.2 Syntax
Type
Syntax
Response
Example
Set
ATE[<value>]
OK
ATE1
OK
10.20.3 Defined values
Parameter
Type
Description
<value>
Number
•
0: echo off
•