Appendix 

A

 

Setting up AT terminal applications for 
communication with EVK-U2x 

 
The  u-blox  m-center  cellular  module  evaluation  tool  is  a  powerful  platform  for  evaluating,  configuring  and 
testing u-blox cellular modules. m-center includes an AT commands terminal for communication with the device 
and can be downloaded free-of-charge from our website (http://www.u-blox.com). 
 

1.

 

Follow the board setup instructions in section 1.8 to provide all the required connections and switching on 
the cellular module. 

2.

 

Run the m-center tool: after the m-center start-up, the 

Home

 page appears. 

3.

 

On the 

Home

 page, set up the AT COM port; for 

the setting values see section 1.8. 

Check with Windows Device Manager to find out 
which COM port is being used by EVK-U2x. 

 

Figure 3: m-center Home page 

 

4.

 

Enable the connection to u-blox cellular module by 
clicking on the 

Connect

 button. 

 

5.

 

Retrieve  the  module  and  network  information  by 
clicking on the 

Get Info

 button. 

 

6.

 

The module information is retrieved and displayed 
on the 

Home

 page. 

 

7.

 

Click  on  the 

AT  Terminal

  button,  found  at  the 

upper  right  of  the 

Home

  page.  A  new  window 

opens and the AT command terminal is now ready 
for communication with EVK-U2x. 

 

 

Figure 4: AT Terminal window 

8.

 

The AT terminal is ready to use. 

For  the  complete  list  of  AT  commands  supported 
by the modules and their syntax, see the 

u-blox AT 

Commands Manual 

[1]. 

For more information on using the m-center tool, 
see the 

m-center User Guide

 [4]. 

 

Содержание EVK-U201SARA

Страница 1: ...uation kit User Guide Abstract This guide explains how to set up the EVK U201SARA EVK U26 and EVK U27 Evaluation Kits to begin evaluating the u blox SARA U2 series HSPA UMTS EGPRS GSM cellular modules...

Страница 2: ...EVK U26 00S 02 23 41 A01 01 UBX 15020745 EVK U27 EVK U27 00S 01 23 20 A01 01 UBX 16006754 EVK U27 00S 02 23 41 A01 01 UBX 15020745 u blox reserves all rights to this document and the information conta...

Страница 3: ...dix 11 A Setting up AT terminal applications for communication with EVK U2x 11 B Setting up cellular packet data connection on PC 12 B 1 How to install and configure a low data rate modem connection 1...

Страница 4: ...rted EVK U2x can also be used to evaluate other SARA U2 series modules as SARA U280 See the SARA U2 series Data Sheet 2 and SARA G3 SARA U2 series System Integration Manual 3 for the features supporte...

Страница 5: ...ng female connectors provided on top of the lower board The USB interface of the cellular module is available on the native USB connector on the cellular adapter board while the other peripherals are...

Страница 6: ...ended period of time Caution Risk of explosion if battery is replaced with an incorrect type Dispose of used batteries according to the instructions 1 5 LEDs Function Description LED Board Color Main...

Страница 7: ...able Not available VUSB_DET 17 48 RSVD Not available J100 Pin 26 RESET_N 18 47 RSVD Not available J103 Pin 24 CODEC_CLK 19 46 RSVD Not available J103 Pins 7 8 9 10 GND 20 45 RSVD Not available J103 Pi...

Страница 8: ...COM ports are enabled in Windows the numbering of the COM ports can be seen via the Windows Device Manager The serial port for AT commands is available over the first numbered COM port opened by the d...

Страница 9: ...3 on EVB if the audio functionality is required 1 9 Enabling verbose error result codes Command sent by DTE user DCE response module Description AT CMEE 2 OK Enables the cellular module to report verb...

Страница 10: ...ubsequent re boot of the module with the execution of the following actions Set module CODEC_CLK pin to provide 13 MHz master clock to the external Maxim MAX9860 audio codec mounted on EVK U2x Open th...

Страница 11: ...the Home page set up the AT COM port for the setting values see section 1 8 Check with Windows Device Manager to find out which COM port is being used by EVK U2x Figure 3 m center Home page 4 Enable t...

Страница 12: ...ver the native USB interface of the cellular module connected to the Windows PC by the Cellular Native USB connector J313 on ADP B 1 How to install and configure a low data rate modem connection This...

Страница 13: ...odem Properties 7 Select Change Settings Advanced 8 Add APN settings command APN shown is just an example Make sure to have the correct APN defined by the network operator 9 Click on Change Default Pr...

Страница 14: ...r dial up connection The module telephone number 99 1 The specific GPRS account information for the network operator A name for the new connection e g u blox GPRS Connection 14 The packet data connect...

Страница 15: ...m using the TCP IP stack of the PC over the native USB interface of the cellular module connected to the Windows PC by the Cellular Native USB connector J313 on ADP 1 Follow the board setup instructio...

Страница 16: ...lox Modem USB1 AT and Data X X 7 in the picture 5 Enter the modem telephone number 99 1 select Allow other people to use this connection and click Connect to finalize the procedure Consult the cellula...

Страница 17: ...eadset Hang up Outgoing voice call Command sent by DTE user DCE response module Description AT CLIP 1 OK Activation of caller line ID presentation ATD 3930012345678 OK Outgoing voice call 393001234567...

Страница 18: ...ice 1 attached 0 detached AT CGDCONT 1 IP uni tim it OK Define the PDP context parameters AT CGDCONT CGDCONT 1 IP my apn 0 0 0 0 0 0 OK ATD 99 1 CONNECT Initiate the GPRS connection NO CARRIER Disconn...

Страница 19: ...T UGGLL 1 OK Enable the GLL message AT UGGLL UGGLL state GLL msg OK Or UGGLL state Not Available OK Read the message The last available GLL message is displayed C 8 GNSS AssistNow GNSS AssistNow Onlin...

Страница 20: ...nds Manual Docu No UBX 13002752 2 u blox SARA U2 series Data Sheet Docu No UBX 13005287 3 u blox SARA G3 SARA U2 series System Integration Manual Docu No UBX 13000995 4 u blox m center User Guide Docu...

Страница 21: ...rt support_ap u blox com Regional Office China Beijing Phone 86 10 68 133 545 E mail info_cn u blox com Support support_cn u blox com Regional Office China Chongqing Phone 86 23 6815 1588 E mail info_...

Страница 22: ...D5821AEBZ EVAL AD7175 8SDZ EVAL AD7262EDZ EVAL AD7265EDZ EVAL AD7366SDZ EVAL AD7634EDZ EVAL AD7641EDZ EVAL AD7655EDZ EVAL AD7674EDZ EVAL AD7705EBZ EVAL AD7718EBZ EVAL AD7719EBZ EVAL AD7730LEBZ EVAL AD...

Отзывы: