Страница 1: ...10 GHz Carrier Class airMAX BaseStation with Dish Antenna Model PBM10 ...

Страница 2: ...feed M4x12 Screw and Washer Assembly Qty 4 M4x18 Screw and Washer Assembly Qty 4 M10 Hex Nuts Qty 9 M16 Hex Nuts Qty 2 M10 Washers Qty 9 M16 Washers Qty 2 10 GHz Carrier Class airMAX BaseStation with Dish Antenna Model PBM 10 M10 Washers Qty 9 M16 Washers Qty 2 PoE Adapter 24V 1A Power Cord Quick Start Guide TERMS OF USE Ubiquiti radio devices must be professionally installed Shielded Ethernet cab...

Страница 3: ...ould be grounded through the AC ground of the PoE We recommend that you protect your networks from the most brutal environments and devastating ESD attacks with industrial grade shielded Ethernet cable from Ubiquiti Networks For more details visit www ubnt com toughcable Hardware Installation To install the PowerBridgeM10 perform the following steps 1 Align the Radio to the back of the Dish ...

Страница 4: ...2 On the front of the Dish use the four M4x18 Screw and Washer Assemblies to secure the Radio to the Dish ...

Страница 5: ...sing a M10x25 Bolt a M10 Washer a M10 Spring Lock Washer and a M10 Hex Nut Install a M16 Hex Nut about halfway down on the Elevation Rod and then install a M16 Washer on the Elevation Rod 4 Insert the four M10x150 Carriage Bolts into the Mounting Bracket ...

Страница 6: ...ting Bracket and through the Dish The bolts should be on the inside facing outward b Secure each bolt using a M10 Washer a M10 Spring Lock Washer and a M10 Hex Nut c Slide the Mounting Bracket onto the Elevation Rod d Secure the Mounting Bracket to the Elevation Rod using a M16 Washer a M16 Spring Lock Washer and a M16 Hex Nut ...

Страница 7: ...pressing down and raising it up Connect an Ethernet cable to the Radio and place the cover back on the Radio There is an opening for the Ethernet cable Slide the cover over the cable 7 Make sure the O Ring is secure on the Feed O Ring ...

Страница 8: ...nstallation of the Dish to the pole Always hold the Dish or the brackets while installing the product 9 Attach the Stabilizer Brackets to the pole just beneath the area where the Dish will be attached Use two M10x100 Bolts two M10 Washers two M10 Spring Lock Washers and two M10 Hex Nuts Tighten the nuts to approximately 50 N m 37 lb ft Note The mounting assembly can accommodate a Ø 1 5 4 0 pole ...

Страница 9: ...10 Place the Pole Clamps on the other side of the pole that the Dish will be mounted on and connect them to the Mounting Bracket using M10 Washers M10 Spring Lock Washers and M10 Hex Nuts ...

Страница 10: ... the stabilizer bracket Elevation is adjusted by loosening the Elevation Rod Tighten all bolts and nuts to approximately 50 N m 37 lb ft or less to avoid deforming the pole Elevation Azimuth 12 Connect the other end of the Ethernet cable from the Radio to the Ethernet port labeled POE on the PoE Adapter ...

Страница 11: ...ect an Ethernet cable from your LAN to the Ethernet port labeled LAN on the PoE Adapter 14 Connect the power cord to the power port on the PoE Adapter Connect the other end of the power cord to a power outlet ...

Страница 12: ... field and press enter PC or return Mac 4 The login screen will appear Enter ubnt in the Username and Password fields Select your Country and Language You must agree to the Terms of Use to use the product Click Login Note U S product versions are locked to the U S Country Code to ensure compliance with FCC regulations The airOS Configuration Interface will appear allowing you to customize your set...

Страница 13: ...sponsibility to make sure the device is operated within local country regulatory requirements Since Ubiquiti Networks equipment can be paired with a variety of antennas and cables the Antenna Gain Cable Loss and Output Power fields are provided to the professional installer to assist in meeting regulatory requirements ...

Страница 14: ... of your link 2 In the airOS Configuration Interface of the PowerBridgeM10 activate the Frequency Scan List option and click the Edit button 3 Select the free channel and save your changes 4 Follow the same steps 1 3 for your second PowerBridgeM10 at the other end of the link 5 Check the Fresnel zone this must be free 6 In the airOS Configuration Interface of the PowerBridgeM10 use the Speed Test ...

Страница 15: ...r Method Passive Power over Ethernet Pairs 4 5 7 8 Return Operating Temperature 40 to 80 C Operating Humidity 5 to 95 Condensing Shock and Vibration ETSI300 019 1 4 PowerBridgeM10 Dish Antenna Characteristics Dimensions 648 x 648 mm Weight 9 8 kg Frequency 10 322 GHz 10 574 GHz Gain 33 0 34 4 dBi HPOL Beamwidth 3 0 3 7 over Band VPOL Beamwidth 3 0 3 7 over Band F B Ratio 33 dB Max VSWR 1 4 1 Wind ...

Страница 16: ...provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug to connect to a 2 wire outlet as this will defeat the continuity of the grounding wire b The...

Страница 17: ... has been subjected to misuse abuse negligence abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged or impaired as a result of using third party firmware or VI has no original Ubiquiti MAC label or is missing any other original Ubiquiti label s VII has not been received by Ubiquiti within 30 days of issuance of the RMA In addition the ab...

Страница 18: ... FACILITIES UBIQUITI NETWORKS ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS DELAYS CANCELLATIONS DELIVERY FAILURES DATA LOSS CONTENT CORRUPTION PACKET LOSS OR OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING In addition UBIQUITI NETWORKS does not warrant that the operation of the Products will be error free or that operation will be uninterrupted ...

Страница 19: ...xpressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipmen...

Страница 20: ...nication réussie Cet appareil est conforme à la norme RSS Industrie Canada exempts de licence norme s Son fonctionnement est soumis aux deux conditions suivantes 1 Cet appareil ne peut pas provoquer d interférences et 2 Cet appareil doit accepter toute interférence y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif RF Exposure Warning The antennas used for this ...

Страница 21: ...detailed in formation about the disposal of your old equipmen t please con tact your local authorities waste disposal service or the shop where you purchased the product Deutsch Die Europäische Richtlin ie 2002 96 EC verlan gt dass techn ische Ausrüstun g die direkt am Gerät un d oder an der Verpackun g mit diesem Symbol versehen ist n icht zusammen mit un sortiertem Gemein deabfall en tsorgt werd...

Страница 22: ...nsi que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d élimination de votre ...

Страница 23: ...õhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele Suomi Finnish UBIQUITI NETWORKS vakuuttaa täten että UBIQUITI NETWORKS device tyyppinen laite on direktiivin 1999 5 EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen Français French Par la présente UBIQUITI NETWORKS déclare que l appareil UBIQUITI NETWORKS device est conforme aux exige...

Страница 24: ... etky príslu né ustanovenia Smernice 1999 5 ES Svenska Swedish Härmed intygar UBIQUITI NETWORKS att denna UBIQUITI NETWORKS device står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999 5 EG Español Spanish Por medio de la presente UBIQUITI NETWORKS declara que el UBIQUITI NETWORKS device cumple con los requisitos esenciales y cualesq...

Отзывы: