Scope 

This document defines the essential specifications necessary to implement the JODY-W1 antenna 

reference  designs.  It is  part of  the  equipment certification  application  issued  to  FCC and  IC.  The 

information contained herein and its references should be sufficient to guide a skilled person in an 

attempt  to  implement  the  design  on  a  host  carrier.  It  will  provide  the  designer  with  PCB  layout 

details and expected performance specifications. 
The document supports a connector-based designs for the use of external antennas (one for each 

antenna pin of the module) 

2

 

FCC/IC ID reference 

Model 

FCC ID 

IC ID 

JODY-W164-03A 

XPYJODYW164 

8595A-JODYW164 

JODY-W164-07A 

XPYJODYW164-07A 

8595A- JODYW16407A 

Table 1: FCC and IC IDs for different models of JODY-W1 series 

3

 

General description and requirements 

JODY-W1 series module provides three RF interfaces for connecting the external antennas. 

Antenna ports ANT0 and ANT1 have a nominal characteristic impedance of 50 

 and must be 

connected to the related antenna through a 50 

 transmission line to allow proper impedance 

matching along the RF path; a bad termination of the pin may result in poor performance or even 

damage to the RF section of the module. 
The ANT2 antenna port is not used on the JODY-W164-03A and JODY-W164-07A modules. 
For optimal antenna performance in multi-radio mode, the isolation between the antennas must be 

maximized; the designer must follow the requirements specified in Table 2 and Table 3 to ensure 

good performance. 