LISA-U series - System Integration Manual
UBX-13001118 - R17
Advance information
System description
Page 76 of 190
1.9.3
USB interface
LISA-U modules provide a high-speed USB interface at 480 Mb/s compliant with the
Universal Serial Bus Revision
[8]. It acts as a USB device and can be connected to any USB host such as a PC or other
Application Processor.
The USB-device shall look for all upper-SW-layers like any other serial device. This means that LISA-U modules
emulate all serial control logical lines.
Name
Description
Remarks
VUSB_DET
USB detect input
Apply 5 V typical to enable USB
USB_D+
USB Data Line D+
90
Ω
nominal differential characteristic impedance (Z
0
)
30
Ω
nominal common mode characteristic impedance (Z
CM
)
Pull-up or pull-down resistors and external series resistors as
required by the
USB 2.0 high-speed specification
[8] are part
of the USB pad driver and need not be provided externally.
USB_D-
USB Data Line D-
90
Ω
nominal differential characteristic impedance (Z
0
)
30
Ω
nominal common mode characteristic impedance (Z
CM
)
Pull-up or pull-down resistors and external series resistors as
required by the
USB 2.0 high-speed specification
[8] are part
of the USB pad driver and need not be provided externally.
Table 34: USB pins
The USB interface pins ESD sensitivity rating is 1 kV (Human Body Model according to JESD22-A114F).
Higher protection level could be required if the lines are externally accessible on the application board.
Higher protection level can be achieved by mounting a very low capacitance (i.e. less or equal to 1 pF) ESD
protection (e.g. Tyco Electronics PESD0402-140 ESD protection device) on the lines connected to these
pins, close to accessible points.
1.9.3.1
USB features
LISA-U2 modules include a High-Speed USB 2.0 compliant interface with maximum data rate of 480 Mb/s
between the module and a host processor.
The module itself acts as a USB device and can be connected to any USB host such as a Personal Computer or an
embedded application microprocessor for AT commands, data communication, FW upgrade by means of the
FOAT feature, FW upgrade by means of the u-blox EasyFlash tool and for diagnostic purpose.
The
USB_D+
/
USB_D-
lines carry the USB serial bus data and signaling, while the
VUSB_DET
input pin senses
the VBUS USB supply presence (nominally +5 V at the source) to detect the host connection and enable the
interface.
The USB interface of the module is enabled only if a valid voltage is detected by the
VUSB_DET
input (see the
LISA–U1 series Data Sheet
[1] and
[2]). Neither the USB interface, nor the whole
module is supplied by the
VUSB_DET
input: the
VUSB_DET
senses the USB supply voltage and absorbs few
microamperes.
LISA-U series modules can provide the following functions over the USB interface:
CDC-ACM for AT commands and data communication
CDC-ACM for GNSS tunneling
CDC-ACM for diagnostic
CDC-ACM for SAP (SIM Access Profile)
CDC-ECM for Ethernet-over-USB
CDC-ECM for Ethernet-over-USB function is not supported by “x0”, “x1” and “x2” product versions.