EVK-F9P-01 - User guide
UBX-22038408 - R03
Specifications
Page 6 of 28
C1- Public
2
Specifications
Parameter
Specification
Serial interfaces
1 USB Type-C
1 RS232, max baud rate 230,400 Baud
DB9 +/- 12 V level
14 pin – 3.3 V logic
1 DDC (I2C compatible) max 400 kHz
1 SPI – clock signal max 5,5 MHz – SPI DATA max 1 Mbit/s
Timing interfaces
1 timepulse output through 14-pin connector
1 timepulse LED
1 timepulse output through RS232
1 external interrupt input
Dimensions
105 x 64 x 26 mm
Power supply
5 V via USB or powered via external power supply pin 14
(V5_IN) and pin 13 (GND)
Normal operating temperature
-40 °C to +65 °C
Table 2: EVK-F9P specifications
2.1
Safety precautions
EVK-F9P must be supplied by a PS1 class limited power source. See section 6.2.2.4 of IEC 62368-
1:2018 [
] for more information on the PS1 class.
In addition to a limited power source, only ES1 class circuits are to be connected to the EVK-F9P,
including interfaces and antennas. See section 5.2.1.1 of IEC 62368-1:2018 [
] for more information
on the ES1 class.
2.1.1
Certifications
The EVK-F9P is designed to comply with the essential requirements and other relevant provisions of
Radio Equipment Directive (RED) 2014/53/EU.
The EVK-F9P complies with the Directive 2011/65/EU (EU RoHS 2) and its amendment Directive (EU)
2015/863 (EU RoHS 3).