Safety Notices

1.  Read, follow, and keep these instructions.
2.  Heed all warnings.
3.  Only use attachments/accessories specified by the manufacturer.

WARNING:

 Do not use this product in location that can 

be submerged by water. 

WARNING:

 Avoid using this product during an electrical 

storm. There may be a remote risk of electric shock from 
lightning. 

Electrical Safety Information

1.  Compliance is required with respect to voltage, frequency, and current 

requirements indicated on the manufacturer’s label. Connection to a 
different power source than those specified may result in improper 
operation, damage to the equipment or pose a fire hazard if the 
limitations are not followed.

2.  There are no operator serviceable parts inside this equipment. Service 

should be provided only by a qualified service technician.

3.  This equipment is provided with a detachable power cord which has 

an integral safety ground wire intended for connection to a grounded 
safety outlet.
a.  Do not substitute the power cord with one that is not the provided 

approved type. Never use an adapter plug to connect to a 2-wire 
outlet as this will defeat the continuity of the grounding wire. 

b.  The equipment requires the use of the ground wire as a part of the 

safety certification, modification or misuse can provide a shock 
hazard that can result in serious injury or death.

c.  Contact a qualified electrician or the manufacturer if there 

are questions about the installation prior to connecting the 
equipment.

d.  Protective earthing is provided by Listed AC adapter. Building 

installation shall provide appropriate short-circuit backup 
protection.

e.  Protective bonding must be installed in accordance with local 

national wiring rules and regulations.

                    Available from A1 Security Cameras 

    www.a1securitycameras.com email: [email protected]

Содержание PowerBeam PBE-5AC-400-ISO-US

Страница 1: ...5 GHz airMAX Bridge with 300 mm RF Isolated Reflector Model PBE M5 300 ISO Available from A1 Security Cameras w a1securitycameras com email sales a1securitycamera...

Страница 2: ...solated Reflector Model PBE M5 300 ISO PoE Adapter 24V 0 5A with Mounting Bracket Power Cord Quick Start Guide TERMS OF USE Ubiquiti radio devices must be professionally installed Shielded Ethernet ca...

Страница 3: ...le Door Rear Housing Antenna Feed Ethernet Port Release Button Slot Mounting Bracket Release Button Reflector Alignment Pins Reset Button Radome Available from A1 Security Cameras w a1securitycameras...

Страница 4: ...In airOS you can modify the wireless signal strength threshold values for each LED on the Advanced tab under Signal LED Thresholds The default values are shown below LED will light green when the wir...

Страница 5: ...lation Requirements 13 mm wrench Shielded Category 5 or above cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the PoE We recommend that you pr...

Страница 6: ...counter clockwise until the alignment holes in the dish and bracket align with each other 2 Line up the Alignment Pins of the Rear Housing with the alignment holes of the Mounting Bracket Push the Re...

Страница 7: ...ith the inner wall of the Reflector and locked into place Important Before proceeding lightly pull the Rear Housing to confirm that it is locked into place 4 Push in the sides of the Cable Door and de...

Страница 8: ...ull the Antenna Feed to ensure that it is locked into place and the Release Button is fully engaged Release Button Bottom View 6 Connect an Ethernet cable to the Ethernet Port of the Antenna Feed Then...

Страница 9: ...e Bolts through the holes of the Adjustment Bracket c Slide the hole of the Pole Clamp over one bolt of the Adjustment Bracket d Place one Flange Nut on each bolt Elevation Indicator Slot 8 Secure the...

Страница 10: ...e pole b Slide the slot of the Pole Clamp over the Carriage Bolt c Tighten the Flange Nuts of the bolts to 25 N m to secure the antenna to the pole 25 N m Note The mounting assembly can accommodate a...

Страница 11: ...dome Guide the Radome s side and top tabs over the Reflector rim and slide the Radome down onto the Reflector Arrow Notch Radome Top Tab Radome Side Tab Radome Side Tab Reflector Rim Available from A1...

Страница 12: ...n angle a Loosen the four Hex Bolts on both sides of the antenna b Pivot the antenna until the Hash Mark in the Elevation Indicator Slot points to the desired elevation angle c Tighten the four Hex Bo...

Страница 13: ...at the desired location and mark the two holes 2 Pre drill the holes if necessary and secure the bracket using two fasteners not included 3 Align the adapter s slots with the tabs of the Mounting Bra...

Страница 14: ...will appear Enter ubnt in the Username and Password fields Select your Country and Language You must agree to the Terms of Use to use the product Click Login Note U S product versions are locked to t...

Страница 15: ...c Click Change to save d Click OK to confirm Customize additional settings as needed to complete the configuration For additional details on the airOS Configuration Interface refer to the User Guide...

Страница 16: ...is operated within local country regulatory requirements Since Ubiquiti Networks equipment can be paired with a variety of antennas and cables the Antenna and Output Power fields are provided to the p...

Страница 17: ...ed Plastic Max Power Consumption 6W Power Supply 24V 0 5A PoE Adapter Included Power Method Passive PoE Pairs 4 5 7 8 Return Wind Survivability 200 km h 125 mph Wind Loading 210 N 200 km h 47 lbf 125...

Страница 18: ...an 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one th...

Страница 19: ...nce abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged or impaired as a result of using third party firmware VI has no original Ubiquiti...

Страница 20: ...AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS DELAYS CANCELLATIONS DELIVERY FAILURES DATA LOSS CONTENT CORRUPTION PACKET LOSS OR OTHER DAMAGE RESULTING FROM ANY OF...

Страница 21: ...ding interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits a...

Страница 22: ...ation of the device This radio transmitter IC 6545A NBM5HP has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna im...

Страница 23: ...ovide a separation distance of at least 20 cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter Les antennes utilis es pour ce transmetteur doi...

Страница 24: ...uct Deutsch Die Europ ische Richtlinie 2002 96 EC verlangt dass technische Ausr stung die direkt am Ger t und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Geme...

Страница 25: ...ctronique par les moyens de collecte indiqu s par le gouvernement et les pouvoirs publics des collectivit s territoriales L limination et le recyclage en bonne et due forme ont pour but de lutter cont...

Страница 26: ...irektiivin 1999 5 EY Fran ais French Par la pr sente UBIQUITI NETWORKS d clare que l appareil UBIQUITI NETWORKS est conforme aux exigences essentielles et aux autres dispositions pertinentes de la dir...

Страница 27: ...skrav och vriga relevanta best mmelser som framg r av direktiv 1999 5 EG Espa ol Spanish Por medio de la presente UBIQUITI NETWORKS declara que este dispositivo UBIQUITI NETWORKS cumple con los requis...

Страница 28: ...OS InnerFeed PowerBeam and TOUGHCable are trademarks or registered trademarks of Ubiquiti Networks Inc in the United States and in other countries All other trademarks are the property of their respec...

Отзывы: